1053 Internal SAS connector failure, service action required.
Explanation
An error occurred involving an internal SAS connector. Any of the following alerts might be
associated with this error code.
- 045116 SAS connector to an enclosure secondary expander module is not working at full capacity
- 045117 SAS connector to an enclosure secondary expander module is offline
- 045118 The state of an enclosure secondary expander module connector cannot be determined
User response
Complete the following steps:
- Enable maintenance mode for the I/O group.
- Slide the enclosure out of the rack sufficiently to open the access lid.
- Reseat the affected secondary expander module (SEM).
- If the error does not clear, reseat the canister on the side of the affected SEM.
- If the error does not clear, replace the affected SEM.
- If the error does not clear, replace the canister on the side of the affected SEM.
- If the error does not clear, contact your service support representative. You might need to replace the enclosure.