3930Grid orchestration is paused due to configuration error.
Explanation
This error indicates a configuration related validation failure for any member
system. Check the event attached to this validation failure to identify the exact configuration
error in the FlashSystem grid.
Event ID 053008
This event is raised if the FlashSystem grid configuration
operation is paused due to incompatible software version on the member system.
Event ID 053009
This event is raised if another coordinator system is detected in the FlashSystem grid.
User response
For event ID 053008
Upgrade the system to a software version that supports FlashSystem grid configuration. The
event gets automatically resolved after the upgrade.
For event ID 053009
Wait until the FlashSystem grid
orchestration stabilizes with the newer configuration. The error event gets fixed when the new
coordinator system details, such as owner epoch and owner
uuid, are updated on the old coordinator.
Run the -leave option of the managegrid command on the old coordinator system to exit from the FlashSystem grid to fix the error
event.