lsbootdrive
Use the lsbootdrive command to return the drive information of the internal boot drives for the specified node.
Syntax
Parameters
- panel_name
- (Optional) Identifies the node that is being used.
Description
The command displays information about internal boot drives for the specified node (if applicable).This table provides the
possible values for attributes that are displayed as data in the output views.
| Attribute | Value |
|---|---|
| panel_id | Identifies the panel ID of the node that contains the boot drive. The value is a 7-character alphanumeric string. |
| node_id | Identifies the ID (in decimal format) of the node that contains the boot drive. |
| node_name | Identifies the name of the node that contains the boot drive. |
| can_sync | Indicates when synchronization is needed and is not prevented by
another problem. The values are yes or no. Remember: This value must be
yes when status is
out_of_sync. If the status is not out_of_sync the value
is no. |
| slot_id | Identifies the ID (in decimal format) of the slot within the node. |
| booted | Indicates whether the node started from the specified drive. The
values are yes, no. |
| status | Indicates the slot status. The values are:
|
| actual_drive_sn | Indicates the serial number of the drive in the slot. The value is an alphanumeric string or blank if no drive is in the slot. |
| configured_drive_sn | Identifies the serial number of the drive that must be in the slot. The value is an alphanumeric string or blank if no drive is in the slot. |
| actual_node_sn | Indicates the serial number of the node the drive (currently in the slot) belongs in. The value is an alphanumeric string or blank if no drive is in the slot. |
| identify | Indicates whether chnodebootdrive -identify is
specified. The following values are possible for this attribute:
|
| FRU_part_number | Identifies the field-replaceable unit (FRU) part number of the drive. The value is a 7-character alphanumeric string or blank if no drive exists. |
| FRU_identity | Identifies the 11S number that combines the manufacturing part number and serial number. The value is a 22-character alphanumeric string. |
Note: If
the status is
out_of_sync and can_sync is set to
no, look for an indication to determine what must be fixed to make
resynchronization possible.