lsnodepsu

Use the lsnodepsu command to display the power supply unit information of nodes in a system.

Syntax

Read syntax diagramSkip visual syntax diagram lsnodepsu -psuPSU_idnode_id_or_name

Parameters

-delim delimiter
(Optional) Specify a delimiter to separate data in the output.
-nohdr
(Optional) Suppress the headings in the output.
-filtervalue attribute=value
(Optional) Specifies a list of one or more filters. Only objects with a value that matches the filter attribute value are displayed.
-filtervalue?
(Optional) Displays a list of valid filter attributes.
-psu PSU_id
(Optional) Specifies the ID of the PSU. You must specify a node_id or node_name if you use the -psu parameter.
node_id | node_name
(Optional) Specifies the node ID or node name (as listed in the lsnode command).

Description

This table provides the possible values that are applicable to the attributes that are displayed as data in the output views.
Table 1. Attribute values for lsnodepsu
Attribute Value
node_id Indicates the ID, as shown in lsnode, of the node in which the PSU is located.
node_name Indicates the name, as shown in lsnode, of the node in which the PSU is located.
PSU_id Indicates the ID of the PSU.
status Indicates the overall status of the PSU. The possible values are:
  • offline
  • online
  • degraded
  • unknown
input_failed Indicates the state of the input failed LED on the PSU. The value is either on or off.
output_failed Indicates the state of the output failed LED on the PSU. The value is either on or off.
fan_failed Indicates the state of the fan failed LED on the PSU. The value is either on or off.
swapped Indicates whether the PSU has been swapped since power-on or the last clear swap. The value is either yes or no.
redundant Indicates whether the PSU is redundant. The value is either yes or no.
FRU_part_number Indicates FRU part number of the PSU. The value is an ASCII string up to 22 characters.
FRU_identity Indicates FRU identity of the PSU. The value is an ASCII string up to 22 characters.
firmware_level_1 Indicates the firmware level of the PSU. The value is an ASCII string up to 22 characters.