Removing the top cover

To complete some service tasks, you might need to remove the top cover from a 5U expansion enclosure.

Before you begin

Important: You can remove the cover without powering off the expansion enclosure. However, to maintain operating temperature, replace the cover within 15 minutes of its removal. When the cover is removed, the reduction in airflow through the enclosure might cause the enclosure or its components to shut down to protect from overheating.

Procedure

  1. Use the slide rails to pull the enclosure out from the rack.
  2. Slide the release latch ( 1 ) in the direction that is shown in Figure 1.
    Figure 1. Releasing the 5U expansion enclosure cover
    Releasing the 5U expansion enclosure cover
  3. Slide the cover toward the front of the expansion enclosure ( 2 ), as shown in Figure 1.
  4. Carefully lift the cover up, as shown in Figure 2.
    Figure 2. Removing the 5U expansion enclosure cover
    Removing the the 5U expansion enclosure cover
  5. Place the cover in a safe location.

Replace the cover

  1. To reinstall the cover, or replace it with one from FRU stock, follow the procedure in Installing or replacing the top cover.