1040 Node flash disk fault
Explanation
A flash module error occurred after a successful system start. Note: The node that contains the flash module was not rejected by the cluster.
User response
- Replace the FRUs.
- Check node status. If all nodes show a status of Online, mark the error that you just repaired
as
fixed
. If any nodes do not show a status of Online, start the fix procedure. If you return to this step, contact support to resolve the problem. - Run the fix procedure from the event log menu in the GUI.