CMMVC1554E The command failed because grid orchestration is pending for one or more member systems.
Explanation
One or more member systems of the FlashSystem grid are yet to receive the latest grid configuration. The time required to receive the latest grid configuration depends on current levels of system activity. A coordinator change operation can take a few seconds to several minutes for completion depending on current levels of system activity. A network issue or an existing error event or error code against the FlashSystem grid configuration can cause a delay in receiving the latest grid configuration.User response
- Check whether any error event or error code is raised for the system on the FlashSystem grid dashboard of the current coordinator or any network issue has occurred.
- Or, if the current FlashSystem grid configuration
operation is pending, wait until the configuration completes and try again. You can track progress
of the configuration operation by verifying that the generation number of each member system is at
the same level. The generation number is displayed next to each member system
in
the output of the lsgridsystem
command.Note: The generation number indicates the latest FlashSystem grid information for each member system. A higher generation number value indicates more recent information.