IQIMT009W CANNOT REUSE ACTIVE MONITOR SYSTEM CONTROL AREA AT: X'<addr>'

Explanation

IQIMONTR failed to reuse an unreleased Monitor-System-Control-Area created by a previous IQIMONTR job that got prematurely terminated. The existing Monitor-System-Control-Area is still in an undetermined active state.

System action

IQIMONTR resumes normal processing.

System programmer response

Restart the monitor job by appending a ",NEW" keyword to the IQIMONTR EXEC PARM character string. If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix to the problem. If no fix exists, contact the https://www.ibm.com/mysupport/s/?language=en_US. Provide the JCL and all printed output and output data sets related to the problem.

Descriptor code

<addr>
The 8-digit hexadecimal memory address of the previously created Monitor-System-Control-Area.