Use the following procedures to
remove a faulty drive from the enclosure and replace it with a new one from stock. The procedures are also applicable when you are removing or
replacing an IBM FlashCore® Module.
Before you begin
Attention:
When you replace this part, you must follow recommended procedures for handling
electrostatic discharge (ESD)-sensitive devices.
No tools are required to complete this task. Do not remove or loosen any screws.
You can identify the failed drive by the flashing amber fault LED on the drive carrier. If the
fault LED is lit on a drive, it is safe to replace the drive.
If you are not sure which drive is
faulty, go to the management GUI and follow the
fix procedures to prevent loss of data or access to data. If an incorrect part is removed, it is
possible to lose access to data.
Every drive slot of an operational control enclosure must contain either a drive or a blank
filler, and must not be left empty for more than 10 minutes during servicing. Ensure that you read
and understand the instructions. Also, ensure that the replacement drive is available and unpacked
before you remove the existing drive.
IBM
FlashCore Modules are not interchangeable with the flash modules that are used in IBM® Storage FlashSystem 900 storage
enclosures.
The version of firmware on the replacement
drive might not be the latest drive firmware available, and might not match the firmware version of
other drives in the system. If necessary, firmware on the replacement drive can be updated after
this procedure is complete.
Each drive slot of an operational control enclosure must contain a drive or a blank filler.
Read the safety precautions in the IBM Systems Safety Notices. These guidelines
help you safely work with the system.
Removing the drive
Press the blue touchpoint to unlock the latching handle, as shown in this figure.
Figure 1. Unlocking the drive and release latch
Lower the handle and slide the drive out of the enclosure, as shown in this figure.
Figure 2. Removing the drive
Replacing the drive
Ensure that the LED indicators are at the top of the drive.
Press the blue touchpoint to unlock the latching handle on the new drive.
Slide the new drive into the node canister, as
shown in this figure. Press on the drive label near the bottom of the drive to ensure that the
drive is fully inserted into the slot.
Figure 3. Inserting the new drive
Finish inserting the new drive by closing the handle until the latch clicks into place.
Figure 4. Completing the drive installation
Results
If the failed drive was a member of an array and sufficient members of the array are online,
the system automatically updates array membership. The system rebuilds the array to include the
replacement drive.
After
insertion, the drive firmware is automatically updated if the current firmware level is down‑level
compared to the version included in the system software package. For more information, see
Drive update.