JDBC log source parameters for IBM Proventia Management SiteProtector

If QRadar does not automatically detect the log source, add an IBM® Proventia Management SiteProtector log source on the QRadar Console by using the JDBC protocol.

When using the JDBC protocol, there are specific parameters that you must use.

The following table describes the parameters that require specific values to collect JDBC events from IBM Proventia Management SiteProtector:
Table 1. JDBC log source parameters for the IBM Proventia Management SiteProtector DSM
Parameter Value
Log Source type IBM Proventia Management SiteProtector
Protocol Configuration JDBC
Log Source Identifier

Type a name for the log source. The name can't contain spaces and must be unique among all log sources of the log source type that is configured to use the JDBC protocol.

If the log source collects events from a single appliance that has a static IP address or host name, use the IP address or host name of the appliance as all or part of the Log Source Identifier value; for example, 192.168.1.1 or JDBC192.168.1.1. If the log source doesn't collect events from a single appliance that has a static IP address or host name, you can use any unique name for the Log Source Identifier value; for example, JDBC1, JDBC2.

For a complete list of JDBC protocol parameters and their values, see JDBC protocol configuration options.