During normal operations in a Fibre Channel environment, systems
are defined by supported configuration and zoning rules. If a single failure causes one or more of
these rules to be invalidated, the configuration is still supported until the failure is corrected
and the configuration is brought back into a normal supported mode.
Descriptions of configuration terms
A path is a logical connection between two Fibre Channel ports. The path can exist
only if both of the two Fibre Channel ports are in the same zone.
A core switch is the switch that contains the system ports. Because most SAN fabric
traffic might flow through the system, put the system in the core of the fabric. Some configurations
have a core switch that contains inter-switch links (ISLs) only and a storage edge switch that
contains the system ports. In this rules summary, a storage edge switch is the same as
a core switch.
A dual-core fabric design is an environment where two switches are both designated
as core switches in the same fabric. Every node has one Fibre Channel port that is connected to each
of the core switches. Zoning is then used to ensure that internode traffic flows only within a
single switch wherever possible.
SAN configuration rules
The system supports any SAN fabric configuration that is supported by the SAN vendors.
For more information about direct-attached configuration, see the topic about planning for a
direct-attached configuration. For specific requirements when you configure
direct attachments to the system, see the Preventive Service Planning document, Direct Attachment of Storwize® and SAN Volume Controller Systems.
Node connectivity via a SAN:
- Fibre Channel connections between the system and the switch can vary based on fibre types
and different SFPs (longwave and shortwave).
- Connections between the system and storage require the best
available bandwidth. For optimal performance and reliability, ensure that paths between the system
nodes and storage systems do not cross
ISLs. If you use ISLs on these paths, make sure that sufficient bandwidth is available. SAN
monitoring is required to identify faulty ISLs.
- Each system node must have a path to the same set of worldwide port names (WWPNs) for each storage system and must map each LUN with an identical controller LUN
number (SCSI ID) as all other ports.
- Where multiple paths exist between the system nodes and storage systems and some of those paths cross ISLs, use zoning to prevent the system from using
the paths that cross the ISLs.
- SAN routing technologies between the system and storage
systems are supported when the routing stays entirely within Fibre Channel connectivity and no other
transport technologies, such as Internet Protocol (IP), are used.
Host connectivity:
- Paths between hosts and the system can support up to three ISL hops between hosts and
system nodes.
- The system supports SAN routing technologies (including FCIP links) between the system and
hosts. However, the use of long-distance FCIP connections might degrade the performance of any
servers that are attached through this technology.
Intersystem connectivity:
- For a node port to have a usable path to a port on another node in the system, the
following conditions must be met:
- The ports must be connected to the same Fibre Channel SAN or to SANs that are
linked.
- The SAN zoning must have both the ports in at least one zone.
- The system configuration on the systems must have the port number on their system enabled
for connection to partnered systems. If the port number is not in the Fibre Channel partner
port mask, a usable path is not available.
- The system supports SAN routing technology (including FCIP links) for
intersystem connections that use Metro Mirror or Global Mirror.
General SAN configuration rules:
- To make best use of the available bandwidth between switches, use ISL trunking (also known
as port channels) on all ISLs.
- When you use Fibre Channel over IP (FCIP) or iSCSI connections, it is
best to use jumbo frames in the IP network.
- High latency links can affect performance. Regarding the length of Fibre Channel
connections in the SAN, ensure that you conform to the support statements of the SAN switch
vendors and other connected devices.
- The SAN must contain only supported switches, Fibre Channel extenders, and SAN routers. See
the following website for specific firmware levels and supported hardware:
www.ibm.com/support
Zoning rules
Notes:
- Apply these rules to each fabric that contains system ports.
- If the edge devices contain more stringent zoning requirements, follow the storage system
rules to further restrict the system zoning rules. For example, a IBM® DS4000® system does not support a
storage system A and storage system B in the same zone.
Host zoning:
- The system requires single-initiator zoning for all large
configurations that contain more than 64 host objects. Each server Fibre Channel port must be in its
own zone, which contains the Fibre Channel port and system ports. In configurations of fewer than 64
hosts, you can have up to 40 Fibre Channel ports in a host zone if the zone contains similar HBAs
and operating systems.
- For optimal performance, include a maximum of two paths per volume per host Fibre Channel
port. This ratio equates to a zone that contains one port per system node per HBA.
- For load balancing, alternate the server Fibre Channel ports between the ports of the
system. For example, the first server is zoned with ports 1 and 3 of
each system node (one system port per fabric). The second server is zoned with ports 2 and
4.
- The maximum number of supported paths to a system volume is eight.
- If a host object is not mapped to all I/O groups, do not include in the host zone system
ports from all nodes in the system. For example, if node A is in I/O group X and the host
object is mapped to I/O group X, include only ports from node A in the host zone.
The
maximum number of hosts that are mapped to an I/O group is less than the maximum number of
hosts per system. Therefore, in configurations that might grow to greater than the maximum
number of hosts per I/O group, do not map every host to every I/O group.
- When a dual-core SAN design is used, it is a requirement that no internode communications
use the ISL link. When you create host zones in this type of configuration, ensure that each
system port in the host zone is attached to the same Fibre Channel switch.
Storage system zoning:
- For most configurations, follow these rules:
- For every storage system, create one zone that contains system ports from every node and all
storage system ports, unless otherwise stated by the zoning guidelines for that storage system.
- Single-initiator zoning is not required for zones that include the system and the storage
system. The system ports are to log
in to each other to form the system.
System zoning:
- If
the system has more than one control enclosure, each node canister in the system must have at least
two ports with paths to all other nodes in the same system. The zoning requirement to meet these
rules is typically satisfied by other zones. However, for clarity for each SAN fabric, you must
create one zone that contains all ports from this system in that SAN fabric.
- If
the system has only one control enclosure and one or more Fibre Channel ports that are attached to a
SAN fabric, allow communication between node canisters over the Fibre Channel network. Creating one
zone per system in each SAN fabric and adding all ports from this system into that zone satisfies
this best practice.