You can remove the expansion canisters in a 5U expansion enclosure.
Before you begin
Important: You can remove an expansion canister without powering off the expansion
enclosure. However, to maintain operating temperature, perform the following tasks.
Do not remove a faulty expansion canister until its replacement is ready to be installed.
Do not remove an expansion canister from an operational enclosure for more than approximately 10
minutes. The reduction in airflow through the enclosure might cause the enclosure or its components
to shut down to protect from overheating.
About this task
An expansion canister provides SAS connectivity between the 5U expansion enclosure and control
enclosure system. If either of the two expansion canisters has a failure, the other expansion
canister assumes the full I/O load. Figure 1 shows the features of an expansion enclosure.
Figure 1. Expansion canister
1 Canister fault indicator
2 Canister status
3 Canister power indicator
4 and 6 SAS link fault indicators
5 and 7 SAS link operational
indicators
8 Canister release handles
Procedure
Read all safety information.
Locate the expansion canister to be removed.
Release the lower cable management arm to swing it out of the way, as described in Figure 1.