1179 Too many drives attached to the system.

Explanation

The cluster supports only a fixed number of drives. A drive was added that makes the number of drives larger than the total number of supported drives per cluster.

User response

  1. Disconnect any excessive unmanaged enclosures from the system.
  2. Unmanage any offline drives that are not present in the system.
  3. Identify unused drives and remove them from the enclosures.
  4. Identify arrays of drives that are no longer required.
  5. Remove the arrays and remove the drives from the enclosures if they are present.
  6. After there are fewer than the maximum supported number of drives in the system, consider reengineering system capacity by migrating data from small arrays onto large arrays, then removing the small arrays and the drives that formed them. Consider the need for another Storwize system in your SAN solution.