APC UPS
The IBM QRadar DSM for APC UPS accepts syslog events from the APC Smart-Uninterruptible Power Supply (UPS) family of products.
Restriction: Events from RC-Series Smart-UPS are not supported.
The following table identifies the specifications for the APC UPS DSM:
Specification | Value |
---|---|
Manufacturer | APC |
DSM name | APC UPS |
RPM file name | DSM-APCUPS-Qradar_version-build_number.noarch.rpm |
Protocol | Syslog |
Recorded event types | UPS events Battery events Bypass events Communication events Input power events Low battery condition events SmartBoost events SmartTrim events |
Automatically discovered? | No |
Includes identity? | No |
Includes custom properties? | No |
More information | APC website (http://www.apc.com) |
To send APC UPS events to QRadar, complete the following steps:
- If automatic updates are not enabled, download and install the most recent version of the APC UPS DSM RPM from the IBM® Support Website onto your QRadar Console.
- Create an APC UPS log source on the QRadar
Console and use the following table to
configure the specific values that are required to collect APC UPS events:
Table 2. APC UPS log source parameters Parameter Value Log Source type APC UPS Protocol Configuration Syslog - Configure your APC UPS device to forward syslog events to QRadar.