You might need to replace a faulty thermal sensor. This sensor is used to detect the
ambient temperature of the air that is coming into the enclosure.
Before you begin
DANGER
Multiple power cords.
The product might be equipped with multiple AC power cords or multiple DC power cables. To remove
all hazardous voltages, disconnect all power cords and power cables. (L003)
About this task
To remove and replace a thermal sensor, complete the following steps:
Procedure
Refer to the system log for the location of the faulty sensor. The thermal sensors are
located in drive bays 8 and 10.
Locate the latches on the left and right front corners of the enclosure.
Lift the lower edge of each latch to release the enclosure from the rack, and then slide the
enclosure forward until the fan door is accessible.
Important: To avoid a tipping hazard, do not pull the enclosure forward any farther than
half-way.
Important: If you encounter resistance while sliding the enclosure forward, ensure that
there is adequate slack in cables in the cable management arm at the back of the enclosure.
To open the fan door, slide the two latches that are identified by blue touchpoints toward the
back of the enclosure. Then, lift the front edge of the fan door, as shown in the following
figure.
Remove the plastic fan guides next to the faulty sensor’s ribbon cable.
To disconnect the thermal sensor's ribbon cable from the enclosure midplane, pull forward
on the tabs on either side of the cable connector to release the cable from the connector. Then,
remove the sensor.
You might need to deflect the data cables above the ribbon cable
slightly to access the ribbon cable connector.
Lift the sensor from the floor of the drive bay and remove the faulty thermal sensor from
the enclosure.
Making sure that the new thermal sensor is facing upwards, insert the ribbon cable
through the drive bay and beneath the lower edge of the drive midplane.
Align the new sensor with its original location in the drive bay and press the sensor
downwards to adhere it to the chassis.
To connect the ribbon cable to the connector on the enclosure midplane, insert the cable
until it is fully seated and slide back the tabs on the connector to secure the cable.