507 No enclosure identity and no node state
Explanation
The node canister has been placed in a replacement enclosure midplane. The node canister is also a replacement or has had all cluster state removed from it.
User response
Follow troubleshooting procedures to relocate
the nodes to the correct location.
- Check the status of the other node in the enclosure. Unless it also shows error 507, check the errors on the other node and follow the corresponding procedures to resolve the errors. It typically shows node error 506.
- If the other node in the enclosure is also reporting 507, the enclosure and both node canisters have no state information. Contact IBM support. They will assist you in setting the enclosure vital product data and running cluster recovery.
Possible Cause-FRUs or other:
- None