Error event IDs and error codes

Error codes describe a service procedure that must be followed. Each event ID that requires a service has an associated error code.

Error codes can be either notification type E (error) or notification type W (warning). Table 1. Error event IDs and error codes lists the event IDs that have corresponding error codes, and shows the error code, the notification type, and the condition for each event. For a list of informational events, which have no associated error codes, see Informational events.

The 07nnnn event ID range refers to node errors that were logged by the system. The last 3 digits represent the error that was reported by the node. You can find these codes in the error code reference.

Table 1. Error event IDs and error codes
Event ID Notification type Condition Error code
000843 W Patches on this node do not match the patches on the system. 2015
009012 W DNS server failure. The DNS server cannot be reached over the network by the cluster. 1585
009020 E A system recovery has run. All configuration commands are blocked. 1001
009040 E The error event log is full. 1002
009052 W The following causes are possible:
  • The node is missing.
  • The node is no longer a functional member of the system.
1196
009053 E A node has been missing for 30 minutes. 1195
009054 W The node has been shut down. 1707
009100 W The software install process has failed. 2010
009101 W Software installation package cannot be delivered to all nodes. 2010
092000 W IBM VASA provider service failed to start. 4402
009110   The software installation process stalled due to lack of redundancy. 2010
009115   The software downgrade process stalled due to lack of redundancy. 2008
009150 W Unable to connect to the SMTP (email) server. 2600
009151 W Unable to send mail through the SMTP (email) server. 2601
009153 W The system did not send an email. 2601
009170 W Remote Copy feature capacity is not set. 3030
009171 W The FlashCopy® feature capacity is not set. 3031
009172 W The Virtualization feature has exceeded the amount that is licensed. 3032
009173 W The FlashCopy feature has exceeded the amount that is licensed. 3032
009174 W Remote Copy feature license limit exceeded. 3032
009175 W Thin-provisioned volume usage is not licensed. 3033
009176 W The value set for the virtualization feature capacity is not valid. 3029
009177 E A physical disk FlashCopy feature license is required. 3035
009178 E A physical disk Metro Mirror and Global Mirror feature license is required. 3036
009179 E A virtualization feature license is required. 3025
009180 E Automatic recovery of offline node failed. 1194
009181 W Unable to send email to any of the configured email servers. 3081
009182 W The external virtualization feature license limit was exceeded. 3032
009183 W Unable to connect to LDAP server. 2251
009184 W The LDAP configuration is not valid. 2250
009185 E The limit for the compression feature license was exceeded. 3032
009186 E The limit for the compression feature license was exceeded. 3032
009187 E Unable to connect to an LDAP server that has been automatically configured. 2256
009188 E Invalid LDAP configuration for automatically configured server. 2255
009189 W A licensable feature's trial-timer has reached 0. The feature has now been deactivated. 3082
009190 W A trial of a licensable feature expires in 5 days. 3083
009191 W A trial of a licensable feature expires in 10 days. 3084
009192 W A trial of a licensable feature expires in 15 days. 3085
009193 W A trial of a licensable feature expires in 45 days. 3086
009194 W Easy Tier® feature license limit exceeded. 3032
009195 W FlashCopy feature license limit exceeded. 3032
009196 W External virtualization feature license limit exceeded. 3032
009197 W Remote copy feature license limit exceeded. 3032
009198 W System update completion is required. 2050
009199 W System update completion has stalled. 2012
009200 W Encryption feature license limit exceeded. 3032
009201 W The quorum application is out of date and must be redeployed. 3123
009202 W System SSL certificate will expire within the next 30 days. 3130
009203 W System SSL certificate has expired. 2258
009205 W No active quorum device found on this cluster. 3124
009207 W The quorum application is not storing system data correctly. 3127
009208 W Local user passwords must be changed. 3310
009209 W The LDAP administrator password must be changed. 3320
009210 W The superuser password must be changed. 3330
009216 W Object available threshold has been reached. 3040
009217 W Role elevation requests are approved. 3375
009218 W The two person integrity state is inconsistent because the superuser was unlocked while two person integrity is enabled. 3380
009219 W Role elevation requests are pending for approval. 3375
009220 W The metadata migration task failed. Contact IBM® Support to resolve the issue. 4200
009221 W SNMP authentication and privacy passphrases must be changed. 3335
009222 W Truststore slots tagged 'vasa' could not be migrated to the metadata vdisk 4250
010002 E The node ran out of base event sources. As a result, the node has stopped and exited the system. 2030
010003 W The number of device logins has reduced. 1630
010004 W Device excluded due to excessive errors on all Managed Disks. 1640
010006 E Access beyond end of disk, or Managed Disk missing. 2030
010008 E The block size is invalid, the capacity or LUN identity has changed during the managed disk initialization. 1660
010010 E The managed disk is excluded because of excessive errors. 1310
010011 E The remote port is excluded for a managed disk and node. 1220
010012 E The local port is excluded. 1210
010013 E The login is excluded. 1230
010015 E Timeout due to non-responsive device. 1340
010016 E Timeout due to lost command 1340
010017 E A timeout has occurred as a result of excessive processing time. 1340
010018 E An error recovery procedure has occurred. 1370
010019 E A managed disk is reporting excessive errors. 1310
010020 E The managed disk error count threshold has exceeded. 1310
010021 W There are too many devices presented to the system. 1200
010022 W There are too many managed disks presented to the system. 1200
010023 W There are too many LUNs presented to a node. 1200
010024 W There are too many drives presented to a system. 1200
010025 W A disk I/O medium error has occurred. 1320
010026 W A suitable MDisk or drive for use as a quorum disk was not found. 1330
010027 W The quorum disk is not available. 1335
010028 W A controller configuration is not supported. 1625
010029 E A login transport fault has occurred. 1360
010030 E A managed disk error recovery procedure (ERP) has occurred. The node or controller reported the following:
  • Sense
  • Key
  • Code
  • Qualifier
1370
010031 E One or more MDisks on a controller are degraded. 1623
010032 W The controller configuration limits failover. 1625
010033 E The controller configuration uses the RDAC mode; this is not supported. 1624
010034 W Persistent unsupported controller configuration. 1695
010035 W Controller has quorum disabled, but quorum disk is configured. 1570
010040 E The controller system device is only connected to the node through a single initiator port. 1627
010041 E The controller system device is only connected to the node through a single target port. 1627
010042 E The controller system device is only connected to the nodes through a single target port. 1627
010043 E The controller system device is only connected to the nodes through half of the expected target ports. 1627
010044 E The controller system device has disconnected all target ports to the nodes. 1627
010045 W The number of Device paths from the controller site allowed accessible nodes has reduced 1630
010050 W Solid state drive failed and rebuild is required. 1201
010051   A Solid state drive is missing from the configuration 1202
010052 E Solid state drive offline as a result of a drive hardware error. 1205
010053 E Solid state drive reporting PFA errors. 1215
010054 E Solid state drive reporting too many errors. 1215
010055 W An unrecognized SAS device. 1665
010056 E SAS error counts exceeded the warning thresholds. 1216
010057 E SAS errors exceeded critical thresholds. 1216
010058 E The drive initialization failed because of an unknown block size or a block size that is not valid; an unknown capacity or a capacity that is not valid; or was not able to set the required mode pages. 1661
010059 E Solid state drive offline due to excessive errors. 1311
010060 E Solid state drive exceeded warning temperature threshold. 1217
010062 E A drive exceeded the warning temperature threshold. 1217
010063 W Drive medium error. 1321
010064 E Timeout due to TTO IMMEDIATE. 1340
010066 W Controller indicates that it does not support descriptor sense for LUNs that are greater than 2 TBs. 1625
010067 W Too many enclosures were presented to a system. 1200
010068 E Format of the solid state drive is corrupted. 1204
010069 E Solid state drive has incorrect block size. 1204
010070 W Too many controller target ports were presented to the system. 1200
010071 W Too many target ports were presented to the system from a single controller. 1200
010072 E The drive is offline as a result of a drive hardware error. 1680
010073 E The drive is reporting predictive failure analysis (PFA) errors. 1680
010080 E The drive is reporting too many errors. 1680
010081 E The drive format is corrupted. 1206
010082 E The block size for the drive was incorrect. 1206
010083 E The drive is offline due to excessive errors. 1680
010084 E The error counts for the SAS drive exceeded the warning thresholds. 1285
010085 W The SAS device was not recognized. 1666
010086 W The SAS enclosure was not recognized. 1666
010087 W The SAS device was not able to be identified. 1666
010088 E There were excessive medium errors on the drive. 1680
010089 E There were excessive overall timeout errors on the drive. 1680
010090 E There were excessive times when the drive stopped. 1680
010091 E A drive failed validation testing. 1680
010092 E Excessive medium errors on the solid state drive. 1215
010093 E Excessive overall timeout errors on the solid state drive. 1204
010094 E Login excluded. 1230 or 1231
010095 E Drive failed. 1687
010096 E The drive initialization failed because of an unknown block size or a block size that is not valid; an unknown capacity or a capacity that is not valid; or was not able to set the required mode pages. 1680
010097 E A drive is reporting excessive errors. 1685
010098 W There are too many drives presented to a system. 1200
010100 W Incorrect connection to a port was detected. 1669
010101 E Too many long I/O operations to drive. 1680
010102 E A drive is reported as continuously slow with contributing factors. 1680
010103 E Too many long I/O operations to drive (Mercury drives). 1680
010104 E A drive is reported as continuously slow because of multiple factors (Mercury drives). 1680
010105 W Storage system connected to unsupported port. 2080
010106 E Drive reporting too many t10dif errors. 1680
010107 W Encrypting MDisk is no longer encrypted. 2580
010110 W Drive firmware download canceled because of system changes. 3090
010111 W Drive firmware download canceled because of a drive download problem. 3090
010117 W A disk controller is not accessible from a node allowed to access the device by site policy. 1627
010118 W Too many drives attached to the system. 1179
010119 W Drive data integrity error. 1322
010120 W A member drive has been forced to turn off protection information support. 2035
010121 E Drive exchange required. 1693
010123 W Performance of external MDisk has changed. 2115
010124 W iSCSI session excluded. 1230
010125 W A flash drive is expected to fail because its write endurance value exceeds 95. 1215
010126 W The usage rate for a flash drive is high, which can affect the expected lifespan of the drive. 2560
010128 W Drive erase operation is corrupted. 3340
020001 E There are too many medium errors on the MDisk. 1610
020002 E A storage pool is offline. 1620
020003 W There are insufficient virtual extents. 2030
020008 E Storage optimization services disabled. 3023
020009 E Compressed array running low on physical space. 1246
020010 E Critical level of compressed array running low on physical space. 1246
020011 E 1% physical space left for compressed array. 1242
020012 E Compressed array out of physical space. 1241
020013 W EasyTier is set to active mode in pool with unsupported configuration, this may result in reduced performance. 1846
020014 W EasyTier is set to measure mode due to unsupported configuration in pool. 1845
020015 W Easy Tier cannot optimize data placement because there is not enough available capacity in the pool. 1878
020017 W Easy Tier protection limit exceeded on an overprovisioned managed disk. 1915
029001 E The MDisk has bad blocks. 1840
029002 W The system failed to create a bad block because MDisk already has the maximum number of allowed bad blocks. 1226
029003 W The system failed to create a bad block because the system already has the maximum number of allowed bad blocks. 1225
030000 W FlashCopy prepare failed due to cache flush failure. 1900
030010 W FlashCopy has been stopped due to the error indicated in the data. 1910
030015 W The Volume Group Snapshot is degraded. 1911
030016 W The Clone or Thin-Clone Volume is corrupt. 1912
030020 W Unrecovered FlashCopy mappings. 1895
030021 W Automated snapshot not collected at expected time. 1913
030022 W Automated cloud backup not initiated at expected time. 1914
030023 W Ongoing cloud backup is not yet completed, the next scheduled backup might fail to trigger at scheduled time.  
030024 W Failed to remove automated cloud backup generation.  
030025 W The cloud backup missed the scheduled time.  
045001 E One or more power supply unit fans have failed. 1124
045002 E A fan is operating outside the expected range. 1126
045003 E There was a fan status communications failure. 1126
045004 W The power supply unit is not installed. 1128
045005 W The power supply unit has indicated an input power failure. 1138
045006 E The power supply unit has indicated an output failure. 1126
045007 E The power supply unit has failed. 1124
045008 E Cannot communicate with the power supply unit. 1148
045009 E The PSU type is not valid for this enclosure type. 1124
045010 E The power supply unit type is unknown to this product. 1124
045011 E PSU 11S serial number not valid. 1124
045012 W The canister temperature is at the warning level. 1098
045013 W The canister temperature is at the critical level. 1095
045014 E A SAS cable was excluded due to internal errors. 1260
045015 E A SAS cable was excluded because too many change events were caused. 1260
045016 E A SAS cable was excluded. 1255
045017 E A SAS cable is operating at a reduced speed. 1260
045018 E A SAS cable was excluded because frames were dropped. 1260
045019 E A SAS cable was excluded because the enclosure discovery timed out. 1260
045020 W A SAS cable is not present. 1265
045021 W A canister was removed from the system. 1036
045022 E A canister has been in a degraded state for too long and cannot be recovered. 1034
045023 E A canister is encountering communication problems. 1038
045024 E The canister VPD is not valid. 1032
045025 E The canister has experienced too many resets. 1032
045026 E The drive slot is causing the network to be unstable. 1686
045027 E The drive slot is not running at 6 Gbps. 1686
045028 E The drive slot is dropping frames. 1686
045029 E The drive is visible through only one SAS port. 1686
045031 E The drive power control is not functional. 1008
045032 E A drive is present in the slot but does not respond to any SCSI or SAS commands. 1686
045033 E The drive slot contains a device that is not responding to queries. 1685
045034 E The managed enclosure is not visible from any node canisters. 1042
045035 E The electronics in the enclosure has failed. 1694
045036 E The electronics in the enclosure has experienced a critical failure. 1008
045037 E The SAS network has too many errors. 1048
045038 E The SAS network has too many errors. 1048
045040 W The firmware update for the enclosure component has failed. 3015
045041 W More than one initiator port was detected on the same strand. 1005
045042 W The order of the enclosures is different on each strand. 1005
045044 W Multiple canisters are connected to a single canister port. 1005
045045 W Canister one is connected to canister two. 1005
045046 W An enclosure is connected to more than one I/O group. 1005
045047 W A managed enclosure is connected to the wrong I/O group. 1005
045048 W An enclosure is connected to more than one chain. 1005
045049 W Too many canisters are connected to a strand. 1005
045050 W The canister is connected to the wrong port. 1005
045051 E A SAS cable is excluded because of single port active drives. 1260
045052 W More than one canister was detected at the same hop count. 1005
045053 E The node location is not able to be detected. 1031
045054 E An enclosure display cannot be updated. 1694
045055 E There is an enclosure battery fault. 1118
045056 E An enclosure battery is missing. 1112
045057 E An enclosure battery is nearing end of life. 1114
045058 E An enclosure battery is at end of life. 1113
045060 E Drive slot cannot be excluded. 1048
045062 W An enclosure battery conditioning is required but not possible. 1131
045063 E There was an enclosure battery communications error. 1116
045064 W A SAS port is active, but no enclosures can be detected. 1005
045065 E There is a connectivity problem between a canister and an enclosure. 1036
045066 E The FRU identity of the enclosure is not valid. 1008
045067 W A new enclosure FRU was detected and needs to be configured. 1041
045068 E The internal device on a node canister was excluded because of too many change events. 1034
045069 E The internal connector on the node canister was excluded as the cause of single ported drives. 1034
045070 W The canister temperature sensor cannot be read. 1034
045071 W The enclosure contains both a node canister and an expansion canister. 1037
045072 E The discovery failed to complete. 1048
045073 E The VPD for the enclosure cannot be read. 1048
045074 W The PSU temperature is at the warning level. 1098
045075 W The PSU temperature is at the critical level. 1095
045076 E Error reading PSU temperature sensor. 1124
045077 E Attempts to exclude connector have failed. 1260
045080 E There are too many self-initiated resets on the enclosure. 1048
045081 E The PSU has attempted too many internal recovery actions. 1124
045082 E The slots are powered off. 1048
045083 W The enclosure configuration is not supported. 1005
045084 W There are too many SDE enclosures on strand. 1005
045085 W The SDE is detected in a chassis that is not valid. 1005
045086 E Node canister internal connector failed because of dropped frames. 1034
045102 W SAS cable is not working at full capacity. 1260
045103 E An attempt to automatically configure a reseated or replaced drive has failed. 1686
045104 W Drives are single ported due to a spare node. 3200
045105 E Enclosure secondary expander module has failed. 1267
045106 E Enclosure secondary expander module FRU identity is not valid. 1266
045107 E Enclosure secondary expander module temperature sensor cannot be read. 1267
045108 E Enclosure secondary expander module temperature has passed warning threshold. 1098
045109 E Enclosure secondary expander module temperature has passed critical threshold. 1095
045110 E Enclosure display panel is not installed. 1268
045111 E Enclosure display panel temperature sensor cannot be read. 1268
045112 E Enclosure display panel temperature has passed warning threshold. 1098
045113 E Enclosure display panel temperature has passed critical threshold. 1095
045114 E Enclosure secondary expander module connector excluded due to too many change events. 1267
045119 E Enclosure display panel VPD cannot be read. 1268
045120 E Enclosure secondary expander module is missing. 1267
045121 E Enclosure secondary expander module connector excluded due to dropped frames. 1267
045122 E Enclosure secondary expander module connector is excluded and cannot be unexcluded. 1267
045123 E Enclosure secondary expander module connectors excluded as the cause of single ported drives. 1267
045124 E Enclosure secondary expander module leaf expander connector excluded as the cause of single ported drives. 1267
045137 E Cannot communicate with the PSU. 1123
045138 W PSU is not installed correctly. 1127
045139 E Drive slot contains a device that is not responding. 1686
045140 W Power supply unit has an invalid input voltage. 1297
045141 W Power supply units are mismatched. 1298
045142 W There are too many transient temperature events in the past 24 hours. 1098
045143 E Canister has failed due to a secure boot failure. 1063
045145 E Canister has a secure boot failure caused by the BIOS. 1073
050001 W The Metro Mirror or Global Mirror relationship cannot be recovered. 1700
050002 W A Metro Mirror or Global Mirror relationship or consistency group exists within a system, but its partnership is deleted. 3080
050010 W A Global Mirror relationship has stopped because of a persistent I/O error. 1920
050011 W A remote copy has stopped because of a persistent I/O error. 1915
050020 W Remote Copy relationship or consistency groups lost synchronization. 1720
050030 W There are too many system partnerships. The number of partnerships has been reduced. 1710
050031 W There are too many system partnerships. The system has been excluded. 1710
050040 W Background copy process for the remote copy was blocked. 1960
050041 W Partner cluster IP address unreachable. 2021
050042 W Cannot authenticate with partner cluster. 2022
050043 W Unexpected cluster ID for partner cluster 2023
050050 E The Global Mirror secondary volume is offline. The relationship has pinned hardened write data for this volume. 1925
050060 E The Global Mirror secondary volume is offline due to missing I/O group partner node. The relationship has pinned hardened write data for this volume but the node containing the required data is currently offline. 1730
050070 E Global Mirror performance is likely to be impacted. A large amount of pinned data for the offline volumes has reduced the resource available to the global mirror secondary disks. 1925
050080 W HyperSwap® volume has lost synchronization between sites. 1940
050081 W HyperSwap consistency group has lost synchronization between sites. 1940
050082 E Compression has stopped unexpectedly. 3131
050090 W The system cannot compress data being sent to the remote system in an IP partnership due to local system limitations. 3131
050091 W The system cannot compress data being sent to the remote system in an IP partnership due to remote system limitations. 3145
050092 W The system has stopped compressing data that is being sent to a remote system in an IP partnership due to bandwidth limits. 3150
051000 W Local command failure during replicated volumegroup configuration. 4020
051002 W Remote command failure during replicated volumegroup configuration. 4100
051003 E Undiagnosed loss of management network connectivity during replication configuration. 4030
051004 W Loss of management communication during replication configuration. 4110
051005 W Replication configuration is blocked by an upgrade on the remote system. 4110
051006 W Missing pool link when creating a replicated volume. 4100
051007 W Loss of management network connectivity due to a REST HTTP error during replication configuration. 4110
051008 W Loss of management network connectivity due to a REST URL error during replication configuration. 4110
051009 W A local command failed during replicated storage partition configuration. 4020
051011 W A volume in a storage partition can't be created because its pool isn't linked. 4100
051012 W The replicated storage partition cannot be created because its replication policy is being deleted. 4100
051013 W The replicated storage partition has been removed from the remote system. 4100
051014 W A volume group cannot be created because its ownership group isn't linked. 4100
051016 W Storage partitions linked for disaster recovery are both configured for high availability. 4410
051017 W Partnership status is not fully configured. 4268
051018 W Partner Cluster IP address unreachable or not present. 4268
051019 W Unable to setup FC partnership on source system. 4270
051020 W Unable to change the preferred management location. 4020
051022 W Unable to unassign the replication policy from the storage partition. 4020
051023 W Unable to communicate to remote system due to REST failure. 4280
051024 W Remote system does not support storage partition migration. 4268
051025 W Desired partner system not found. 4268
051026 W HA replication policy can not be configured with existing async DR. 4020
051027 W Unable to setup FC partnership on the desired target system. 4280
051028 W Unable to setup replication policy on source system. 4270
051029 W Unable to setup replication policy on desired target system. 4280
051030 W Existing replication policy is conflicting with requested storage partition migration. 4268
051031 W Unable to assign replication policy to the storage partition. 4270
051033 W The storage partition migration cannot proceed as the source and target systems are members of different Flash Grids. 4268
051034 W Storage partition merge failed. 4020
051035 W The storage partition migration cannot proceed as the desired target system has a lower code level than the source system. 4268
051037 W The remote DR linked partition is no longer linked to this partition. 4411
051038 W The remote DR linked partition is missing. 4412
051043 W A host in a highly available storage partition cannot be created because its portset is not linked on the remote system. 4100
051044 W A host in a highly available storage partition can not be created because its portset is linked to a mismatched portset type on the remote system. 4100
051045 W A host in a highly available storage partition cannot be created because the remote portset is empty. 4100
051421 W User initiated storage partition migration rollback to the source system. 4260
051422 W Storage partition migration paused as all the nodes are not online on the desired system. 4268
051015 W Host validation required to proceed with partition migration. 4260
051021 W

Source copy deletion is pending, verify multipath configurations and IO performance before committing to the migration.

4260
051032 W Host does not have sufficient logins on desired target system to continue with storage partition migration. 4268
052000 W Replication stopped due to a medium error during synchronization. 4050
052001 E Replication stopped due to a read error during synchronization. 4058
052002 W Replication suspended and a full resynchronization is required for one or more volume groups. 4040
052003 W Unrecovered volume group replication metadata. 4010
052005 W A partnership used for high availability has reduced protection as it does not have an active quorum application. 3129
052006 W A quorum application used for high availability between systems is not connected to all nodes in both systems. 3129
052007 W High availability of a storage partition has been lost. 4220
052008 E A storage partition is unable to re-establish high availability. Contact support. 4240
052010 W High availability of the storage partition is suspended as it contains recovery volume groups. 4221
060001 W A thin-provisioned volume copy is offline because of insufficient space. 1865
060002 E A thin-provisioned volume copy is offline because of corrupt metadata. 1862
060003 E A thin-provisioned volume copy is offline because of a failed repair. 1860
060004 W A compressed volume copy is offline because of insufficient space. 1865
060005 E A compressed volume copy is offline because of corrupt metadata. 1862
060006 E A compressed volume copy is offline because of a failed repair. 1860
060007 E A compressed volume copy has bad blocks. 1850
060008 W Data reduction pool meta data corrupt. 1862
060009 W The virtual disk copies for a pool are offline because the data reduction pool was not repaired. 1860
060010 W The virtual disk copies for a pool are offline because of insufficient space on the data reduction pool. 1865
060012 W Data reduction pool space warning. 1867
062001 W The system is unable to mirror medium error. 1950
062002 E A mirrored volume is offline because it cannot synchronize data. 1870
062003 W Repair of a mirrored volume stopped because of the difference. 1600
064001 W A host port has more than four logins to a node. 2016
064002 W Host and Fibre Channel port must be in the same portset. 3454
064003 W One or more configured hosts are offline. 2017
064004 W One or more FC-NVMe hosts are mapped to the default FC portset instead of user-defined FC portset. 3455
070000 E Unrecognized node error. 1083
070510 E Detected memory size does not match the expected memory size. 1022
070511 E DIMMs are incorrectly installed. 1009
070513 E Uncorrectable memory error was detected. 1022
070517 E The WWNN that is stored on the service controller and the WWNN that is stored on the drive do not match. 1192
070521 E Unable to detect any Fibre Channel adapter. 1016
070522 E The system board processor has failed. 1020
070523 E The internal disk file system of the node is damaged. 1187
070524 E Unable to update BIOS settings. 1027
070525 E Unable to update the service processor firmware for the system board. 1020
070528 E The ambient temperature is too high while the system is starting. 1182
070534 E System board fault. 1026
070536 E A system board device breached a critical temperature threshold. 1084
070538 E A PCI Riser breached a critical temperature threshold. 1085
070541 E Multiple hardware failures. 1184
070542 E The processor failed. 1024
070543 E No usable persistent data was found on the boot drives. 1035
070544 E The boot drives do not belong in this node. 1035
070545 E Boot drive and system board do not match. 1035
070547 E Pluggable TPM is missing or broken. 1051
070548 E The node has compression hardware configured but no compression hardware is available. 1046
070549 E The node's compression hardware failed. 1046
070550 W Cannot form system due to lack of resources. 1192
070551 W Cannot form cluster due to lack of cluster resources, overridequorum possible. 1192
070556 E Duplicate WWNN detected on the SAN. 1192
070558 E A node is unable to communicate with other nodes. 1192
070562 E The node hardware does not meet minimum requirements. 1183
070564 E Too many software failures. 1188
070568 E Unable to upgrade adapter firmware. 1469
070572 E Battery protection temporarily unavailable; both batteries are expected to be available soon. 1473
070573 E Node software inconsistent. 1192
070574 E The node software is damaged. 1187
070576 E The system data cannot be read. 1030
070578 E The system data was not saved when power was lost. 1194
070580 E Unable to read the service controller ID. 1192
070690 W Node held in service state. 1189
070700 W Fibre Channel adapter missing. 1045
070701 E Fibre Channel adapter failed. 1046
070702 E Fibre Channel adapter PCI error. 1046
070703 E Fibre Channel adapter degraded. 1046
070704 W Fewer Fibre Channel ports operational. 1060
070705 W Fewer Fibre Channel I/O ports operational. 1450
070706 W Fibre Channel clustered system path failure. 1550
070711 E SAS adapter failed. 1046
070712 E SAS adapter PCI error. 1046
070713 E SAS adapter degraded. 1046
070715 W Fewer SAS ports operational. 1046
070717 W SAS ports degraded. 1046
070718 W SAS port connected to unsupported device. 1669
070720 W Ethernet adapter missing. 1045
070721 E Ethernet adapter failed. 1046
070722 E Ethernet adapter PCI error. 1046
070723 E Ethernet adapter degraded. 1046
070724 W Fewer Ethernet ports. 1046
070730   Bus adapter missing. 1192
070731   Bus adapter failed. 1192
070732   Bus adapter PCI error. 1192
070733   Bus adapter degraded. 1192
070734 W71 Inter-canister PCIe link not operational. 1006
070747 W Technician connected. 747
070760 E Voltage fault. 1110
070761 E Voltage high. 1100
070762 E Voltage low. 1105
070765 E Service Processor shows fan failure. 1089
070768 W Ambient temperature warning. 1094
070769 W CPU temperature warning. 1093
070770 W Shutdown temperature reached. 1092
070830 W Encryption key required. 1328
070831 W Encryption key invalid. 2555
070832 W Encryption key not found. 2555
070833 W USB device (such as hub) unsupported. 2555
070836 W Encryption key required. 1328
070842 W Fibre Channel IO port mapping failed. 1059
070860 W Fibre-channel network fabric is too big. 1800
070865, 071865, 073865, 075865 W Management IP port is not available on this node. 865
070880, 071880, 073880 E All or few RDMA sessions on the node in a system involved in short distance partnership using RDMA, are in disconnected state. 2024
071500 W Incorrect enclosure. 1021
071501 E Incorrect slot. 1192
071502 E No enclosure id and cannot get status from partner. 1192
071503 E Incorrect enclosure type. 1192
071504 E No enclosure id and partner matches. 1192
071505 E No enclosure id and partner has cluster data that does not match. 1192
071506 E No enclosure id and no cluster state on partner. 1192
071507 E No enclosure id and no cluster state. 1192
071508 W Cluster id different between enclosure and node. 1023
071509 E Cannot read enclosure identity. 1036
071510 E The detected memory size does not match the expected memory size. 1032
071513 E Uncorrectable memory error was detected. 1022
071522 E The system board processor has failed. 1034
071523 E Internal disk file system is damaged. 1187
071524 E Unable to update BIOS settings. 1034
071525 E Unable to update system board service processor firmware. 1034
071528 W Ambient temperature too high while system starting. 1092
071535 E Canister internal PCIe switch failed. 1034
071541 E Multiple hardware failures. 1184
071542 E A processor failed. 1024
071543 E No usable persistent data was found on the boot drives. 1035
071545 E Boot drive and system board do not match. 1035
071546 E Model ID mismatch between node and boot drive. 1192
071547 E Pluggable TPM is missing or broken. 1051
071548 E The node has compression hardware configured but no compression hardware is available. 1046
071549 E The node's compression hardware failed. 1046
071550 W Cannot form cluster due to lack of cluster resources. 1192
071551 W Cannot form cluster due to lack of cluster resources, overridequorum possible. 1192
071556 W Duplicate WWNN detected on SAN. 1133
071562 E The node's hardware configuration does not meet minimum requirements. 1034
071564 W Too many software failures. 1188
071565 E The node's internal drive is failing. 1032
071566 E The node's internal drive is failing. 1030
071568 E Unable to upgrade adapter firmware. 1469
071569 E CPU over temp. 1032
071573 E Node software inconsistent. 1187
071574 E Node software is damaged. 1187
071576 E Cluster state and configuration data cannot be read 1032
071578 E State data was not saved on power loss 1194
071671 W The available battery charge is not enough to allow the node canister to start . Two batteries are charging. 1176
071672 W The available battery charge is not enough to allow the node canister to start . One battery is charging. 1176
071673 E The available battery charge is not enough to allow the node canister to start . No batteries are charging. 1004
071690 W Node held in service state 1189
071700 W Fibre Channel adapter missing 1045
071701 E Fibre Channel adapter failed 1046
071702 E Fibre Channel adapter PCI error 1046
071703 E Fibre Channel adapter degraded 1046
071704 W Fewer Fibre Channel ports operational. 1061
071705 W Fewer Fibre Channel I/O ports operational. 1450
071706 W Fibre Channel clustered system path failure. 1550
071710 W SAS adapter missing 1045
071711 E SAS adapter failed 1046
071712 E SAS adapter PCI error 1046
071713 E SAS adapter degraded 1046
071715 W Fewer SAS ports operational 1034
071717 W SAS ports degraded. 1034
071718 W SAS port connected to unsupported device. 1669
071720 W Ethernet adapter missing 1045
071721 E Ethernet adapter failed 1046
071722 E Ethernet adapter PCI error. 1046
071723 E Ethernet adapter degraded 1046
071724 W Fewer Ethernet ports 1401
071730 W Bus adapter missing 1032
071731 E Bus adapter failed 1032
071732 E Bus adapter PCI error 1034
071733 E Bus adapter degraded. 1034
071734 W Inter-canister PCIe link not operational. 1006
071743 E Boot drive missing, out of sync, or failed. 1213
071744 E A boot drive is in the wrong location. 1214
071745 E Boot drive is in an unsupported slot. 1472
071746 W Technician port connection is not valid. 3024
071747 W Technician connected. 747
071755 E The CPLD is degraded 1032
071765 E Service Processor shows fan failure. 1089
071768 W Ambient temperature warning 1094
071769 W CPU temperature warning 1093
071773 E Cannot communicate with the PSU. 1123
071774 E PSU indicates an output failure. 1126
071775 E PSU failed. 1124
071776 E PSU has indicated input power failure. 1138
071777 E PSU is not installed correctly. 1127
071779 W Battery is missing. 1129
071780 E Battery has failed. 1130
071781 W Battery is below the minimum operating temperature. 1476
071782 W Battery is above the maximum operating temperature. 1475
071783 E Battery has a communications error. 1109
071784 W Battery is nearing end of life. 1474
071787 E Battery is at a hardware revision level not supported by the current code level. 1473
071790 E The midplane has a non-fatal issue. 1008
071810 W Battery cold 1156
071782 W Battery hot. 1157
071786 E Battery VPD checksum 1154
071788 E One or more DIMM temperature sensors failed or cannot be read. 1022
071789 E One or more canister temperature sensors failed or cannot be read. 1032
071820 W Node canister has the incorrect model for the enclosure. 3020
071821 E Ambient temperature sensor fault 1008
071830 W Encryption key required 1328
071831 W Encryption key invalid 2555
071832 W Encryption key not found 2555
071833 W USB device (such as hub) unsupported 2555
071836 W Encryption key required 1328
071840 W Detected hardware is not a valid configuration. 1198
071841 W Detected hardware needs activation. 1199
071850 W Canister battery is nearing the end of life 1159
072001 E System board has more or less processors detected. 1020
072500 W Incorrect enclosure. 1021
072501 E Incorrect slot. 1192
072502 E No enclosure id and cannot get status from partner. 1192
072503 E Incorrect enclosure type. 1192
072504 E Enclosure id and partner does not match. 1192
072505 E No enclosure id and partner has cluster data that does not match. 1192
072506 E No enclosure id and no cluster state on partner. 1192
072507 E No enclosure id and no cluster state. 1192
072508 W Cluster id is different between enclosure and node. 1023
072509 E Cannot read enclosure identity. 1036
072510 E The detected memory size does not match the expected memory size. 1032
072522 E The system board processor has failed. 1033
072523 E Internal disk file system is damaged. 1187
072525 E Unable to update system board service processor firmware. 1034
072535 E Canister internal PCIe switch failed. 1192
072541 E Multiple hardware failures. 1184
072550 W Cannot form cluster due to lack of cluster resources. 1192
072551 W Cannot form cluster due to lack of cluster resources, overridequorum possible. 1192
072556 E Duplicate WWNN detected on SAN. 1133
072562 E The node's hardware configuration does not meet minimum requirements. 1034
072564 E Too many software failures. 1188
072565 E The node's internal drive is failing. 1032
072569 E CPU over temp. 1032
072573 E Node software inconsistent 1187
072574 E Node software is damaged. 1187
072576 E Cluster state and configuration data cannot be read. 1032
072578 E State data was not saved on power loss. 1194
072651 W The canister battery is missing. 1153
072652 E The canister battery has failed. 1154
072655 E Canister battery communications error. 1158
072690 W Node held in service state 1189
072700 W Fibre Channel adapter missing 1045
072701 E Fibre Channel adapter failed 1046
072702 E Fibre Channel adapter PCI error 1046
072703 E Fibre Channel adapter degraded 1046
072705 W Fewer Fibre Channel I/O ports operational. 1450
072706 W Fibre Channel clustered system path failure. 1550
072710 W SAS adapter missing. 1045
072711 E SAS adapter failed. 1046
072712 E SAS adapter PCI error. 1046
072713 E SAS adapter degraded. 1046
072715 W Fewer SAS ports operational. 1046
072717 W SAS ports degraded. 1046
072718 W SAS port connected to unsupported device. 1669
072720 W Ethernet adapter missing. 1045
072721 E Ethernet adapter failed . 1046
072722 E Ethernet adapter PCI error. 1046
072723 E Ethernet adapter degraded. 1046
072724 W Fewer Ethernet ports 1402
072730 W Bus adapter missing 1032
072731 E Bus adapter failed 1032
072732 E Bus adapter PCI error 1032
072733 E Bus adapter degraded. 1032
072734 W Fewer bus ports are operational. 1006
072766 E CMOS error. 1670
072840 W A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. 1198
072841 W A supported hardware change was made to this node. User action is required to activate the new hardware. 1199
072850 W Canister battery is nearing end of life. 1159
072860 W Fibre-channel network fabric is too big. 1800
072900 E There was a PCIe link failure between canisters. 1006
072901 E The PCIe link is degraded between canisters. 1052
072902 E Inter-canister PCIe link recovered. 1006
072911 E The PCIe link for the CPU is degraded. 1034
073003 W The Fibre Channel ports are not operational. 1060
073005 E System path has a failure. 1550
073006 W The SAN is not correctly zoned. As a result, more than 512 ports on the SAN have logged into one system port. 1800
073007 W There are fewer Fibre Channel ports operational than are configured. 1061
073305 W Fibre Channel speed has changed. 1065
073310 E Duplicate Fibre Channel frame is detected. 1203
073402 E The Fibre Channel adapter has a failure. 1032
073404 E Fibre Channel adapter has detected PCI bus error. 1032
073500 W Incorrect enclosure. 1021
073501 E The canister position is not correct. 1192
073502 E No enclosure id and cannot get status from partner 1192
073503 E The enclosure type is not correct. 1192
073504 E The enclosure identity and partner does not match. 1192
073505 E No enclosure id and partner has cluster data that does not match 1192
073506 E The state and enclosure identity cannot be detected on the partner. 1192
073507 E The enclosure identity and node state cannot be detected. 1192
073508 W The system identity is different on the enclosure and the node. 1023
073509 E The enclosure identity cannot be read. 1036
073510 E Detected memory size does not match the expected memory size. 1032
073512 E Enclosure VPD is inconsistent. 1008
073513 E Uncorrectable memory error was detected. 1022
073522 E The system board service processor has failed. 1034
073523 W The internal disk file system of the node is damaged. 1187
073524 E Unable to update BIOS settings. 1034
073525 E Unable to update the service processor firmware of the system board. 1034
073528 E Ambient temperature is too high during system startup. 1098
073535 E The internal PCIe switch of the node canister failed. 1034
073541 E Multiple hardware failures. 1184
073550 W System cannot be created because of lack of resources. 1192
073551 W Cannot form cluster due to lack of cluster resources, overridequorum possible. 1192
073556 W Duplicate WWNN are detected on the SAN. 1133
073562 E The node hardware does not meet the minimum requirements. 1034
073564 W Too many software failures. 1188
073565 E The internal drive of the node is failing. 1032
073568 E Unable to upgrade adapter firmware. 1469
073569 E CPU over temp. 1032
073573 E Node software inconsistent (not raised on this product). 1187
073574 E The system data cannot be read. 1187
073576 E Cluster state and configuration data cannot be read. 1032
073578 E The system data was not saved when power was lost. 1194
073651 E The canister battery is missing. 1153
073652 E The canister battery has failed. 1154
073653 E The canister battery's temperature is too low. 1156
073654 E The canister battery's temperature is too high. 1157
073655 E The canister has a battery communications fault. 1158
073656 E The canister battery has insufficient charge. 1184
073690 W Node held in service state. 1189
073700 E The Fibre Channel adapter is missing. 1045
073701 E The Fibre Channel adapter failed. 1046
073702 E The Fibre Channel adapter has a PCI error. 1046
073703 E The Fibre Channel adapter is degraded. 1045
073704 W Fewer Fibre Channel ports are operational. 1061
073705 W Fewer Fibre Channel I/O ports are operational. 1450
073710 E The SAS adapter is missing. 1045
073711 E The SAS adapter has failed. 1046
073712 E The SAS adapter has a PCI error. 1046
073713 E The SAS adapter is degraded. 1046
073715 W Fewer SAS ports are operational. 1046
073717 W SAS ports degraded. 1046
073718 W SAS port connected to unsupported device. 1669
073720 E The Ethernet adapter is missing. 1045
073721 E The Ethernet adapter has failed. 1046
073722 E Ethernet adapter PCI error. 1046
073723 E Ethernet adapter degraded. 1046
073724 W Fewer Ethernet ports are operational. 1401
073730 E The bus adapter is missing. 1032
073731 E The bus adapter has failed. 1032
073732 E The bus adapter has a PCI error. 1032
073733 E The bus adapter is degraded. 1032
073734 W The inter-canister PCIe has a link failure. 1006
073748 W Technician port remains enabled. 741
073765 E Service Processor shows fan failure. 1192
073766 E CMOS error. 1670
073768 W Ambient temperature warning. 1094
073769 W CPU temperature warning. 1093
073776 E Power supply mains cable unplugged. 1192
073820 W The node canister has detected that it has a hardware type that is not compatible with the control enclosure MTM. 3020
073821 E Ambient thermal sensor fault 1500
073830 W Encryption key required 1328
073831 W Encryption key invalid 2555
073832 W Encryption key not found 2555
073833 W USB device (such as hub) unsupported 2555
073836 W Encryption key required 1328
073840 E Detected hardware is not a valid configuration. 1198
073841 E Detected hardware needs activation. 1199
073850 W Canister battery is nearing end of life 1159
073860 W The fabric is too large. 1800
074001 W System is unable to determine VPD for a FRU. 2040
074002 E The node warm started after a software error. 2030
074003 W A connection to a configured remote system has been lost because of a connectivity problem. 1715
074004 W A connection to a configured remote system has been lost because of too many minor errors. 1716
074500 W Incorrect enclosure. 1021
074501 E Incorrect slot. 1192
074502 E No enclosure id and cannot get status from partner. 1192
074503 E Incorrect enclosure type. 1192
074504 E Enclosure id and partner does not match. 1192
074505 E No enclosure id and partner has cluster data that does not match. 1192
074506 E No enclosure id and no cluster state on partner 1192
074507 E No enclosure id and no cluster state 1192
074508 W Cluster id different between enclosure and node 1023
074509 E Cannot read enclosure identity 1043
074510 E The detected memory size does not match the expected memory size 1039
074512 E Enclosure VPD is inconsistent 1029
074521 E Unable to detect any fibre-channel adapter 1192
074522 E The system board processor has failed 1088
074523 E Internal disk file system is damaged 1187
074524 E Unable to update BIOS settings 1034
074525 E Unable to update system board service processor firmware 1192
074528 W Ambient temperature too high while system starting 1087
074534 E System board fault 1039
074535 E Canister internal PCIe switch failed 1034
074536 E A device on the system board is too hot 1192
074538 E PCI Riser too hot 1192
074541 E Multiple hardware failures 1184
074550 W Cannot form cluster due to lack of cluster resources 1192
074551 W Cannot form cluster due to lack of cluster resources, overridequorum possible 1192
074556 W Duplicate WWNN detected on SAN 1133
074562 E The node's hardware configuration does not meet minimum requirements 1034
074564 E Too many software failures 1188
074565 E The node's internal drive is failing. 1039
074569 E CPU over temp. 1192
074573 E Node software inconsistent 1192
074574 E Node software is damaged 1187
074576 E Cluster state and configuration data cannot be read 1039
074578 E State data was not saved on power loss 1194
074650 W The canister battery is not supported. 1192
074651 W The canister battery is missing. 1192
074652 E The canister battery failed. 1192
074653 W The canister battery is below minimum operating temperature. 1192
074654 W The canister battery is above maximum operating temperature. 1192
074655 E Canister battery communications error. 1192
074656 W Canister battery has insufficient charge to support a fire hose dump. 1192
074657 E Not enough battery to support graceful shutdown. 1111
074690 W Node held in service state 1189
074710 W SAS adapter missing. 1192
074711 E SAS adapter failed 1192
074712 E SAS adapter PCI error 1192
074713 E SAS adapter degraded 1192
074715 W Fewer SAS ports operational 1192
074717 W SAS ports degraded 1192
074718 W SAS port connected to unsupported device 1669
074720 W Ethernet adapter missing 1039
074721 E Ethernet adapter failed 1039
074722 E Ethernet adapter PCI error 1034
074723 E Ethernet adapter degraded 1034
074724 W Fewer Ethernet ports 1401
074730 W Bus adapter missing 1039
074731 E Bus adapter failed 1039
074732 E Bus adapter PCI error 1034
074733 E Bus adapter degraded 1034
074734 W Fewer bus ports are operational 1007
074768 W Ambient temperature warning 1099
074830 W Encryption key required 1328
074831 W Encryption key invalid 2555
074832 W Encryption key not found 2555
074833 W USB device (such as hub) unsupported 2555
074840 W A hardware change was made that is not supported by software. User action is required to repair the hardware or update the software. 1198
074841 W A supported hardware change was made to this node. User action is required to activate the new hardware. 1199
075510 W Memory errors were detected. 510
075542 W CPU errors were detected. 542
075721 W Network adapter errors were detected. 721
075743 W A hardware error was detected on the boot disk. 743
075775 W One or more power supply units stopped working. 775
076001 E The internal disk for a node has failed. 1030
076002 E The hard disk is full and cannot capture any more output. 2030
076101 E Excessive correctable memory errors were detected. 1022
076401 E One of the two power supply units in the node has failed. 1096
076402 E One of the two power supply units in the node cannot be detected. 1096
076403 E One of the two power supply units in the node is without power. 1097
076502 E The PCIe lanes on a high-speed SAS adapter are degraded. 1121
076503 E A PCI bus error occurred on a high-speed SAS adapter. 1121
076504 E A high-speed SAS adapter requires a PCI bus reset. 1122
076505 E The SAS adapter has an internal fault. 1121
076511 E A high-speed SAS controller is missing. 1032
076512 E The PCIe lanes on a high-speed SAS adapter are degraded. 1032
076513 E A PCI bus error occurred on a high-speed SAS adapter. 1032
076514 E A high-speed SAS adapter requires a PCI bus reset. 1034
079500 W The limit on the number of system secure shell (SSH) sessions has been reached. 2500
079501 W Unable to access the Network Time Protocol (NTP) network time server. 2700
079503 W Unable to connect to NTP server that has been automatically configured. 2702
079504 W Hardware configurations of nodes differ in an I/O group. 1470
079505 W Stretch cluster reconfiguration is required to restore a dual site configuration 1178
079508 W Performance not optimized for V9000 variants without managed enclosures. 3300
079509 W Performance not optimized for V9000 variants with managed enclosures. 3300
079510 W Node has USB ports enabled 2065
079602 W Patch installation failed 4400
079603 W Patch auto-update server communication error 4401
081002 E An Ethernet port failure has occurred. 1401
082001 E A server error has occurred. 2100
083001 E System failed to communicate with UPS. 1145
083004 E UPS battery has a fault. 1180
083006 E UPS frame has a fault. 1175
083007 E UPS is overcurrent. 1160
083009 E The UPS has detected an input power fault. 1140
083010 E UPS has a cabling error. 1150
083013 E UPS crossed-cable test is bypassed because of an internal UPS software error. 3010
084000 W An array MDisk has deconfigured members and has lost redundancy. 1689
084001 W Array mdisk cannot copyback due to degraded RAID status 1679
084050 W An array MDisk is expected to fail within six months due to limited write endurance of member drives 3060
084100 E An array MDisk is corrupt because of lost metadata. 1240
084200 W Array MDisk has taken a spare member that does not match array goals. 1692
084201 W An array has members that are located in a different I/O group. 1688
084300 W An array MDisk is no longer protected by an appropriate number of suitable spares. 1690
084301 W No spare protection exists for one or more array MDisks. 1690
084302 W Distributed array MDisk has fewer rebuild areas available than threshold. 1690
084400 W A background scrub process has found an inconsistency between data and parity on the array. 1691
084420 W Array MDisk has been forced to disable hardware data integrity checking on member drives. 2035
084500 E An array MDisk is offline. The metadata for the inflight writes is on a missing node. 1243
084600 E An array MDisk is offline. Metadata on the missing node contains needed state information. 1243
084700 W Array response time too high. 1750
084701 W Distributed array MDisk member slow write count threshold exceeded. 1750
084800 E Distributed array MDisk offline due to I/O timeout. 1340
084801 E Array is using reserved physical capacity, recovery of redundancy might be compromised 2090
085047 W Battery reconditioning is required but not possible. 1131
085048 W Battery reconditioning required 2060
085052 E Interface adapter has degraded PCI link 1039
085063 E Canister is missing an interface adapter 1045
085091 W External iSCSI port not operational 1403
085092 W Too many ISCSI host logins 1803
085118 W System update halted 2010
085160 W Check the air filter 1820
085161 E Array data compromised 1048
085198 W Too many enclosures visible on fabric 1807
085199 W Enclosure visible on fabric managed by another system 1706
085200 W Cabling error. Internal cabling connectivity has changed. 1440
085201 W Enclosure connectivity undetermined. Connectivity to an enclosure can no longer be determined 1440
085202 W Minimal enclosure connectivity not met. 1705
085203 W Config node cannot communicate with canister. 1034
085204 W Managed enclosure is not visible from config node. 1042
085205 W Canister internal error. 1705
085222 W Write failed to USB Flash Drive 1790
085336 E Flash module is manually marked for repair. 1741
085369 E System Shutdown N/A
085370 E Internal encryption key is not valid or does not exist. 1048
086001 E Encryption key unavailable 1739
086002 W Encryption key on USB flash drive removed 2550
086003 W Write to USB Flash Drive failure 1790
086005 W Encryption not committed 1780
086006 W Key Server reported KMIP error 1785
086007 W Key Server reported vendor information error 1785
086008 W Failed to connect to Key Server 1785
086009 W Key Server reported misconfigured primary. 1785
086010 W The encryption function is enabled, but only a recovery key is configured. 1786
086012 W The maximum attempts to regenerate internal key (rekey) has failed. 1788
086013 W The Internal Key Management method is enabled along with External Key Management method such as USB or Key Server. 1789
086014 W The Internal Key Management method is enabled, but Encryption Recovery Key is not configured. 1791
086015 W The Internal Key Management method is enabled, but Encryption Recovery Key is not configured. 1790
087001 E Cloud gateway service restarted 2031
087002 E Cloud gateway service restarted too often 1404
087003 W Cloud account SSL certificate will expire within the next 30 days 3140
087004 W Cloud account not available, cannot resolve hostname 1580
087005 W Cloud account not available, cannot contact cloud provider 2310
087006 W Cloud account not available, cannot communicate with cloud provider 2320
087007 W Cloud account not available, no matching CA certificate 2300
087008 W Cloud account not available, expired SSL certificate 2300
087009 W Cloud account not available, cannot establish secure connection with cloud provider 3100
087010 W Cloud account not available, cannot authenticate with cloud provider 2330
087011 W Cloud account not available, cannot obtain permission to use cloud storage 2330
087012 W Cloud account not available, cannot complete cloud storage operation 3100
087013 W Cloud account not available, cannot access cloud object storage 2105
087014 W Cloud account not available, incompatible object data format 3135
087016 W Cloud account not available, cloud object storage encrypted 1656
087017 W Cloud account not available, cloud object storage not encrypted 1656
087018 W Cloud account not available, cloud object storage encrypted with the wrong key 1657
087019 W No permission to use cloud storage snapshot operation 2305
087020 W Cloud account out of space during cloud storage snapshot operation 2125
087021 W Cannot create container object to cloud object storage during cloud snapshot operation 2305
087022 W A cloud object could not be found during cloud snapshot operation. 3108
087023 W A cloud object was found to be corrupt during cloud snapshot operation. 3108
087024 W A cloud object was found to be corrupt during cloud snapshot decompression operation. 3108
087025 W Etag integrity error during cloud snapshot operation 3108
087026 W Internal Read error during cloud snapshot operation 2120
087027 W Unexpected error occurred, cannot complete cloud snapshot operation 3108
087028 W No permission to use cloud snapshot restore operation 2305
087029 W A cloud object was not found during a cloud snapshot restore operation. 3108
087030 W A cloud object was found to be corrupt during a cloud snapshot restore operation 3108
087031 W A cloud object was found to be corrupt during a cloud snapshot restore decompression operation 3108
087032 W Etag integrity error during cloud snapshot restore operation 3108
087033 W Internal write error during cloud snapshot operation 2120
087034 W Cannot create bad blocks on a managed disk during cloud snapshot restore operation. 3108
087035 W Unexpected error occurred, cannot complete cloud snapshot restore operation 3108
087036 W No permission to use cloud snapshot delete operation 2305
087037 W A cloud object was not found during a cloud snapshot delete operation. 3108
087038 W A cloud object was found to be corrupt during cloud snapshot delete operation 3108
087039 W A cloud object was found to be corrupt during cloud snapshot delete decompression operation 3108
087040 W Unexpected error occurred, cannot complete cloud snapshot delete operation 3108
087044 W Cloud account out of space during cloud snapshot restore commit operation 2125
087045 W Cloud account out of space during cloud snapshot delete operation 2125
087046 W Transparent Cloud Tiering feature license limit exceeded. 3032
087048 W Too many node restarts have occurred, cloud backup operations paused 3104
087049 W Internal FlashCopy error on volume enabled for cloud snapshots. 2118
088000 E SCSI or NVMeFC NPIV host port failed to login to fabric 1300
088001 E A fibrechannel target port mode transition was not successful 1300
088002 W Equivalent fibre channel ports are reporting that they are connected to different fabrics 3220
088003 W A spare node in this cluster is not providing additional redundancy 1380
088004 W A spare node could not be automatically removed from the cluster 3180
089001 W Single PSU failure in bare metal server 1810
089002 W Node IP missing, only single path connection available between nodes 1811
089003 W The IP connections between nodes were broken 1812
089004 W A node rejoined cluster with identity changed 1813
089005 E The node is not authorized to perform an operation. 1817
089006 E The node operation failed because of network security rules. 1818
090000 E NVMe drive port offline due to errors 1685
090001 E NVMe drive offline due to excessive processing time 1685
090002 E NVMe drive offline 1685
090003 E NVMe drive over temperature 1095
090004 E NVMe drive is reporting expected failure 1680
090005 E NVMe drive is reporting excessive media errors 1680
090006 E NVMe drive is experiencing excessive timeouts 1680
090007 E NVMe drive slow detected 1680
090008 E NVMe drive detecting too many T10dif errors 1680
090009 E NVMe drive slow detected 1680
090010 E NVMe drive is reporting end of life due to flash degradation 1680
090011 W NVMe unsupported drive inserted 1666
090012 W NVMe drive requires formatting 1206
090013 W NVMe drive requires formatting due to incorrect data protection type 1206
090015 W NVMe drive temperature warning 1098
090016 W NVMe drive media error 1321
090017 W NVMe drive error recovery procedure occurred 1685
090018 W NVMe drive reported t10 data protection error 1322
090019 W NVMe drive experienced timeout 1340
090020 W Too many NVMe drives attached to the system 1179
090021 W NVMe drive firmware download failed 3090
090022 W NVMe quorum disk is unavailable 1335
090023 E NVMe drive is behaving out-of-specification and is likely faulty 1215
090024 W NVMe drive experienced timeout 1340
090025 W NVMe Flash Core Module is experiencing excessive hardware errors. 1680
090026 E NVMe drive port is offline.  
090027 E Drive offline because it is locked by a missing encryption key. 1674
090028 E NVMe drive is reporting a degraded PCIe link speed 1686
090029 E NVMe drive is reporting a degraded PCIe link width 1686
090030 E NVMe drive is reporting excessive PCIe link errors 1215
090031 W SCM NVMe drive is in an incorrect slot. 3415
090032 W NVMe drive secure erase failed 3340
090033 E NVMe drive encryption error 1674
090034 E NVMe drive encryption timeout 1674
090035 W Drive firmware download process skipped drives by recommendation of the update test utility. 3360
090036 W A volume received an anomalous workload due to new application configuration (encryption enabled) or a result of a security threat such as ransomware. 4300
090037 W A volume in the volume group received an anomalous workload due to new application configuration (encryption enabled) or a result of a security threat such as ransomware. 4300
091000 W LD: Managed EBS is detached from web console.LD: Managed disk is detached from web console. 1814
091001 W LD: Managed EBS is deleted from web console.LD: Managed disk is deleted from web console. 1815
091002 W LD: Managed EBS tag is changed by user.LD: Managed disk tag is changed by the user. 1340
091003 W LD: Local mdisk offline due to IO timeout. 1816
987303 E Compression suspended too many times. 3400
989001 W Managed Disk Group space warning. 1866
989007 W Unable to send to the cloud callhome servers 3201
989058 E Storage partition migration completed successfully  

Error code reference

Error codes are listed in numerical order.