Removing a secondary expander module

You can remove a secondary expander module from a 5U expansion enclosure if it is faulty or to perform other service tasks.

Before you begin

DANGER
Safety icon for voltage
Hazardous voltage present. Voltages present constitute a shock hazard, which can cause severe injury or death. (L004)
DANGER
Safety icon for voltage
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in splattered metal, burns, or both. (L005)
CAUTION:
  • Only an IBM Service Support Representative (SSR) can remove or replace the secondary expander module from an enclosure (FRU P/N 01LJ112) that is powered on. If the 01LJ112 enclosure is powered on, use caution and avoid contact with the connectors on the main board.
  • If the FRU part number of the enclosure is 01LJ607, you can remove or replace the secondary expander module while the enclosure is powered on.
Important: You can remove a secondary expander module without powering off the expansion enclosure. However, to maintain operating temperature, perform the following tasks.
  • Do not remove a faulty secondary expander module until its replacement is ready to be installed.
  • Do not keep the cover off an operational enclosure for more than 15 minutes. The reduction in airflow through the enclosure might cause the enclosure or its components to shut down to protect from overheating.

About this task

The secondary expander modules provide SAS connectivity between the expansion canisters and the drives. Each drive has 2 SAS ports. SAS port 1 of each drive is connected to secondary expander module 1. SAS port 2 of each drive is connected to secondary expander module 2. Each expansion canister is connected to both secondary expander module 1 and secondary expander module 2. If secondary expander module 2 is missing or is faulty, the expansion canisters can communicate only with SAS port 1 on each drive. Similarly, if secondary expander module 1 is missing or is faulty, the expansion canisters can communicate only with SAS port 2 on each drive.

The two secondary expansion modules are already installed when the 5U expansion enclosure is shipped, as Figure 1 shows.
Figure 1. Location of secondary expander modules
Location of secondary expander modules
Figure 2 shows the location of the LED indicators on the top of the secondary expander module. Each secondary expander module has its own set of LEDs. When power is connected to the expansion enclosure, the LEDs identify the operational status of the secondary expander modules.
Figure 2. Location of LEDs on the secondary expander module
LEDs on the secondary expander module
Table 1 describes the function and status values of each LED indicator.
Table 1. LEDs on the secondary expander modules
LED Color Status Description
Power  1  Green On The secondary expander module is receiving power.
Off The secondary expander module is not receiving power.
Fault  2  Amber On Not used.
Blink The secondary expander module is being identified.
Off Normal operation.
This task assumes that the following conditions were met:

Procedure

  1. Identify the secondary expander module to be replaced; refer to Table 1.
  2. Press the release buttons on top of the secondary expander module to release the handles.
  3. Rotate the handles outward to the unlocked position.
  4. Lift the secondary expander module carefully out of the enclosure, as shown in Figure 3.
    Figure 3. Remove the secondary expander module
    Remove the secondary expander module
    Important: To avoid electric shock after you remove the secondary expander module, do not touch the connectors inside the enclosure (FRU P/N 01LJ112), which are shown in Figure 4.
    Figure 4. Secondary expander module connectors
    Secondary expander module connectors
  5. Place the secondary expander module in a safe location, as shown in Figure 5.
    Figure 5. Secondary expander module removed from the enclosure
    Secondary expander module removed from the enclosure
  6. If needed, repeat step 2 through step 5 to remove the other secondary expander module.

Replace the secondary expansion module

  1. To reinstall the secondary expansion module, or replace it with one from FRU stock, follow the procedure in Installing or replacing a secondary expander module.