IQIMT009WCANNOT REUSE ACTIVE MONITOR SYSTEM CONTROL AREA AT: X'<addr>'
Explanation
IQIMONTR failed to reuse an unreleased Monitor-System-Control-Area created by a
previous IQIMONTR job that got prematurely terminated. The existing Monitor-System-Control-Area is
still in an undetermined active state.
System action
IQIMONTR resumes normal processing.
System programmer response
Restart the monitor job by appending a ",NEW" keyword to the IQIMONTR EXEC
PARM character string. If the error recurs and the program is not in error, look at the messages in
the job log for more information. Search problem reporting data bases for a fix to the problem. If
no fix exists, contact the https://www.ibm.com/mysupport/s/?language=en_US. Provide the JCL and all printed output and output data sets
related to the problem.
Descriptor code
<addr>
The 8-digit hexadecimal memory address of the previously created
Monitor-System-Control-Area.