1625 Incorrect disk controller configuration.
Explanation
While running an MDisk discovery, the cluster has detected that a disk controller's configuration is not supported by the cluster. The disk controller might appear to be operating with the cluster; however, the configuration detected can potentially cause issues and should not be used. The unsupported configuration is shown in the event data.
User response
- Use the event data to determine changes required on the disk controller and reconfigure the disk controller to use a supported configuration.
- Mark the error that you have just repaired as
fixed
. If the problem has not been fixed it will be logged again by the managed disk discovery that automatically runs at this time; this could take a few minutes. - Run the fix procedure from the event log menu in the GUI.
Possible Cause-FRUs or other:
- None
Other:
- Enclosure/controller fault