Troubleshooting IBM Engineering Workflow Management ISPF client PassTicket support
This section provides information to help you troubleshoot problems with the IBM® Engineering Workflow Management ISPF client PassTicket setup.
Check the following items to ensure that they are correct:
- The BLZPASTK module is defined in the PTKTDATA list. For more information, see the _ISPF_DAEMON_APPLID=BLZAPPL definition in ISPF daemon configuration file (ispfdmn.conf).
- The PTKTDATA RACF class is activated. For more information, see Build System Toolkit RACF classes in Security for the Build System Toolkit and Rational Build Agent on z/OS systems.
- The SBLZAUTH is defined in the LNKLST definitions or included on a STEPLIB DD statement in the LOGON procedure. For more information, see the LNKLST definitions in PROGxx section under PARMLIB changes in Installation information for z/OS system programmers.
- The SBLZAUTH data set is APF-authorized. If SBLZAUTH is on SMS, you must use the SMS parm on the SETPROG APF,ADD command. If SBLZAUTH is not on SMS, you must use the VOLUME=xxxxxx format on the SETPROG APF,ADD command. The SETPROG command does not give you any indication that a problem exists if you do not use the correct parameters. For more information, see the APF authorizations in PROGxx section under PARMLIB changes in Installation information for z/OS system programmers.