Configuration not replaced with stream or baseline from global configuration
Problem: In a global configuration, you replace a configuration contributed by an IBM® Engineering Lifecycle Management application; for example, you replace a Requirements Management (RM) stream with a baseline. When you return to RM with the global configuration set as the configuration context, you see the stream instead of the baseline as the Project Area Configuration. This process can take up to five seconds.
Solution: Administrators can change the cache update from asynchronous to synchronous modes. A full description of the problem and solution is available in Server settings for configuration management.