3930 Grid orchestration is paused due to configuration error.

Explanation

This error indicates a configuration related validation failure for any member system. Check the event attached to this validation failure to identify the exact configuration error in the FlashSystem grid.
Event ID 053008
This event is raised if the FlashSystem grid configuration operation is paused due to incompatible software version on the member system.
Event ID 053009
This event is raised if another coordinator system is detected in the FlashSystem grid.

User response

For event ID 053008
Upgrade the system to a software version that supports FlashSystem grid configuration. The event gets automatically resolved after the upgrade.
For event ID 053009
  • Wait until the FlashSystem grid orchestration stabilizes with the newer configuration. The error event gets fixed when the new coordinator system details, such as owner epoch and owner uuid, are updated on the old coordinator.
  • Run the -leave option of the managegrid command on the old coordinator system to exit from the FlashSystem grid to fix the error event.