Control enclosure indicators

The front panel of the enclosure has three light-emitting diodes (LEDs) that display the overall health of the enclosure.

Figure 1 shows the enclosure health light-emitting diodes (LEDs) on the enclosure front panel.
Figure 1. Enclosure health LEDs
Enclosure health LEDs
Table 1 describes the various LED states that you might observe.
Table 1. Enclosure health LED indicators
LED Name Color States
 1 Power Green
  • OFF – No external power is supplied to the enclosure.
  • ON – Power is supplied to the enclosure and the CPU is active (not in standby) on at least one node canister.
  • SLOW FLASH – Both canisters are in standby mode.
 2  Identify Blue
  • OFF – The enclosure is not in an identify state.
  • SOLID – The enclosure was identified in response to the management system or the chassis ecosystem.
 3  Enclosure Fault Amber
  • OFF – There are no isolated FRU failures in the enclosure.
  • ON –A FRU in the enclosure has failed, and will require service or replacement.