1155 A power domain error has occurred.
Explanation
Both 2145s of a pair are powered by the same uninterruptible power supply.
User response
- List the 2145s of the cluster and check that 2145s in the same I/O group are connected to a different uninterruptible power supply.
- Connect one of the 2145s as identified in step 1 to a different uninterruptible power supply.
- Mark the error that you have just repaired,
fixed
. - Run the fix procedure from the event log menu in the GUI.
Possible Cause-FRUs or other:
- None
Other:
- Configuration error