Table 1 describes the various LED states that you might observe.
Table 1. Canister and node status LED descriptions
LED Name
Icon
Color
States
1 Canister power
Green
OFF – No external power is supplied to the canister.
ON – The canister is in a power-on state.
SLOW FLASH – The canister is in standby mode.
FAST FLASH – The BIOS is in POST.
2 Battery status
Green
OFF – The battery has a fault or is otherwise not available for use.
ON – The battery is fully charged and can support two fire hose dumps (FHDs).
FLASH – The battery is charging but it can support a single fire hose dump. (FHD).
FAST FLASH – The battery is charging but has insufficient charge to complete a single fire
hose dump. (FHD).
3 Node status
Green
OFF – The canister is in standby mode (the CPU is off , POST is running, or the operating
system is loading), or power is not supplied to the canister.
ON – The node is in active state (part of a cluster).
FLASH – The node is in candidate or service state. It is safe to remove the node.
FAST FLASH – A destage is occurring.
4 Activity
Green
Not used
5 Canister fault
Amber
OFF – There are no isolated FRU failures in the canister.
ON –An FRU in the canister has failed, and requires service or replacement.
FLASHING – The node is being identified.
Node port indicators
Each Node canister
Ethernet port has a pair of green LEDs with the following meanings.Figure 2. SFP port LEDs
1 SFP port LEDs
Figure 3. Management port LEDs and technician port LEDs