Logical units and target ports on Hitachi HUS VM systems
The Hitachi HUS VM system has a maximum LUN size of 60 TB and eight Fibre Channel ports.
LUNs
A volume is referenced by the ID or the name of the LDEV.
Each Hitachi HUS VM can export 4096 LUNs to the system. The system supports greater than 2 TB LUNs.
LUN IDs
Hitachi HUS VM systems identify exported logical units through SCSI identification descriptor type 3. The 64-bit IEEE Registered Extended Identifier (NAA=5) for the logical unit is in the form 5-OUI-VSID. The HDS IEEE company ID is 00060E8. The remaining part of the company ID is a vendor-specific ID.
[11:19:00]:~ # lsmdisk 3
id 3
name mdisk2
status online
mode managed
mdisk_grp_id 2
mdisk_grp_name pool1
capacity 256.0GB
quorum_index 1
block_size 512
controller_name controller3
ctrl_type 4
ctrl_WWNN 50060E801329EB30
controller_id 0
path_count 2
max_path_count 2
ctrl_LUN_# 0000000000000003
UID 60060e801329eb00502029eb0000000400000000000000000000000000000000
preferred_WWPN
active_WWPN 50060E801329EB10
fast_write_state empty
raid_status
raid_level
redundancy
strip_size
spare_goal
spare_protection_min
balanced
tier generic_hdd
[11:19:03]:~ #
Configuring Hitachi logical drives, host groups, and paths
The system ports can be seen on the Hitachi HUS VM system.
Volumes and their corresponding logical units (LDEVs) are created, modified, or removed through the web browser. Volumes are formatted to all zeros when created.
Volumes are created as a logical device in a parity group or a dynamic provisioning (DP) pool.
Pools are created from logical devices that have no paths that are configured. For more information, see the Hitachi instructions.
Resizing or removing a LUN
LUN presentation
LUNs are exported through the available FC ports of the Hitachi HUS VM storage system. Configure these ports by host group.
Special LUNs
No special considerations are required for logical unit numbering. LUN 0 can be exported where necessary.
Target ports
A Hitachi HUS VM storage system has a total of eight Fibre Channel ports as shown in the following example.
lscontroller
id controller_name ctrl_s/n vendor_id product_id_low product_id_high
0 controller3 502029EB0001 4A HITACHI OPEN-V
1 controller2 502029EB0001 1A HITACHI OPEN-V
2 controller1 502029EB0001 2A HITACHI OPEN-V
3 controller0 502029EB0001 3A HITACHI OPEN-V
lscontroller 0
id 0
controller_name controller3
WWNN 50060E801329EB30
mdisk_link_count 15
max_mdisk_link_count 15
degraded no
vendor_id HITACHI
product_id_low OPEN-V
product_id_high
product_revision 7302
ctrl_s/n 502029EB0001 4A
allow_quorum yes (See section on Manual Quorum)
WWPN 50060E801329EB30
path_count 8
max_path_count 26
500060E8MMSSSSPP
50 - NAA format 5, Vendor responsible for address
0060E8 - ieee unique VSID of Hitachi Computer Products (America), inc.
MM - model range
SSSS - Hex for serial number
PP - Port Number
LU access model
All systems are Active/Active. To avoid an outage from system failure, cross connect the ports across Fibre Channel switches. Because all model Hitachi HUS VM storage systems are equal in priority, no benefit is received by using an exclusive set for a specific LU.
LU grouping
LU grouping does not apply to Hitachi HUS VM systems.
LU preferred access port
The model Hitachi HUS VM has no preferred access ports as all ports are Active/Active across all systems.
LUN security
LUN Security enables LUN masking by the worldwide node name (WWNN) of the initiator port. This function is used for logical units (LUs) that are used by the system.
Detecting Ownership
Detecting ownership does not apply to model Hitachi HUS VM storage arrays.