After you install all hardware components, you must power on the system and check its
status.
About this task
Attention: Do not power on the system with any open bays or slots. Open bays or slots
disrupt the internal air flow, causing the drives to receive insufficient cooling.
- Every unused drive bay must be occupied by a filler panel.
- Filler panels must be installed in all empty host interface adapter slots.
Procedure
To power on the system, complete the following steps.
- Wait for all expansion
enclosures to finish powering on.
- Power on
the control enclosure. Use the supplied power cords to connect all of the power supply units of the
enclosure to their power sources.
If the power sources have circuit breakers or switches, ensure that they are turned on. The
enclosure does not have power switches.
Notes:
- Each enclosure has
two power supply units. To provide power failure redundancy, connect the two power cords to separate
power circuits.
- Ensure that each power cable is secured to each PSU on the back of the enclosure.
What to do next
Next, you will connect an Ethernet cable to the technician port on the control enclosure,
and initialize the system.