565 The internal drive of the node is failing.
Explanation
The internal drive within the node is reporting too many errors. It is no longer safe to rely on the integrity of the drive. Replace the drive.
User response
For IBM® SAN Volume Controller, follow
troubleshooting procedures to fix the hardware:
- View hardware information.
- Replace parts (canister or disk).
For IBM Storage Virtualize for Public Cloud and IBM Storage Virtualize, contact your hardware manufacturer.
For FlashSystem 7200 and FlashSystem 9200, follow
troubleshooting procedures to fix the hardware:
- The drive of the node canister cannot be replaced individually. Follow the hardware remove and replace instructions to change the node canister.
Possible Cause—FRUs or other:
- For FlashSystem 7200 and FlashSystem 9200, node canister (100%)