1267 Enclosure secondary expander module is missing
Explanation
An error occurred involving a secondary expander module (SEM). You might be able to resolve the problem by reseating the SEM. The alert event gives more information about the error.
- 045105 Enclosure secondary expander module has failed
- A SEM is offline and might have failed.
- 045107 Enclosure secondary expander module temperature sensor cannot be read
- A SEM temperature sensor could not be read.
- 045114 Enclosure secondary expander module connector excluded due to too many change events
- A SEM is in degraded state due to too many transient errors.
- 045120 Enclosure secondary expander module is missing
- A SEM was removed from the disk drawer for an enclosure.
- 045121 Enclosure secondary expander module connector excluded due to dropped frames
- An internal SAS connector in the enclosure is in a degraded state due to too many Virtual LUN Manager login errors.
- 045122 Enclosure secondary expander module connector is excluded and cannot be unexcluded
- An internal SAS connector in the enclosure was excluded and cannot be included.
- 045123 Enclosure secondary expander module connectors excluded as the cause of single ported drives
- SEM connectors were excluded because slot ports under them were unreachable.
- 045124 Enclosure secondary expander module leaf expander connector excluded as the cause of single ported drives
- An SEM leaf expander connector was excluded because slot ports under it were unreachable.
User response
Complete the following steps:
- Reseat the SEM:
- Enable maintenance mode for the I/O group.
- Slide the enclosure out of the rack sufficiently to open the access lid.
- Remove the designated SEM.
- Reinsert the designated SEM.
- Maintenance mode will disable automatically after 30 minutes, or you can disable it manually.
- If the error autofixes, close up the enclosure:
- Close the access lid.
- Slide the enclosure back into the rack.
- If the error does not autofix, replace the SEM:
- Enable maintenance mode for the I/O group.
- Slide the enclosure out of the rack sufficiently to open the access lid.
- Remove the failed SEM.
- Insert the replacement SEM.
- Close the access lid.
- Slide the enclosure back into the rack.
- Maintenance mode will disable automatically after 30 minutes, or you can disable it manually.