Product specifications
This document highlights the features and specifications for the SAN24B-6 switch.
System specifications
| System component | Description |
|---|---|
Enclosure |
1U, nonport-side intake airflow, port-side power inlet |
Power inlet |
C13; power from port side |
Power supplies |
Single, fixed power supply |
Fans |
Four built-in fans |
Cooling |
Nonport-side to the port side |
System architecture |
Nonblocking shared memory switch |
System processors |
Freescale T1022E CPU |
Port-to-port latency |
<900 nanoseconds with no contention (destination port is free) including FEC using cut-through frame switching. |
Fibre Channel
| System component | Description |
|---|---|
Fibre Channel ports |
24 SFP+ ports (8-port increments through capacity-based Ports on Demand (PoD) licenses) that support any combination of Short Wavelength (SWL) and Long Wavelength (LWL) or Extended Long Wavelength (ELWL) optical media. The SFP+ ports are capable
of auto-negotiating to 4, 8, 16, or 32 Gbps speed depending on the
SFP+ model and the minimum supported speed of the optical transceiver
at the other end of the link.
Note: 2-, 4-, and 8-Gbps transceivers are not supported.
|
ANSI Fibre Channel protocol |
Fibre Channel Physical and Signaling Interface standard (FC-PH) |
Modes of operation |
Fibre Channel Class 2 and Class 3 |
Fabric initialization |
Complies with FC-SW-3 Rev. 6.6 |
FCIP (IP over Fibre Channel) |
Complies with FC-IP 2.3 of FCA profile |
Port Status |
Bicolor LED (amber/green) |
Other
| System component | Description |
|---|---|
Serial console port |
One three-wire (Tx, Rx, Gnd) UART serial port |
Ethernet management port |
One 1000/100/10 Base-T port |
USB port |
One external USB port |
LEDs
| System component | Description |
|---|---|
System power LED |
One green system power status LED (upper) on the left side. |
System status LED |
One bicolor (green/amber) system status LED (lower) on the left side. |
Ethernet port link LED |
One link LED on the left of the RJ45 connector. This glows green for 1000 Mbps and amber for 100/10 Mbps. |
Ethernet port activity LED |
One green activity LED on the right of the RJ45 connector. |
FC port status LED |
24 bicolor (green/amber) port status LEDs. There is one LED for each SFP+ port on the switch. |
Weight and physical dimensions
Empty weight refers to the device with built-in power supply and fan assemblies but no SFP+ or QSFP transceivers.
| Height | Width | Depth | Weight (empty) | Weight (fully loaded) |
|---|---|---|---|---|
4.29 cm 1.69 inches |
42.88 cm 16.88 inches |
30.64 cm 12.06 inches |
4.2 kg 9.30 lb |
5.75 kg 12.65 lb |
Environmental requirements
| Condition | Operational | Non-operational |
|---|---|---|
Ambient temperature |
0°C to 40°C (32°F to 104°F) |
-25°C to 70°C (-13°F to 158°F) |
Relative humidity (non-condensing) |
10% to 85% at 40°C (104°F) |
10% to 90% (Non-condensing) |
Altitude (above sea level) |
0 to 3000 m (9,842 feet) |
0 to 12000 m (39,370 feet) |
Shock |
20.0 G, 6 ms, half-sine wave |
33.0 G, 11 ms, half-sine wave, 3G Axis |
Vibration |
0.5 G sine, 0.4 gms random, 5 – 500 Hz |
2.0 G sine, 1.1 gms random, 5 – 500 Hz |
Airflow |
Maximum: 54.5 cmh (32.1 cfm) Nominal: 36.35 cmh (21.4 cfm) |
N/A |
Heat dissipation |
Refer to the Power consumption sections. |
N/A |
Operating noise |
Maximum: 64 dBA Normal: 57 dBA |
N/A |
Power supply specifications
| Maximum output power rating (DC) | Input voltage | Input line frequency | Maximum input current | Maximum inrush current |
|---|---|---|---|---|
150 W |
100 – 240 VAC (nominal) 90 – 264 VAC (range) |
50/60 Hz (nominal) 47 – 63 Hz (range) |
2.2 A |
50 A |
Power consumption (typical configuration)
| @100 VAC input | @200 VAC input | @48 VDC input | Notes |
|---|---|---|---|
0.62 A 63.15 W 215.54 BTU/hr |
0.33 A 61.40 W 209.56 BTU/hr |
N/A |
Fully configured all ports with 25% traffic rate, max port speed at 32G, fans at nominal speed, and input power +/- 5% tolerance. |
Power consumption (maximum configuration)
| @100 VAC input | @200 VAC input | @48 VDC input | Notes |
|---|---|---|---|
0.75 A 76.52 W 261.17 BTU/hr |
0.39 A 74.40 W 253.93 BTU/hr |
N/A |
Fully configured all ports with 100% traffic rate, max port speed at 32G, fans at high speed, and input power +/- 5% tolerance. |
Power consumption (idle configuration)
| @100 VAC input | @200 VAC input | @48 VDC input | Notes |
|---|---|---|---|
0.55 A 55.83 W 190.55 BTU/hr |
0.30 A 54.30 W 185.33 BTU/hr |
N/A |
All optics loaded but not initialized and the system completed boot up, fans at nominal speed, and input power +/- 5% tolerance. |
Data port specifications (Fibre Channel)
| Port Numbers | Media Type | Description |
|---|---|---|
0 to 23 |
16- or 32-Gbps SFP+ optical ports |
Switch mode (default): 8-, 16-, and 24-port configurations (8-port increments through Ports on Demand [PoD] licenses); can be an F_Port, N_Port, or E_Port. Access Gateway default port mapping: 16 F_Ports, 8 N_Ports. |
Fibre Channel data transmission ranges
| Port speed (Gbps) | Cable size (microns) | Short wavelength (SWL) | Long wavelength (LWL) | Extended long wavelength (ELWL) |
|---|---|---|---|---|
4 |
50 |
150 m (492 ft) (OM2) 380 m (1,264 ft) (OM3) 400 m (1,312 ft) (OM4) |
N/A |
N/A |
62.5 |
70 m (229 ft) |
N/A |
N/A |
|
9 |
N/A |
30 km (18.6 miles) |
N/A |
|
8 |
50 |
50 m (164 ft) (OM2) 150 m (492 ft) (OM3) 190 m (623 ft) (OM4) |
N/A |
N/A |
62.5 |
21 m (68 ft) |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) 25 km (15.5 miles) |
N/A |
|
16 |
50 |
35 m (115 ft) (OM2) 100 m (328 ft) (OM3) 125 m (410 ft) (OM4) |
N/A |
N/A |
62.5 |
15 m (49 ft) |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) 25 km (15.5 miles) |
N/A |
|
32 |
50 |
70 m (230 ft) (OM3) 100 m (328 ft) (OM4) |
N/A |
N/A |
62.5 |
N/A |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) |
N/A |
Serial port specifications (pinout RJ-45)
| Pin | Signal | Description |
|---|---|---|
1 |
Not supported |
N/A |
2 |
Not supported |
N/A |
3 |
UART1_TXD |
Transmit data |
4 |
GND |
Logic ground |
5 |
GND |
Logic ground |
6 |
UART1_RXD |
Receive data |
7 |
Not supported |
N/A |
8 |
Not supported |
N/A |
Serial port specifications (protocol)
| Parameter | Value |
|---|---|
Baud |
9600 |
Data bits |
8 |
Parity |
None |
Flow control |
None (must be disabled at the host) |
Stop bits |
1 |
Memory specifications
| Memory | Type | Size |
|---|---|---|
Main Memory |
DDR3L SDRAM with 8-bit ECC, SORDIMM package, operating at 1200 MT/s |
2 GB, 64-bit |
Boot Flash |
Parallel NOR flash embedded memory |
8 MB |
eUSB Module |
- |
2 GB |
Regulatory compliance (EMC)
- FCC Part 15, Subpart B
- EN 55024
- EN 55032
- ICES-003
- VCCI
- EN 300 386
- CNS 13438
- KN 32
- KN 35
- TCVN 7189 / TCVN 7317
- EN 61000-3-2
- EN 61000-3-3
- 51318.24-99
- GB 9254
- CISPR 22
- 2014/30/EU
Regulatory compliance (safety)
- EN/UL 60825
- EN/UL/CSA/IEC 60950-1
- GB 4943.1
- CNS 14336-1
- 2014/35/EU
- 51318.22-99
Regulatory compliance (environmental)
- 2014/35/EU and 2014/30/EU
- 2011/65/EU - Restriction of the use of certain hazardous substance in electrical and electronic equipment (EU RoHS).
- 2012/19/EU - Waste electrical and electronic equipment (EU WEEE).
- 94/62/EC - packaging and packaging waste (EU).
- 2006/66/EC - batteries and accumulators and waste batteries and accumulators (EU battery directive).
- 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (EU REACH).
- Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act of 2010 - U.S. Conflict Minerals.
- 30/2011/TT-BCT - Vietnam circular.
- SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China).
- SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China).