1630 The number of device logins was reduced.
Explanation
The number of port-to-port fabric connections, or logins, between the node and a storage controller decreased. This situation might be caused by a problem on the SAN or by a deliberate reconfiguration of the SAN.
The 1630 error code is reported for a number of different error IDs. The error ID indicates more specifics about the problem. The data that is reported in an event log entry indicates where the condition was found.
010045 Number of Device paths from the controller site allowed accessible nodes has reduced
- The controller now has fewer logins from the controller site that allocated accessible nodes to the storage controller.
- The error data indicates the WWNN or IP address of the disk controller, and the current path count from each node.
- A controller fault or a Fibre Channel network fabric fault might cause this condition.
User response
- Check the error in the cluster event log to identify the object ID associated with the error.
- Check
the availability of the failing device by using the following command: lscontroller
object_ID. If the command fails with the message
CMMVC6014E The command failed because the requested object is either unavailable or does not exist,
ask the customer if this device was removed from the system.- If
yes
, mark the error as fixed in the cluster event log and continue with the repair verification procedure. - If
no
or if the command lists details of the failing controller, continue with the next step.
- If
- Check whether the device regained connectivity. If it has not, check the cable connection to the remote-device port.
- If all attempts to log in to a remote-device port failed and you cannot solve the problem by changing cables, check the condition of the remote-device port and the condition of the remote device.
- Start a cluster discovery operation by rescanning the Fibre Channel network.
- Check the status of the disk controller. If all disk controllers show a
good
status, mark the error that you repaired asfixed
. If any disk controllers do not showgood
status, start the fix procedure from the event log menu in the GUI. If you return to this step, contact the support center to resolve the problem with the disk controller. - Run the fix procedure from the event log menu in the GUI.
Possible Cause-FRUs or other:
- None
Other:
- Fibre Channel network fabric fault (50%)
- Enclosure or controller fault (50%)