Configuring the QLogic HBA for hosts that run the Windows Server operating system
After you install the QLogic HBA and the device driver on hosts that run a Microsoft Windows Server operating system, you must configure the HBA.
About this task
For more information about supported QLogic models, see the following IBM® website:
To
configure the HBA BIOS, either use the QLogic HBA manager software
or reboot into the Fast!UTIL tool. Configure the following settings:
- Host Adapter BIOS: Disabled (unless the machine is configured for SAN Boot)
- Adapter Hard Loop ID: Disabled
- Connection Options: 1 - point to point only
- LUNs Per Target: 0
- Port Down Retry Count: 15
Set the execution throttle to a suitable queue depth for your environment, for example, a value of 100. For more information about the execution throttle and queue depth, see QLogic documentation.
If you are using Native Multipathing Plug-In (NMP), set Enable Target Reset to No. See Table 1 to include the required parameters for the registry key.
Key | Required parameters |
---|---|
HKEY_LOCAL_MACHINE > SYSTEM > CurrentControlSet > Services > ql2xxx > Parameters > Device > DriverParameters | Buschange=0;FixupInquiry=1 Note: If
you are using QLogic driver version 9.1.2.11 or later, Buschange cannot
be set to zero. See your device driver documentation for details.
|