CMUN

Storage management console server messages begin with the prefix CMUN.


CMUN00000E

Authentication failure.

Explanation

The management console server reports an authentication failure. Authentication information that is provided by the client is not valid.

User Response

Provide the correct user name and password, and then resubmit the task.


CMUN00001E

Configuration error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN00002E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN00003E

Configuration connection error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN00004E

Configuration connection error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN00005E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal Copy Services failure.

User Response

Contact your product technical support for assistance.


CMUN00006E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN00007E

Mismatched Jar file

Explanation

The management console server or your client software reports that one of the Java resource files is not the correct version. The client and server cannot operate correctly if their respective files are not the same version.

User Response

Install the appropriate versions of the management console server software and client software. If the problem persists, contact your product technical support for assistance.


CMUN00008E

Incorrect configuration parameter

Explanation

The management console server detects an incorrect or nonexistent configuration parameter. Incorrect configuration can include the following values.

  • A null value
  • An incorrect extent type
  • An incorrect volume type
  • An incorrect device type
  • An incorrect storage image
  • An out of range subsystem identifier

User Response

Correctly specify all parameters, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN00009E

Incorrect parameter

Explanation

The management console server detects an incorrect or nonexistent parameter. Incorrect parameters can include the following types of information.

  • An incorrect volume
  • An incorrect logical subsystem
  • An incorrect storage image

User Response

Correctly specify all parameters, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN00010E

Incorrect parameter.

Explanation

The management console server detects an incorrect parameter. Examples include.

  • A null value
  • An incorrect type

User Response

Correctly specify all parameters, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN00011E

A configuration query error has occurred. Unmatched dscli versions of the client and storage system may necessitate a client dscli upgrade.

Explanation

The dscli client version is too low to support small extent functions, or the management console server detected an internal error that occurred during a resource query.

User Response

Upgrade the client dscli, or contact your product technical support for assistance.


CMUN00012E

Configuration query error. Contact your product technical support for assistance.

Explanation

The management console server detects an internal error that occurs during a resource query.

User Response

Contact your product technical support for assistance.


CMUN00013E

Resource not found

Explanation

The management console server reports that it cannot find a resource. This might be because the resource is not configured on the console, or because it does not exist in the storage complex.

User Response

Check the available resources and specify the correct parameters. If the problem persists, contact your product technical support for assistance.


CMUN00014E

Server error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN00015E

Command execution timeout

Explanation

The management console server reports that an internal timeout has occurred before the task can complete.

User Response

Check for intermediate task results. Remove intermediate results or modify the task as necessary. Resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN00016E

Unauthorized access

Explanation

The management console server reports that you are not authorized to perform this operation.

User Response

Verify your user name and privileges. Contact your system administrator.


CMUN00017E

Your user ID does not have the authority to perform this operation.

Explanation

The management console server reports that your user ID is not authorized to perform this operation.

User Response

If your password has expired, renew your password. Verify that you have used the correct user ID to log in. Verify that the privileges for your user ID are correct. If the privileges for your user ID correctly deny authorization to perform this operation, contact a user who has authorization to perform this operation. If the privileges for your user ID incorrectly deny authorization to perform this operation, contact your system administrator to correct the privileges for your user ID.


CMUN00018E

Unable to connect to the management console server

Explanation

Your client software cannot connect to the management console server. This might be because the server is not enabled, a network problem exists, or the server is refusing connections because the maximum number of clients are connected already.

User Response

Ensure that the management console is online. Ensure that you specify the management console IP addresses correctly.


CMUN00019E

Unknown configuration error. Contact your product technical support for assistance.

Explanation

The management console server detects an unknown internal error that occurs during resource configuration.

User Response

Contact your product technical support for assistance.


CMUN00020E

Unknown error. Contact your product technical support for assistance.

Explanation

The management console server detects an unknown internal error.

User Response

Contact your product technical support for assistance.


CMUN00021E

Unknown management console server internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an unknown internal error.

User Response

Contact your product technical support for assistance.


CMUN00022E

The specified operation is unsupported.

Explanation

The management console server reports that the command that it received is unsupported. This might be because the command is not valid, because the client issuing the command is at a different software version level than the server, or because the operation is not licensed.

User Response

Verify that you are issuing the correct command. Verify that you have installed the same versions of the management console server software and the client. Verify that you have installed licensed machine code that supports the operation.


CMUN00023E

The external user account could not be authenticated because it cannot be mapped to a user resource scope with current resource scope mappings.

Explanation

No explicit user resource scope mapping exists for this external user account. In addition, this external user belongs to multiple external groups that are mapped to different and conflicting resource scopes.

User Response

Explicitly map the external user account to a resource scope, or resolve the conflicting group resource mappings, and reauthenticate.


CMUN00024E

The external user account could not be authenticated because it is mapped to both an admin group and a secadmin group.

Explanation

The user name, user group, or both, for the specified account are mapped to administrator and security administrator groups. The two group mappings are conflicting and preventing authentication.

User Response

Remove either the admin group mapping or the secadmin group mapping from the account, and reauthenticate.


CMUN00025E

The specified operation is unsupported because Copy Service Software PID is not installed.

Explanation

None.

User Response

None.


CMUN01000E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN01001E

Operation failure: retrieving rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN01002E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN01100E

The Rekey data key task has failed because an incorrect machine state exists. Contact your product technical support for assistance.

Explanation

An unexpected internal condition has been detected on the storage image.

User Response

Contact your product technical support for assistance.


CMUN01101E

The Rekey data key task has failed because the request is not compatible with the current configuration of the storage image. Contact your product technical support for assistance.

Explanation

The current configuration of the storage image does not support the Rekey data key request.

User Response

Contact your product technical support for assistance.


CMUN01102E

The Rekey data key task has failed because the value that you have specified for at least one of the encryption key labels is not correct.

Explanation

You must specify a valid value for each encryption key label that you specify when you submit this task.

User Response

Specify a valid value for each encryption key label that you specify when you submit the task.


CMUN01103E

The data key task has failed because the required number of key servers is not operating correctly.

Explanation

When you rekey a data key, all of the key servers must be operating correctly. When the storage image boots, at least two key servers must be operating correctly. When you relabel and update the certificate of a chosen key group either to an IBM certificate or customer generated certificate, all of the key servers must have the latest code that supports key retrieval with the target certificate type.

User Response

If you are attempting to rekey a data key, ensure that all of the key servers are operating correctly, and resubmit the task.

If you have received this message during the storage image power on procedure, ensure that at least two key servers are operating correctly, and continue the storage image power on procedure.

If you are attempting to relabel and update certificate of a chosen key group either to an IBM certificate or customer generated certificate, ensure that all of the key servers have the latest code that supports key retrieval with the target certificate type.


CMUN01104E

The Rekey data key task has failed due to a communication failure between the storage unit and the key server.

Explanation

The communication failure might be caused by a command not being sent to the key server, by a failure to establish communications, or by a reply not being received from the network interface within the expected amount of time.

User Response

Verify that the key server is configured and active. Verify that the communication path between the management console and the key server is active. If the problem persists, contact your product technical support for assistance.


CMUN01105E

The Rekey data key task cannot be initiated because the length of at least one of the key group key labels that you have specified is greater than 64 characters.

Explanation

The length of the key group key label cannot exceed 64 characters.

User Response

Ensure that each key group key label that you specify is no more than 64 characters in length, and resubmit the task.


CMUN01106E

The Rekey data key task cannot be initiated because the access recovery key for the specified key group is not in the Configured or Disabled state.

Explanation

The access recovery key for a key group must be in the Configured or the Disabled state when you rekey the data key.

User Response

Ensure that the access recovery key for the key group is in the Configured or Disabled state, and resubmit the task.


CMUN01107E

The Rekey data key task has failed due to a transient error. Resubmit the Rekey data key task. If the problem persists, Contact your product technical support for assistance.

Explanation

The transient error prevented the completion of the task.

User Response

Resubmit the Rekey data key task. If the problem persists, contact your product technical support for assistance.


CMUN01108E

The Rekey access recovery key task cannot be initiated because a Rekey data key task in progress.

Explanation

The Rekey access recovery key task cannot be initiated while a data key is being rekeyed.

User Response

Wait for the Rekey data key task to complete, and resubmit the Rekey access recovery key task.


CMUN01109E

The task cannot be initiated because the Easy Tier LIC feature key is not activated on the storage unit.

Explanation

To allow migration of a volume to another extent pool or to change the extent allocation method of a volume, the Easy Tier LIC feature key must be installed and activated on the storage image.

User Response

Ensure that the Easy Tier LIC feature key is installed and activated on the storage image, and resubmit the task.


CMUN01110E

The performance query task on logical partition zero (LPAR 0) has failed because the quality of service (QoS) server has not responded within the allotted time.

Explanation

The QoS server subtask has not completed within the expected amount of time. This might be caused by a large QoS server workload.

User Response

Wait a few minutes, and resubmit the task.


CMUN01111E

The performance query task on logical partition one (LPAR 1) has failed because the quality of service (QoS) server has not responded within the allotted time.

Explanation

The QoS server subtask has not completed within the expected amount of time. This might be caused by a large QoS server workload.

User Response

Wait a few minutes, and resubmit the task.


CMUN01112E

The quality of service (QoS) server on logical partition zero (LPAR 0) is not available. Contact your product technical support for assistance.

Explanation

A QoS server process on LPAR 0 is not functioning properly or does not exist.

User Response

Contact your product technical support for assistance.


CMUN01113E

The quality of service (QoS) server on logical partition one (LPAR 1) is not available. Contact your product technical support for assistance.

Explanation

A QoS server process on LPAR 1 is not functioning properly or does not exist.

User Response

Contact your product technical support for assistance.


CMUN01114E

The performance report task cannot be initiated because the specified start time is more recent than the specified end time.

Explanation

The time period that was specified for the performance report is not valid.

User Response

Specify an end time that is more recent than the start time, and resubmit the task.


CMUN01115E

The performance report task cannot be initiated because the calculated number of reports is not an integer. The number of reports is the duration of the time period divided by the interval.

Explanation

The number of reports must be a whole integer with no remainder. The duration of the report is the start time subtracted from the end time.

User Response

Ensure that the duration is a whole multiple of the interval, and resubmit the task.


CMUN01116E

The performance report task cannot be initiated because the filter ID is not correct.

Explanation

You must specify a valid performance report filter ID when you submit this task. Supported filter IDs include: Rank ID, Device Adapter (DA) pair ID and ESS ID.

User Response

Specify a valid filter ID, and resubmit the task.


CMUN01117E

The performance report task cannot be initiated because the number of reports that would be generated is greater than the supported maximum number of reports for a logical partition (LPAR) in a single request.

Explanation

The number of reports is calculated as the duration of the time period divided by the interval.

User Response

Increase the interval or decrease the duration so that a supported number of reports is requested, and resubmit the task.


CMUN01118E

The performance report task cannot be initiated because the number of reports that would be generated is greater than the supported maximum number of reports that the user can obtain with a single request.

Explanation

The number of reports is calculated as the duration of the time period divided by the interval.

User Response

Increase the interval or decrease the duration so that a supported number of reports is requested, and resubmit the task.


CMUN01119E

The requested task cannot be initiated because I/O Priority Manager is not enabled.

Explanation

You can enable I/O Priority Manager through Storage Manager or by specifying the -iopmmode parameter for the command chsi through the command-line interface (CLI). If the I/O Priority Manager Mode is set to Managed or ManagedSNMP, you also must install the I/O Priority Manager license activation key.

User Response

Enable I/O Priority Manager, and resubmit the task.


CMUN01120E

The task has failed because either the Device Adapter (DA) pair does not exist or the query to the DA pair has failed.

Explanation

The task submits a query. Either the DA pair that was specified in the query does not exist, or the query to the DA pair did not complete.

User Response

Specify an existing DA pair, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN01121E

The task cannot be initiated because the name of the control switch to be modified was not specified. Contact your product technical support for assistance.

Explanation

The Modify Storage Image task submits a subtask to update a control switch. The subtask was submitted without specifying which switch to modify.

User Response

Contact your product technical support for assistance.


CMUN01122E

The task cannot be initiated because the name of the control switch to be modified is not valid. Contact your product technical support for assistance.

Explanation

The Modify Storage Image task submits a subtask to update a control switch. The subtask was submitted using an incorrect switch name.

User Response

Contact your product technical support for assistance.


CMUN01123E

The task cannot be initiated because required information about the control switch to be modified cannot be obtained. Contact your product technical support for assistance.

Explanation

The Modify Storage Image task submits a subtask to update a control switch. The subtask cannot obtain control switch information that is required before the modification can be performed.

User Response

Contact your product technical support for assistance.


CMUN01124E

The Modify Storage Image task failed because a subtask could not modify the control switch, or could not record the new control switch information in the microcode.

Explanation

This error is caused when one LPAR is in a state, which may be temporary, that does not allow the control switch to be modified. The states that are valid for the control switch to be modified are both LPARs are online, or one LPAR is online and one LPAR is offline and not activated.

User Response

Wait a few minutes, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN01125E

The Assign rank to extent pool task has failed during the subtask that checks solid-state drive (SSD) and Flash drive restrictions. Contact your product technical support for assistance.

Explanation

The subtask that determines whether the required preconditions for the task are present has encountered an error.

User Response

Contact your product technical support for assistance.


CMUN01126E

The Assign rank to extent pool task cannot be initiated because a rank without solid-state drives (SSDs) or Flash drives cannot be assigned to a pool that has them with space-efficient storage.

Explanation

The assignment of a rank containing SSDs or Flash drives to a pool that already has them with space-efficient storage is not allowed.

User Response

Select an extent pool without SSDs or Flash drives and without space-efficient storage, and resubmit the task; otherwise, assign a different rank having SSDs or Flash drives and resubmit the task.


CMUN01127E

The Merge extent pools task has failed during the subtask that checks solid-state drive (SSD) and Flash drive restrictions. Contact your product technical support for assistance.

Explanation

The subtask that determines whether the required preconditions for the task are present has encountered an error.

User Response

Contact your product technical support for assistance.


CMUN01128E

The Merge extent pools task cannot be initiated because an extent pool that has solid-state drives (SSDs) or Flash drives with space-efficient storage cannot be merged.

Explanation

An extent pool is not eligible to be merged if it has SSDs or Flash drives with space-efficient storage.

User Response

Merge only extent pools without SSDs or Flash drives and without space-efficient storage.


CMUN01129E

The Merge extent pools task cannot be initiated because both the source and target extent pools have space-efficient storage.

Explanation

Either the source extent pool or the target extent pool can have space-efficient storage, but you cannot merge two extent pools that each has space-efficient storage.

User Response

Ensure that at most one of the two extent pools that you select to merge has space-efficient storage when you submit this task.


CMUN01130E

The Migrate volume task cannot be initiated because the volume is already being migrated, and in the Migration Paused volume configuration state.

Explanation

A volume that is being migrated cannot be selected for another migration until it is no longer being migrated.

User Response

Either resume the current paused migration and wait for it to complete and resubmit the task, or cancel the current paused migration and migrate the volume either to the paused migration's source or target extent pool.


CMUN01131E

The Migrate volume task cannot be initiated because the volume that you have selected has a volume configuration state of Migration Canceled, and therefore the volume can only be migrated to the source or target extent pool of the canceled migration task.

Explanation

The only valid extent pools to which you can migrate this volume are the source extent pool or the target extent pool of the canceled migration task.

User Response

Migrate the selected volume to either the source or target extent pool of the canceled migration and wait until that migration completes before you attempt to migrate the volume to a different extent pool.


CMUN01132E

The Migrate volume task cannot be initiated because the volume that you have selected has a volume configuration state that is not Normal, Migration error, or Migration Canceled.

Explanation

You can migrate a volume only if its volume configuration state is Normal, Migration error, or Migration Canceled.

User Response

Select a volume that is in a configuration state that is supported for the migration task when you submit this task.


CMUN01133E

The task cannot be initiated because at least one of the specified files does not exist or no files of the specified type were found.

Explanation

Examples of when this error will occur are:

  • When attempting to offload connection files and there are no connections defined.
  • When attempting to offload Easy Tier monitor data, the proper Easy Tier licensed feature key is not enabled and the Easy Tier monitor all option is not enabled.
  • When attempting to offload an SDO certificate, but the SDO task has not been submitted.

User Response

Ensure that the files that you request to offload exist, and resubmit the task.


CMUN01134E

The task cannot be initiated because the file set that you specified does not exist on the storage image.

Explanation

Only certain types of files can be offloaded using this task. This error can occur if the version of microcode that is installed on the storage image does not create the file set that you have requested to be offloaded. This error can also occur if the file set that you have specified is not of a type that is supported for this task by the version of microcode that is installed on the storage image. Examples of files that can be offloaded in this version of microcode are Easy Tier automatic mode data and audit log.

User Response

Ensure that the version of microcode that is installed on the storage image supports the offloading of the file set that you specify when you submit this task.


CMUN01135E

The task cannot be initiated because the destination server is offline.

Explanation

The server to which you offload the file must be online when you submit this task.

User Response

Ensure that the destination server is online when you submit this task.


CMUN01136E

The task has failed while attempting to write to the target directory on the destination server.

Explanation

An I/O error has occurred. This might be caused by incorrect write authentication for the user or target directory.

User Response

Ensure that the user has write authentication to the target directory, and resubmit the task.


CMUN01137E

The task cannot be initiated because the file that you have specified already exists on the target directory of the destination server and you did not specify the force overwrite option.

Explanation

When a file with the filename that you specify already exists in the target directory, you can only offload another file with the same name to the same directory if you specify the force overwrite option.

User Response

Specify a filename that does not already exist in the target directory or specify the force overwrite option, and resubmit the task.


CMUN01138E

The rekey data key task has failed because the values that were specified for the primary key label and the secondary key label are identical.

Explanation

You cannot use the same label for both the primary key and the secondary key for a key group.

User Response

Ensure that the primary key label and the secondary key label are unique, and resubmit the task.


CMUN01139E

The rekey data key task has failed because new values were not specified for the primary key label and the secondary key label, and the query to obtain current key labels has failed. Contact your product technical support for assistance.

Explanation

An error has occurred while attempting to retrieve current key label information that is required for the task.

User Response

Contact your product technical support for assistance.


CMUN01140E

The task to create the logical FB volume with the storage allocation method of track space-efficient (TSE) cannot be initiated because the performance group is not set to the default.

Explanation

The performance group specified for an FB volume with the TSE storage allocation method must be set or defaulted to FB performance group 0.

User Response

Create the TSE logical FB volume and specify performance group 0 or allow the performance group to be set by default.


CMUN01141E

The task to modify the logical FB volume cannot be initiated because the performance group is not set to an existing performance group.

Explanation

The performance group that is specified for the creation of a logical FB volume must be within the valid FB performance group range of 0-15.

User Response

Create the logical FB volume and specify a performance group that is within the valid range or allow the performance group to be set by default.


CMUN01142E

The task to create an logical alias volume cannot be initiated because the performance group is not set to the default.

Explanation

The performance group for an alias volume must be set or defaulted to performance group 16.

User Response

Create the alias volume and specify performance group 16 or allow the performance group to be set by default.


CMUN01143E

The task cannot be initiated because you cannot modify the performance group ID of a CKD alias volume to a value other than the default value of 0.

Explanation

The performance group ID of a CKD alias volume must be the default value of 0, and cannot be changed.

User Response

When you modify a CKD alias volume, do not modify its performance group ID.


CMUN01144E

The task cannot be initiated because you cannot modify the performance group ID of a track space-efficient volume to a value other than the default value of 0.

Explanation

The performance group ID of a fixed block volume that is track space-efficient must be the default value of 0, and cannot be changed.

User Response

When you modify a track space-efficient volume, do not modify its performance group ID.


CMUN01145E

The task to modify the logical FB volume cannot be initiated because the performance group of a FB volume must be set to an existing performance group.

Explanation

The performance group that is specified for the modification of a logical FB volume must be within the valid FB performance group range of 0-15.

User Response

Modify the logical FB volume and specify a performance group that is within the valid range.


CMUN01146E

The Modify logical volume task has failed at the device adapter level while attempting to modify the performance group ID. Contact your product technical support for assistance.

Explanation

A device adapter (DA) error was encountered while attempting to change the performance group ID.

User Response

Contact your product technical support for assistance.


CMUN01147E

The Modify extent allocation method task has failed because an error has occurred at the device adapter level. Contact your product technical support for assistance.

Explanation

The device adapter level subtask that modifies the extent allocation method has detected an error. The extent allocation method has not been modified.

User Response

Contact your product technical support for assistance.


CMUN01148E

The migration-related logical volume task cannot be initiated because the data state of the volume is not one of the two supported states for this task: Normal or Read only.

Explanation

When you attempt to pause, resume or cancel a logical volume migration, the volume must be in a supported data state when you submit the task.

User Response

Perform recovery procedures so that the rank, extent pool and storage image are in the correct state and functioning properly. Ensure that the logical volume that you select has a supported data state when you submit this task.


CMUN01149E

The migration task cannot be initiated at this time because the volume is in the process of an initialization.

Explanation

The volume initialization process occurs when a volume is created or expanded. This process prevents the initiation of the migration task because both tasks cannot access the logical volume concurrently.

User Response

Wait a few minutes, and resubmit the task.


CMUN01150E

The task cannot be initiated because a logical volume in the source extent pool that you have specified does not have a configuration state of Normal or Transposition Error.

Explanation

The Merge extent pools and Reconfigure extent pool tasks both require that all of the logical volumes in the source extent pool have a configuration state of Normal or Transposition Error.

User Response

Ensure that all of the logical volumes in the source extent pool have a configuration state of Normal or Transposition Error, and resubmit the task.


CMUN01151E

The task cannot be initiated because space-efficient storage in the source extent pool that you have specified does not have a configuration state of Normal or Transposition Error.

Explanation

The Merge extent pools and Reconfigure extent pool tasks both require that all of the space-efficient storage in the source extent pool have a configuration state of Normal or Transposition Error.

User Response

Ensure that all of the space-efficient storage in the source extent pool have a configuration state of Normal or Transposition Error, and resubmit the task.


CMUN01152E

The task cannot be initiated because the Easy Tier LIC feature key is not activated on the storage unit.

Explanation

To allow reconfiguration of an extent pool or merging of two extent pools, the Easy Tier LIC feature key must be installed and activated on the storage image.

User Response

Ensure that the Easy Tier LIC feature key is installed and activated on the storage image, and resubmit the task.


CMUN01153E

The merge extent pools task cannot be initiated because the source pool is in the process of migrating a volume or still contains a portion of a volume that is in a Migration Canceled state.

Explanation

You cannot reconfigure a source pool while a migration of one of its volumes is in progress or in a Migration Canceled state.

User Response

Before you resubmit the task, either allow the ongoing volume migration process to complete, reinitiate the canceled volume migration or delete the partially migrated volume.


CMUN01154E

The merge extent pools task cannot be initiated because ranks in the source pool are not valid.

Explanation

The ranks in the source pool must have a normal, reserved, or depopulation error configuration state, and the source pool must have a normal, read only, or degraded data state.

User Response

Before you resubmit the task, fix or delete the ranks in the source pool.


CMUN01155E

Unable to pause, resume, or cancel the logical volume migration possibly due to an ongoing task or operation.

Explanation

Another process or operation may be temporarily preventing the success of the command.

User Response

Wait 10 minutes and resubmit the command. If the command is still unsuccessful, contact your product technical support for assistance.


CMUN01156E

The storage image cannot be queried because the name of the control switch was not found during processing. Contact your product technical support for assistance.

Explanation

In the process of obtaining control switch values, a control switch name could not be found.

User Response

Contact your product technical support for assistance.


CMUN01157E

The storage image cannot be queried because the name of the control switch is not valid. Contact your product technical support for assistance.

Explanation

In the process of obtaining control switch values, an incorrect switch name was found.

User Response

Contact your product technical support for assistance.


CMUN01158E

The storage image cannot be queried because required information about the control switch cannot be found. Contact your product technical support for assistance.

Explanation

In the process of obtaining control switch values, control switch information could not be found.

User Response

Contact your product technical support for assistance.


CMUN01159E

The storage image cannot be queried because the control switch code is initializing the control switch.

Explanation

In the process of obtaining control switch values, the control switch was detected but support for the control switch is not currently available.

User Response

Wait 15 minutes before resubmitting the task.


CMUN01160E

The Create rank task cannot be initiated because the prerequisite completion of the initialize the drive configuration task cannot be determined.

Explanation

You cannot create a rank until the initialize drive configuration task has completed for all of the drives. The microcode for reliability, availability, and service determines whether or not the task has completed. An unexpected error prevents the determination as to whether this part of the microcode is loaded.

User Response

Contact your product technical support for assistance.


CMUN01161E

The Create rank task cannot be initiated because the initialize drive configuration task has not started.

Explanation

You cannot create a rank until the initialize drive configuration task has completed for all of the drives. This task is submitted by the microcode for reliability, availability, and service. This part of the microcode is not yet loaded.

User Response

Wait 5 minutes, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN01162E

The Create rank task has failed because the initialize drive configuration task has not completed.

Explanation

You cannot create a rank until the initialize drive configuration task has completed for all of the drives.

User Response

Wait 5 minutes, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02000E

Query failure: This action is supported only for CKD volumes.

Explanation

This action is supported only for count-key-data volumes.

User Response

Specify count-key-data volumes in a CKD logical subsystem, and then resubmit the task.


CMUN02001E

Error: The logical volume has been created, but it is not assigned to an address group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02002E

Error: The logical volume has been created but it is not assigned to a logical subsystem. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02003E

Error: The logical volume has been created, but it is not assigned to a volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02004E

Error: The logical volume has been created, but it is not assigned to an extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02005E

Unable to assign the rank to the extent pool. The rank is already assigned to another extent pool.

Explanation

You have selected to assign a previously assigned rank to the specified extent pool. You cannot assign ranks if they are assigned to other extent pools. You can assign a rank to only one extent pool.

User Response

Select a different rank to assign to the extent pool and resubmit the task.


CMUN02006E

Unable to query rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02007E

Unable to query rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02008E

Unable to query logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02009E

Unable to create array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02010E

Unable to create array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02011E

Unable to create array: internal interface communication error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02012E

Unable to create array: The array site is not unassigned.

Explanation

An array site is not in the unassigned state. The task requires an unassigned array site.

User Response

Check the status of the specified array site. Specify an unassigned array site, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02013E

The Create array task for the selected RAID type has failed because the subtask that identifies the array site for the RAID configuration has failed. There might be a serviceable event for a drive on the array site that you have selected, or the storage image might not be in dual-cluster mode. Contact your product technical support for assistance..

Explanation

The error might be reported due to one of the following three reasons.

  • The storage image is not in dual-cluster mode.
  • The array site has a drive in a bad state and therefore has an incorrect number of available drives.
  • The management console server reported a storage unit microcode-level logic error.

User Response

Contact your product technical support for assistance.


CMUN02014E

Cannot delete array. The array is flagged to be serviced.

Explanation

The array is flagged for service. An array in this state cannot be deleted until the service intent flag is removed.

User Response

Wait until service is completed on the array, and then resubmit the task.


CMUN02015E

The rank could not be deleted because it is assigned or depopulating.

Explanation

A rank cannot be deleted while it is in the Assigned or Depopulating state. The rank configuration states that are valid for the task include: Unassigned, Configuration Error, Configuring, Configuring Pending Error, Deconfiguring, Deconfiguring Error, and Configuration Pending.

User Response

Unassign the rank or if the rank is depopulating, wait 1-24 hours for completion, and resubmit the task.


CMUN02016E

Unable to delete logical subsystem: Logical volumes are assigned.

Explanation

Logical volumes are assigned to the logical subsystem. The logical subsystem cannot be deleted until these volumes are deleted.

User Response

Delete the logical volumes, and then resubmit the task.


CMUN02017E

Unable to delete rank: Extents are in use.

Explanation

The rank cannot be deleted because extents are still allocated from the rank.

User Response

Unallocate all storage from the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02018E

Unable to create or delete array: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02019E

Cannot exceed maximum volume group count

Explanation

The maximum volume group count has been reached. A new volume group cannot be created.

User Response

Remove unused volume groups, and then resubmit the task.


CMUN02020E

Unable to create logical subsystem: ID already in use.

Explanation

The logical subsystem cannot be created because the specified ID is already in use.

User Response

Specify a different logical subsystem ID, and then resubmit the task.


CMUN02021E

Unable to create logical volume: the volume number already exists.

Explanation

The specified logical volume exists already.

User Response

Specify a different volume number, and then resubmit the task.


CMUN02022E

Unable to create array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02023E

Unable to modify logical subsystem: cannot set session timeout

Explanation

The specified session timeout value is negative. Only positive values are valid.

User Response

Specify a valid timeout value, and then resubmit the task.


CMUN02024E

Unable to modify logical subsystem: incorrect critical mode enabled

Explanation

The specification contains an incorrect value for the critical mode enabled parameter.

User Response

Specify a valid value, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02025E

Unable to modify logical subsystem: incorrect extended long busy enabled parameter

Explanation

You specified an incorrect value for the extended long busy enabled parameter.

User Response

Specify a valid value, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02026E

Unable to modify logical subsystem: incorrect extended long busy time value

Explanation

The value that you specified for the extended long busy time parameter is negative. Only positive values are valid.

User Response

Specify a valid value, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02027E

Unable to modify logical subsystem: cannot set session timeout

Explanation

The specified session timeout value is negative. Only positive values are valid.

User Response

Specify a valid timeout value, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02028E

Cannot use array sites. These sites are flagged to be serviced.

Explanation

The array sites are flagged for service. An array cannot be created using these sites.

User Response

Wait until service is completed on the array sites, and then resubmit the task.


CMUN02029E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02030E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02031E

Operation failure: changes are pending

Explanation

The management console server reports a storage unit microcode-level error. The operation cannot be completed because previously stipulated changes have not yet been applied.

User Response

Ensure that any other tasks that you have initiated have been completed. Wait, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02032E

Unable to create logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02033E

Error: The logical volume has been deleted, but the logical subsystem deletion fails. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02034E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02035E

Unable to delete logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02036E

Unable to delete array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02037E

Unable to delete array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02038E

Unable to delete array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02039E

Unable to delete array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02040E

Unable to delete array. The array must be in an unassigned state.

Explanation

The array is still assigned. An assigned array cannot be deleted. Either ranks exist on the array, or a format operation is taking place. If you have already unassigned an array, it will enter an unavailable state, where it cannot be deleted, before it enters an unassigned state.

User Response

Delete the ranks on the array, wait for the array to become unassigned, or wait until the format completes, and then resubmit the task.


CMUN02041E

Unable to create logical subsystem: device type must be CKD

Explanation

The specified device type must be count-key-data.

User Response

Specify a CKD device type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02042E

Operation failure: configuration already exists

Explanation

You are attempting to create a configuration that already exists.

User Response

Specify a unique configuration, and then resubmit the task.


CMUN02043E

Operation failure: internal database not open. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02044E

Operation failure: unable to allocate memory. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02045E

Operation failure: unable to allocate memory. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02046E

Operation failure: unable to allocate memory. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02047E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02048E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02049E

Rank reconfiguration failure: memory allocation error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02050E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02051E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02052E

Storage unit unavailable

Explanation

An incorrect or unknown storage unit is specified.

User Response

Specify a valid and known storage unit.


CMUN02053E

Unable to create extent pool: maximum number of extent pools reached

Explanation

The maximum allowed number of extent pools in the storage image has been reached already.

User Response

Delete unused extent pools, and then resubmit the task.


CMUN02054E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02055E

Operation failure: unable to allocate memory

Explanation

The management console server reports a storage unit microcode-level error. The storage unit is unable to allocate memory. This might be a temporary problem that occurs during heavy usage.

User Response

Resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02056E

Operation failure: unable to allocate memory

Explanation

The management console server reports a storage unit microcode-level error. The storage unit is unable to allocate memory. This might be a temporary problem that occurs during heavy usage.

User Response

Resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02057E

Unable to assign rank to extent pool: The rank is not in the unassigned state.

Explanation

The rank must be in the unassigned state before it can be assigned. This error occurs most frequently when configuration of a rank has been initiated, but has not yet completed.

User Response

If the rank is in configuring state, wait until the rank status is changed to unassigned, and then resubmit the task. If the rank is in any other state, take the necessary steps to place it in the unassigned state, and then resubmit the task.


CMUN02058E

Unable to assign rank to extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02059E

Unable to assign rank to extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02060E

Unable to create extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02061E

Create logical subsystem failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02062E

Unable to modify SCSI host port: incorrect host type

Explanation

The host type is longer than the 16-character maximum length.

User Response

Specify a valid host type, and then resubmit the task.


CMUN02063E

Unable to create SCSI host port: incorrect WWPN

Explanation

The worldwide port name is not valid. A WWPN must be a 16-character hexadecimal string.

User Response

Specify a valid worldwide port name, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02064E

Unable to create SCSI host port: non-unique WWPN

Explanation

The worldwide port name is not unique.

User Response

Specify a unique worldwide port name, and then resubmit the task.


CMUN02065E

Operation failure: device adapter cannot query data

Explanation

The management console server reports a storage unit microcode-level error. This might be a temporary problem due to heavy traffic, or it might indicate a hardware failure.

User Response

Check for device adapter and storage device hardware errors, and follow the recommended service procedure. If the problem persists, contact your product technical support for assistance.


CMUN02066E

Operation failure: database creation error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. An internal database cannot be created.

User Response

Contact your product technical support for assistance.


CMUN02067E

Unable to create SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02068E

Unable to create SCSI host port: incorrect volume group identifier

Explanation

The specification contains an incorrect volume group identifier.

User Response

Specify a valid volume group identifier, and then resubmit the task.


CMUN02069E

Unable to create SCSI host port: incorrect profile

Explanation

The port profile length cannot be more than 16 characters.

User Response

Correct the port specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02070E

Unable to create SCSI host port: incorrect WWPN

Explanation

The worldwide port name is not valid. A WWPN must be a 16-character hexadecimal string.

User Response

Provide a valid worldwide port name, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02071E

Unable to create SCSI host port: incorrect WWPN

Explanation

The worldwide port name is not valid. A WWPN must be a 16-character hexadecimal string.

User Response

Provide a valid worldwide port name, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02072E

Unable to create SCSI host port: incorrect override default priority

Explanation

The attribute value that indicates whether default priority for I/O operations can be overridden is not valid.

User Response

Correct the port specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02073E

Unable to create volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02074E

Unable to create volume group: incorrect user name

Explanation

The specified user name is longer than the 16-character maximum length.

User Response

Specify a valid user name, and then resubmit the task.


CMUN02075E

Unable to delete extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02076E

Rank creation cannot complete. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02077E

Operation failure: addition. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02078E

Failed to initialize LPAR. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02079E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02080E

Unable to create array: The maximum number of arrays have been created.

Explanation

The array cannot be created because the maximum allowed number of arrays have been created already.

User Response

Add additional storage or delete one or more existing arrays, and then resubmit the task.


CMUN02081E

Unable to create rank: The maximum number of ranks has been created.

Explanation

The rank cannot be created because the maximum allowed number of ranks has already been created.

User Response

Add additional storage or delete one or more existing ranks, and then resubmit the task.


CMUN02082E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02083E

The extent availability query was unsuccessful because the specified extent pool ID is not valid.

Explanation

You have attempted to query an extent pool that was deleted, merged, or identified by an ID that does not exist.

User Response

Ensure that the extent pool ID is valid, and reissue the query.


CMUN02084E

Unable to delete extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02085E

Unable to delete extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02086E

Unable to delete logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02087E

Unable to query rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02088E

Unable to query rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02089E

Failed to initialize LPAR. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02090E

LPAR startup error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02091E

Failed to initialize LPAR. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02092E

Rank creation cannot complete. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02093E

The Create logical volume task has failed because the storage image is not in dual server mode or could not create a logical subsystem.

Explanation

The management console server reports a storage unit microcode-level error. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted, or the microcode could not create a logical subsystem before creating the logical volume.

User Response

Resubmit the task when both clusters are online. If both clusters are already online, or the problem persists, contact your product technical support for assistance.


CMUN02094E

Failed to initialize LPAR. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02095E

The create volume or create safeguarded backup capacity task cannot be initiated because the combination of capacity, volume type and data type that you have requested is not supported.

Explanation

The specification contains an incorrect combination of requested capacity, volume type, and data type. One of the two following conditions might have caused this error:

  • The requested capacity is less than the minimum capacity that is supported for the volume or safeguarded backup capacity type and data type.
  • The requested capacity is greater than the maximum capacity that is supported for the volume or safeguarded backup capacity type and data type.

User Response

Enter a supported combination of capacity, volume type and data type, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02096E

Unable to create logical volume

Explanation

The specification contains an incorrect combination of requested capacity, volume type, and data type.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02097E

Unable to query rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02098E

Unable to create logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02099E

Unable to create volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02100E

Volume group operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02101E

Unable to query volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02102E

Unable to delete logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02103E

Unable to assign volumes to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02104E

Unable to assign volume to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02105E

Unable to retrieve volumes assigned to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02106E

Unable to retrieve volumes assigned to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02107E

Unable to delete volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02108E

Unable to modify volume group

Explanation

This volume group is internally reserved and cannot be modified.

User Response

Specify a different volume group, and then resubmit the task.


CMUN02109E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02110E

Unable to modify SCSI host port: incorrect address discovery method

Explanation

You must specify how the port discovers the LUNs that are accessible by the host port. The host port can use one of two methods.

  • The Report LUNs command
  • LUN polling

User Response

Specify a valid address discovery method, and then resubmit the task.


CMUN02111E

Unable to modify SCSI host port: incorrect volume group type

Explanation

The volume group being assigned to the SCSI host port has an incorrect type.

User Response

Specify a volume group with a valid type, and then resubmit the task.


CMUN02112E

Unable to modify SCSI host port: incorrect volume group ID

Explanation

The specification contains an incorrect volume group identifier.

User Response

Specify a valid volume group identifier, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02113E

Unable to modify SCSI host port: logical block size and volume group type mismatch

Explanation

A 520-byte block size requires a SCSI520-All or SCSI520-Mask volume group type.

User Response

Specify a valid volume group type, and then resubmit the task.


CMUN02114E

Unable to modify SCSI host port: incorrect logical block size

Explanation

The logical block size of the devices that the port accesses must be either 512-bytes or 520-bytes.

User Response

Specify a valid logical block size, and then resubmit the task.


CMUN02115E

Unable to modify SCSI host port: logical block size and volume group type mismatch

Explanation

A 512-byte block size requires a SCSI-All, SCSI-Mask, or SCSI-Map 256 volume group type.

User Response

Specify compatible logical block size and volume group type, and then resubmit the task.


CMUN02116E

Unable to modify SCSI host port: incorrect port mask

Explanation

The management console server reports a storage unit microcode-level error. A mask that controls N-port logins contains an incorrect value.

User Response

Correct the port specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02117E

Unable to modify SCSI host port: incorrect override default priority value

Explanation

The attribute that indicates whether the default priority for I/O operations is to be overridden is not valid. The value must be either true or false.

User Response

Correct the port specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02118E

Unable to modify SCSI host port: incorrect port profile

Explanation

The port profile length cannot be more than 16 characters.

User Response

Correct the port specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02119E

Unable to modify SCSI host port: incorrect port topology

Explanation

The connecting port topology must be one of the following.

  • Unknown
  • Fibre Channel Point to Point or Switched (FCP)
  • Fibre Channel Arbitrated Loop (FC-AL)

User Response

Specify a valid connecting port topology, and then resubmit the task.


CMUN02120E

Unable to modify SCSI host port: address discovery method and volume group type mismatch

Explanation

The Report LUNs address discovery method requires a SCSI-Mask, SCSI-Map 256, or SCSI520-Mask volume group type.

User Response

Specify compatible address discovery method and volume group types, and then resubmit the task.


CMUN02121E

Unable to modify SCSI host port: address discovery method and volume group type mismatch

Explanation

The LUN Polling address discovery method requires a SCSI-All, SCSI-Map 256, SCSI520-All, or Copy Services volume group type.

User Response

Specify compatible address discovery method and volume group types, and then resubmit the task.


CMUN02122E

Unable to modify SCSI host port: incorrect value

Explanation

The management console server reports a storage unit microcode-level error. A mask that controls N-port logins contains an incorrect value.

User Response

Correct the port specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02123E

Unable to modify SCSI host port: nonexistent volume group

Explanation

The specified volume group does not exist.

User Response

Specify a valid volume group, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02124E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02125E

Unable to start or end service. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02126E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02127E

Unable to modify volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02128E

Unable to open a session to query a logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02129E

Unable to open a session. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02130E

Unable to open a session. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02131E

Internal database overwrite failure: The database exists and overwrite is off. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Database overwrite permission is turned off for an existing database. The database cannot be overwritten.

User Response

Contact your product technical support for assistance.


CMUN02132E

Rank creation cannot complete. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02133E

Extent pool operation failure

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Check for device adapter and storage device hardware errors, and follow the recommended service procedure. If the problem persists, contact your product technical support for assistance.


CMUN02134E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02135E

Volume group query failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02136E

Unable to query volume groups: incorrect volume number

Explanation

The specification contains an incorrect volume identifier. A logical volume identifier must be a 4-character hexadecimal string.

User Response

Specify a valid volume, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02137E

Unable to assign rank to extent pool: type mismatch

Explanation

The specified rank and extent pool must be the same type.

User Response

Specify the same type for rank and extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02138E

Unable to create rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02139E

Unable to create rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02140E

Unable to create rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02141E

The creation of the rank did not complete due to a device adapter failure.

Explanation

The creation of the rank did not complete successfully because of an error with a device adapter on the storage unit.

User Response

Check the operation of the device adapters and retry the operation. If the problem persists, contact your product technical support for assistance.


CMUN02142E

Rank creation did not complete. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02143E

Unable to create rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02144E

The rank could not be created because one or more drives are in the formatting, certifying, or failed state.

Explanation

One or more drives in the array site require repair or more time to complete the formatting or certifying process before the rank can be created.

User Response

Wait for the drives to complete a formatting or certifying process before resubmitting the task. If a drive is in the failed state, check the error log for drive-related entries and perform the recommended service action. If a rank creation error continues to occur, contact your product technical support for assistance.


CMUN02145E

Unable to create rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02146E

Rank creation failure: server unavailable. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02147E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The task must be invoked against a rank in the FAILED state. The rank is not in the FAILED state.

User Response

Contact your product technical support for assistance.


CMUN02148E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The task must be invoked against a rank in the inaccessible state. The rank is not in the inaccessible state.

User Response

Contact your product technical support for assistance.


CMUN02149E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The task must be invoked against a rank in the Repairing Formatted state. The rank is not in the Repairing Formatted state.

User Response

Contact your product technical support for assistance.


CMUN02150E

Unable to delete rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02151E

Unable to delete rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02152E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02153E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02154E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02155E

Rank operation failure: device adapter error

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Check for device adapter and storage device hardware errors, and follow the recommended service procedure. If the problem persists, contact your product technical support for assistance.


CMUN02156E

Unable to reconfigure rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02157E

Unable to reconfigure rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02158E

Unable to reconfigure rank: server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02159E

Rank reconfiguration failure: The rank is flagged to be serviced.

Explanation

The specified rank is flagged for service. A rank cannot be reconfigured while it is flagged for service.

User Response

Wait until the service is completed, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02160E

Unable to reconfigure rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02161E

Unable to release rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02162E

Unable to reserve rank. Verify that the ESE (Extent Space-efficient) repository size is appropriate. Verify that there are not any volumes or space-efficient storage in the pool.

Explanation

The ESE repository size, volumes, or space-efficient storage in the pool is preventing the rank from being reserved.

User Response

Modify the ESE repository size, remove volumes, or remove the space-efficient storage in the pool and then resubmit the task.


CMUN02163E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02164E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02165E

Unable to unassign rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02166E

Unable to reconfigure rank: The rank remains in the failed state. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02167E

Unable to release rank

Explanation

The rank is not reserved. Only reserved ranks can be released.

User Response

Reserve the rank or choose a reserved rank, and then resubmit the task.


CMUN02168E

Unable to assign volumes to volume group

Explanation

At least one of the volumes has an incorrect data type for the specified volume group.

  • A SCSI-Mask volume group requires a 512-byte block data type.
  • A SCSI520-Mask volume group requires a 520-byte block protected data type or a 520-byte block unprotected data type.

User Response

Specify volumes with compatible data types, and then resubmit the task.


CMUN02169E

Unable to assign volume to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02170E

Unable to assign volume to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02171E

Unable to assign volumes to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02172E

Unable to assign volume to volume group

Explanation

No rank has been created. At least one rank must exist before a volume can be created and assigned.

User Response

Create at least one rank and volume, and then resubmit the task.


CMUN02173E

Unable to assign volume to volume group: data type mismatch

Explanation

The data type of the volume does not match the data type of the volume group.

  • A SCSI-Mask volume group requires a 512-byte block data type.
  • A SCSI520-Mask volume group requires a 520-byte block protected data type or a 520-byte block unprotected data type.

User Response

Specify compatible data types, and then resubmit the task.


CMUN02174E

Unable to assign volume to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02175E

Unable to assign volume to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02176E

Unable to assign volume to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02177E

Unable to assign volume to volume group

Explanation

No rank has been created. At least one rank must exist before a volume can be created and assigned.

User Response

Create at least one rank and volume, and then resubmit the task.


CMUN02178E

Unable to reset Copy Services settings on logical subsystems. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02179E

Unable to reset Copy Services settings on logical subsystem. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02180E

Unable to reserve rank

Explanation

The rank is not assigned. Only assigned ranks can be reserved.

User Response

Assign the rank or choose an assigned rank, and then resubmit the task.


CMUN02181E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02182E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02183E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02184E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02185E

Unable to retrieve volumes assigned to the volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02186E

Unable to retrieve volumes assigned to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02187E

Unable to retrieve volumes assigned to the volume group: no ranks exist

Explanation

No ranks exist on the storage image. Volume information is not available.

User Response

Create at least one rank and volume on the storage image, and then resubmit the task.


CMUN02188E

Unable to retrieve volumes assigned to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02189E

Unable to retrieve volumes assigned to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02190E

Unable to assign volume to volume group

Explanation

No rank has been created. At least one rank must exist before a volume can be created and assigned.

User Response

Create at least one rank and volume, and then resubmit the task.


CMUN02191E

Unable to modify volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02192E

Unable to query rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02193E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02194E

Unable to create SCSI host port: incorrect port profile

Explanation

The port profile is not a supported port profile.

User Response

Specify a valid and supported port profile, and then resubmit the task.


CMUN02195E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02196E

SCSI host port operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02197E

Unable to modify SCSI host port: incorrect port profile

Explanation

The port profile is not a supported port profile.

User Response

Specify a valid and supported port profile, and then resubmit the task.


CMUN02198E

Unable to create, modify, or delete SCSI host port: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02199E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02200E

Unable to query volume groups. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02201E

Unable to assign volumes to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02202E

Unable to assign volumes to volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02203E

Unable to create, modify, or delete volume group: version update. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02204E

Volume group query failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02205E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02206E

Unable to unassign rank

Explanation

Only ranks in the reserved state can be unassigned. The rank is not in the reserved state.

User Response

Place the rank in the reserved state, or choose a reserved rank, and then resubmit the task.


CMUN02207E

Unable to unassign rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02208E

The rank cannot be unassigned because extents are allocated to logical volumes or space-efficient storage.

Explanation

Extents from the specified rank are allocated to logical volumes or space-efficient storage. The rank cannot be deleted while containing allocated storage. You must remove the volumes or space-efficient storage to deallocate the extents.

User Response

Deallocate all extents from the rank by removing any volumes or space-efficient storage that use the extents, and resubmit the task.


CMUN02209E

Unable to delete SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02210E

Unable to delete SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02211E

Unable to delete volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02212E

Unable to delete volume group: The volume group is still assigned to a SCSI host port.

Explanation

The volume group cannot be deleted because it is assigned to one or more host ports.

User Response

Unassign the volume group from the host ports, and then resubmit the task.


CMUN02213E

Unable to delete volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02214E

Unable to delete volume group

Explanation

The specified volume group is internally reserved and cannot be deleted.

User Response

Select another volume group, and resubmit the task.


CMUN02215E

Unable to retrieve volume group information. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02216E

Unable to modify volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02217E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02218E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02219E

Unable to create or delete volume group: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02220E

Unable to retrieve or assign volumes assigned to volume group: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02221E

Unable to retrieve or assign volumes assigned to volume group: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02222E

Operation failure. No ranks exist. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02223E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02224E

Unable to create volume group: incorrect volume group type

Explanation

The specified volume group type is not valid. The following volume group types are valid.

  • SCSI-Mask
  • SCSI-Map 256
  • SCSI520-Mask
  • Copy Services

User Response

Specify a valid volume group type, and then resubmit the task.


CMUN02225E

Unable to assign rank to extent pool. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02226E

Unable to end service: Management console is not authorized. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02227E

Unable to create logical volume: The data type of the logical volume is incompatible with the extent type of its extent pool.

Explanation

The data type of a logical volume must be compatible with the extent type of its extent pool.

User Response

Specify compatible types. Either specify a different data type for the logical volume, or specify a different extent pool. If the problem persists, contact your product technical support for assistance.


CMUN02228E

Rank creation cannot complete.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Check for device adapter and storage device hardware errors, and follow the recommended service procedure. If the problem persists, contact your product technical support for assistance.


CMUN02229E

Unable to create logical volume: Data type is incompatible with data type of other volumes in address group.

Explanation

The data type of the logical volume must be the same as the data type of other logical volumes in the address group.

User Response

Specify the same data type or a different address group, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02230E

Rank definition failure: extent type mismatch

Explanation

The extent types that are specified for the rank and its extent pool do not match.

User Response

Specify the same extent type for the rank and its extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02231E

Unable to create logical volume: rank group and logical subsystem group mismatch

Explanation

A logical volume is created from an extent pool in a rank group. The logical volume is also a member of a logical subsystem group. The rank group identifier and the logical subsystem group identifier must be identical.

User Response

Specify the same identifier for the rank group and the logical subsystem group. One way to do this is by specifying a different extent pool. If the problem persists, contact your product technical support for assistance.


CMUN02232E

Unable to create logical subsystem: device type mismatch

Explanation

The device type of the new logical subsystem is inconsistent with the device type of existing logical subsystems in the address group.

User Response

Specify consistent device types, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02233E

Logical volume operation failure: inconsistent starting and ending logical volume numbers

Explanation

The starting logical volume and the ending logical volume must belong to the same logical subsystem.

User Response

Specify the same logical subsystem for the starting and ending logical volumes, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02234E

Unable to create logical subsystem: device type format error

Explanation

The device type length must be less than 4 characters.

User Response

Specify a valid device type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02235E

Unable to create or modify logical subsystem: incorrect format

Explanation

A logical subsystem identifier must be 2 hexadecimal characters.

User Response

Specify a 2-hexadecimal character logical subsystem ID, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02236E

Unable to create or modify logical subsystem: incorrect format

Explanation

A logical subsystem identifier must be 2 hexadecimal characters.

User Response

Specify a 2 hexadecimal character logical subsystem ID, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02237E

Unable to create array: The RAID type is neither RAID5, RAID6 nor RAID10.

Explanation

The RAID type must be either RAID5, RAID6 or RAID10.

User Response

Specify a RAID5, RAID6 or RAID10 type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02238E

Unable to create or modify logical volume: incorrect number

Explanation

A logical volume number must be a 4-digit hexadecimal number.

User Response

Specify a 4-digit hexadecimal logical volume number, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02239E

Unable to create or modify logical volume: incorrect volume number

Explanation

A logical volume number must be a 4-digit hexadecimal number.

User Response

Specify a 4-digit hexadecimal logical volume number, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02240E

Unable to create logical volume: incorrect volume type

Explanation

The specification contains an incorrect volume type.

User Response

Specify a valid logical volume type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02241E

Service intent is not currently set. Reset ignored. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02242E

Unable to create rank: Array is not unassigned.

Explanation

The specification contains a reference to an assigned array. The rank must be created on an unassigned array.

User Response

Specify an unassigned array, and then resubmit the task.


CMUN02243E

Unable to create or modify logical subsystem

Explanation

The specification contains an incorrect CKD base control unit value.

User Response

Specify a valid value, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02244E

Logical volume operation failure: incorrect data type. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02245E

Unable to create extent pool: incorrect extent limit enabled value

Explanation

The specification contains an incorrect parameter value. The value for extent limit enabled is neither true nor false.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02246E

Unable to create extent pool: incorrect extent limit

Explanation

The specification contains an incorrect parameter value. The value for extent limit is not between 0 and 100.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02247E

Unable to create extent pool: incorrect extent threshold

Explanation

The specification contains an incorrect parameter value. The value for extent threshold is not between 0 and 100.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02248E

Unable to modify extent pool: incorrect extent threshold

Explanation

The specification contains an incorrect extent threshold value.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02249E

Unable to create extent pool: incorrect extent type

Explanation

The specification contains an incorrect extent type.

User Response

Specify a valid extent type, and then resubmit the task.


CMUN02250E

Unable to create or modify extent pool: incorrect user name

Explanation

The specification contains a user name that exceeds the 16-character limit.

User Response

Specify a valid user name, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02251E

Unable to modify extent pool: incorrect extent limit enabled value

Explanation

The specification contains an incorrect extent limit enabled value.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02252E

Unable to modify extent pool: incorrect extent limit

Explanation

The specification contains an incorrect extent limit value.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02253E

Unable to start or end service: incorrect management console ID. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02254E

Unable to create or modify logical volume: incorrect user name

Explanation

The specified user name is longer than the 16-character maximum length.

User Response

Specify a valid user name, and then resubmit the task.


CMUN02255E

Unable to create or modify logical subsystem: incorrect logical subsystem identifier format

Explanation

The logical subsystem identifier must be a 4-character hexadecimal number.

User Response

Specify a valid subsystem identifier, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02256E

Unable to create or modify logical subsystem: incorrect logical subsystem identifier length

Explanation

The subsystem identifier must be 4 characters long.

User Response

Specify a valid subsystem identifier, and then resubmit the task.


CMUN02257E

Logical subsystem query failure: incorrect LSS ID

Explanation

A logical subsystem ID is a hexadecimal value of the range (0 - FF).

User Response

Specify a valid identifier for the logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02258E

Unable to delete extent pool: ranks are assigned

Explanation

Ranks are assigned to the extent pool. The extent pool cannot be deleted while ranks are assigned to it.

User Response

Unassign the ranks, and then resubmit the task.


CMUN02259E

Unable to start or end service: incorrect parameters. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02260E

Operation failure: incorrect RAID type or number of spares. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02261E

Unable to create extent pool: incorrect rank group

Explanation

The specification contains an incorrect rank group.

User Response

Specify a valid rank group, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02262E

Unable to create volumes: incorrect volume type

Explanation

The specification contains an incorrect volume type. The following volume types are supported, but you might be limited to a subset of these by other factors in your storage definition.

CKD base.

  • 3380 cylinder
  • 3390 cylinder

CKD single-CU alia.

Fixed block base.

  • 512-byte block
  • 520-byte block unprotected
  • 520-byte block protected

User Response

Specify a valid volume type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02263E

Unable to create or delete extent pool: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02264E

Unable to end service: lock still held by other management console

Explanation

Service has been initiated by two management consoles. The other management console holds a lock.

User Response

Release the service intent lock from the other management console, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02265E

Logical volume operation failure: not supported

Explanation

The requested operation is not supported. This might be because the specified logical volume is an alias.

User Response

Specify a base logical volume, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02266E

Unable to modify logical subsystem: not a CKD volume

Explanation

The specification attributes a count-key-data value to a fixed block logical subsystem.

User Response

Change the specification or select a count-key-data logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02267E

Unable to create or modify logical subsystem: identifier already in use

Explanation

The specification contains a logical subsystem identifier that is already in use.

User Response

Specify a unique identifier for the logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02268E

Unable to create or modify logical subsystem: identifier must be nonzero

Explanation

The specification does not contain a logical subsystem identifier, or the identifier is zero. A nonzero identifier is required.

User Response

Specify a nonzero identifier for the logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02269E

Unable to modify logical subsystem: identifier only for CKD

Explanation

The specified subsystem identifier is reserved for count-key-data type logical subsystems. The specified logical subsystem is fixed block and cannot be modified in this manner.

User Response

Specify a CKD logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02270E

Unable to create a new SCSI host port: maximum count reached

Explanation

The maximum number of SCSI host ports has been created. No more SCSI host ports can be created.

User Response

Use an existing SCSI host port or delete an existing SCSI host port, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02271E

Unable to create SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02272E

SCSI host port operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02273E

Unable to modify SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02274E

Unable to delete SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02275E

Unable to create logical volume: volume type and data type mismatch

Explanation

The specification contains inconsistent volume type and data type information.

User Response

Specify consistent volume and data types, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02276E

Unable to delete rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02277E

Alias volume creation failure: no logical subsystem exists

Explanation

A logical subsystem must exist before multiple alias volumes can be created.

User Response

Create a logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02278E

Operation failure: name is not unique

Explanation

The specification contains a name that is already being used.

User Response

Specify a unique name, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02279E

Operation failure: unknown storage unit

Explanation

The specification contains a reference to an unknown storage unit.

User Response

Specify a valid storage unit, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02280E

Unable to assign rank to extent pool: The extent pool does not exist.

Explanation

The specification contains an incorrect reference to an extent pool.

User Response

Specify a valid extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02281E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02282E

Unable to create CKD logical volume: CKD volumes require a CKD logical subsystem.

Explanation

You must create a count-key-data type logical subsystem before you can create count-key-data type volumes.

User Response

Create a CKD logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02283E

Unable to create CKD alias logical volume: no base volume exists.

Explanation

The specification contains a reference to a nonexistent base volume. A count-key-data alias can be created for existing base volumes only.

User Response

Specify a valid base volume that is contained within the same logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02284E

Logical subsystem operation failure: logical subsystem does not exist.

Explanation

The specification contains a reference to a nonexistent logical subsystem.

User Response

Specify an existing logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02285E

Unable to create rank: array does not exist.

Explanation

The specification contains a reference to a nonexistent array.

User Response

Specify an existing array, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02286E

Rank operation failure: extent pool does not exist.

Explanation

The specification contains a reference to a nonexistent extent pool.

User Response

Specify an existing extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02287E

Rank operation failure: rank does not exist.

Explanation

The specification contains a reference to a nonexistent rank.

User Response

Specify an existing rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02288E

Rank operation failure: rank does not exist.

Explanation

The specification contains a reference to a nonexistent rank.

User Response

Specify an existing rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02289E

Rank operation failure: rank does not exist.

Explanation

The specification contains a reference to a nonexistent rank.

User Response

Specify an existing rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02290E

Unable to create logical volume: extent pool does not exist.

Explanation

The specification contains a reference to a nonexistent extent pool.

User Response

Specify an existing extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02291E

Unable to start service: device adapter pair is configuring.

Explanation

Service intent cannot be set while a device on the adapter pair is still configuring.

User Response

Wait until the device configuration completes, and then resubmit the task.


CMUN02292E

XML parse error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. An XML file cannot be parsed.

User Response

Contact your product technical support for assistance.


CMUN02293E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02294E

Unable to delete logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02295E

Unable to delete logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02296E

Unable to delete logical volume.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Resubmit the deletion task. If the problem persists, contact your product technical support for assistance.


CMUN02297E

Unable to create logical volume: FB volumes must have a data type.

Explanation

The specification for a fixed block logical volume does not contain a data type. Fixed block logical volumes must have one of the following data types.

  • 512-byte block
  • 520-byte block unprotected
  • 520-byte block protected

User Response

Specify a data type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02298E

Unable to create logical volume: FB volumes must have an extent pool.

Explanation

The logical volume specification does not contain an extent pool. Fixed block logical volumes must have an extent pool from which their extents are allocated.

User Response

Specify an extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02299E

Unable to create logical volume: FB volumes must have a requested capacity.

Explanation

The logical volume specification does not contain a requested capacity.

User Response

Specify a requested capacity, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02300E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02301E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02302E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02303E

Rank operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02304E

Unable to create array: memory allocation error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02305E

Operation failure: SCSI host port already exists.

Explanation

The specified SCSI host port already exists.

User Response

Specify a new SCSI host port, and then resubmit the task.


CMUN02306E

Unable to create, modify, or delete logical volume: service intent is set on extent pool.

Explanation

The extent pool is flagged to be serviced. No operations can be performed on extent pool objects while it is flagged for service.

User Response

Wait until service is completed on the extent pool, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02307E

Unable to create logical volume

Explanation

The specification contains an incorrect combination of requested capacity, volume type, and data type.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02308E

Query failure: logical subsystem does not exist.

Explanation

The specification contains a reference to a nonexistent logical subsystem.

User Response

Specify an existing logical subsystem, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02309E

Unable to modify logical volume: volume type and data type mismatch

Explanation

A fixed block type logical volume must have a fixed block data type. A count-key-data type logical volume must have a count-key-data data type.

User Response

Specify a valid data type for the logical volume, and then resubmit the task.


CMUN02310E

Unable to add logical volume to the logical subsystem (LSS).

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Ensure that the LSS is correct and that it does not already contain the maximum number of logical volumes. If the problem persists, contact your product technical support for assistance.


CMUN02311E

Unable to create logical subsystem. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02312E

Unable to delete logical subsystem. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02313E

Unable to delete logical subsystem. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02314E

Unable to modify logical volume. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02315E

Unable to modify logical subsystem. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02316E

Logical subsystem query failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02317E

Unable to delete CKD base logical volume: alias assigned

Explanation

At least one alias is assigned to the count-key-data base logical volume. Aliases must be deleted before the count-key-data base logical volume can be deleted.

User Response

Remove the aliases, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02318E

Unable to create rank: Too many arrays are specified.

Explanation

The management console server reports a storage unit microcode-level error. Only one array can be specified.

User Response

Specify one array, and then resubmit the task.


CMUN02319E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02320E

Unable to create rank: Service intent is set on the array.

Explanation

An array that is required for the operation has been flagged to be serviced. The array cannot be used while the service flag is set.

User Response

Wait until service is completed on the array, and then resubmit the task.


CMUN02321E

Unable to repair array: Service intent is set.

Explanation

The array has been flagged to be serviced. The array cannot be used while the service flag is set.

User Response

Wait until service is completed on the array, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02322E

Unable to repair array: Service intent is set.

Explanation

The array has been flagged to be serviced. The array cannot be used while the service flag is set.

User Response

Wait until service is completed on the array, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02323E

Unable to assign rank to extent pool: Service intent is set on the storage complex.

Explanation

The storage complex has been flagged to be serviced. No activities can be performed on objects in the storage complex while the service flag is set.

User Response

Wait until service is completed on the storage complex, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02324E

Unable to assign rank to extent pool: Service intent is set.

Explanation

The rank has been flagged to be serviced. No activities can be performed on the rank while the service flag is set.

User Response

Wait until service is completed on the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02325E

Unable to create rank: not in dual server mode

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02326E

Unable to release rank: Service intent is set.

Explanation

The rank has been flagged to be serviced. No activities can be performed on the rank while the service flag is set.

User Response

Wait until service is completed on the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02327E

Unable to reserve rank: Service intent is set.

Explanation

The rank has been flagged to be serviced. No activities can be performed on the rank while the service flag is set.

User Response

Wait until service is completed on the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02328E

Unable to unassign rank: Service intent is set.

Explanation

The rank has been flagged to be serviced. No activities can be performed on the rank while the service flag is set.

User Response

Wait until service is completed on the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02329E

Unable to delete rank: not in dual server mode

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02330E

Unable to repair array: Service intent is set.

Explanation

The array has been flagged to be serviced. No activities can be performed on the array while the service flag is set.

User Response

Wait until service is completed on the array, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02331E

Unable to delete rank

Explanation

The management console server reports a storage unit device adapter error.

User Response

Contact your product technical support for assistance.


CMUN02332E

Unable to delete rank. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit device adapter error.

User Response

Contact your product technical support for assistance.


CMUN02333E

Unable to delete rank: Service intent is set.

Explanation

The rank has been flagged to be serviced. No activities can be performed on the rank while the service flag is set.

User Response

Wait until service is completed on the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02334E

Unable to unfence volume through rank: Service intent is set.

Explanation

The rank has been flagged to be serviced. No activities can be performed on the rank or volumes within the rank while the service flag is set.

User Response

Wait until service is completed on the rank, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02335E

Unable to create volumes: volume type must be specified

Explanation

No volume type has been specified for the volumes. The following volume types are supported, but you might be limited to a subset of these by other factors in your storage definition.

CKD base.

  • 3380 cylinder
  • 3390 cylinder

CKD single-CU alia.

Fixed block base.

  • 512-byte block
  • 520-byte block unprotected
  • 520-byte block protected

User Response

Specify a valid volume type, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02336E

Unable to rebuild array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02337E

Unable to create or modify logical volume: CKD base logical volume does not exist.

Explanation

The specified logical volume does not exist or it is not a count-key-data base volume.

User Response

Create the base logical volume or specify a different base logical volume, and then resubmit the task.


CMUN02338E

Delete SCSI host port operation stopped. Previous attempt failed. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. A list of SCSI host ports is specified to be deleted. Because a previous deletion failed, successive deletions in the list have stopped.

User Response

Contact your product technical support for assistance.


CMUN02339E

Delete volume group operation stopped. Previous attempt failed. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. A list of volume groups are specified to be deleted. Because a previous deletion failed, successive deletions in the list have stopped.

User Response

Contact your product technical support for assistance.


CMUN02340E

Array site operation failure: The array site is used in another array.

Explanation

The specified array site is used in other array.

User Response

Specify an unused array site, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02341E

Logical subsystem configuration error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02342E

Unable to delete last global data rank. Logical subsystem or logical control unit exists.

Explanation

The last global data rank cannot be deleted because one or more logical subsystems or logical control units (LCUs) still exist.

User Response

Delete all logical subsystems and logical control units, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02343E

Unable to create logical subsystem: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02344E

Unable to delete logical subsystem: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02345E

Unable to create logical volume: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02346E

Unable to create logical volume: logical subsystem not in correct state. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. The logical volume cannot be created because its logical subsystem is not in the correct state.

User Response

Contact your product technical support for assistance.


CMUN02347E

Unable to delete logical volume: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02348E

Operation failure: logical subsystem not in correct state. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02349E

The logical volume cannot be modified because it is in a state that is other than normal.

Explanation

A volume can only be modified if it is in a normal state.

User Response

If the volume state is:

  • migrating, await completion, and resubmit the task.
  • migration paused, resume migration, await completion, and resubmit the task.
  • migration canceled or error, remigrate back to the source or target pool, await completion, and resubmit the task.
  • reconfiguring, await completion of volume expansion, and resubmit the task.

If the volume is in a different error state, contact your product technical support for assistance.


CMUN02350E

Logical volume operation failure: incorrect state. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02351E

Logical volume operation failure: Base volume is in incorrect state.

Explanation

The logical volume operation fails because its base logical volume is not in the correct state.

User Response

Change the configuration state of the base logical volume, or wait until its configuration completes, and then resubmit the task.


CMUN02352E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02353E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02354E

Operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02355E

Unable to delete SCSI host port. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02356E

Unable to create SCSI host port: incorrect user host description

Explanation

The SCSI host port specification contains an incorrect user host description. The SCSI host port cannot be created.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02357E

Unable to create SCSI host port: incorrect user host name

Explanation

The SCSI host port specification contains an incorrect user host name. The SCSI host port cannot be created.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02358E

Unable to modify SCSI host port: incorrect user host description

Explanation

The SCSI host port specification contains an incorrect user host description. The SCSI host port cannot be modified.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02359E

Unable to modify SCSI host port: incorrect user host name

Explanation

The SCSI host port specification contains an incorrect user host name. The SCSI host port cannot be modified.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02360E

Unable to add logical volume to volume group: incorrect parameter

Explanation

The operation to add the logical volume to the volume group fails because an incorrect parameter is detected.

User Response

Correct the specification, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02361E

Unable to modify volume group: incorrect user name

Explanation

The volume group cannot be modified because the user name that is provided is not valid.

User Response

Use a valid user name with appropriate permissions, and then resubmit the task.


CMUN02362E

Unable to query volume groups: incorrect volume configuration. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02363E

Unable to query volume groups: incorrect parameter. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02364E

Unable to query volume groups: volume does not exist. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02365E

Unable to remove logical volume from volume group: incorrect parameter. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02366E

Volume group operation failure: local server offline

Explanation

The management console server reports a storage unit microcode-level error. A local server is not online. Microcode initialization might not have completed, or a failover has occurred and one server has not yet restarted.

User Response

Monitor system status, and resubmit the task when both servers are online. If the problem persists, contact your product technical support for assistance.


CMUN02367E

Volume group operation failure: incorrect volume configuration. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02368E

Volume group operation failure: volume does not exist. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02369E

Volume group operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02370E

Volume group operation failure: incorrect volume configuration. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02371E

Volume group operation failure: incorrect parameter. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02372E

Volume group operation failure: volume does not exist.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Ensure that each volume that you specify exists, and resubmit the task.


CMUN02373E

Volume group operation failure: incorrect parameter. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02374E

Unable to delete volume group. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02375E

Volume group operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02376E

The logical volume cannot be modified because of an incorrect data type selection.

Explanation

Data type selections are restricted and some data type changes are not allowed. For instance, you cannot change the data type for System i volumes.

User Response

Specify a correct data type, and resubmit the task.


CMUN02377E

Error: inconsistent alias and base logical volume numbers

Explanation

The first two digits of an alias logical volume number and its base logical volume number must be identical.

User Response

Specify consistent alias and base logical volume numbers, and then resubmit the task.


CMUN02378E

Error: A volume of this type cannot have an alias volume group.

Explanation

An alias volume group is specified for a volume type that does not support the specification of aliases.

User Response

Correct the specification, and then resubmit the task.


CMUN02379E

Error: A volume of this type cannot have a base logical volume number.

Explanation

A base logical volume number is specified for a volume type that does not support the specification of base logical volumes.

User Response

Correct the specification, and then resubmit the task.


CMUN02380E

Unable to create array. Array sites must be in the same loop.

Explanation

Array creation across loops is not supported. The specified array sites are not in the same loop, and an array cannot be created using these array sites.

User Response

Specify arrays that are in the same loop, and then resubmit the task.


CMUN02381E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02382E

Unable to repair array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02383E

Unable to create, delete, or modify logical subsystem resources. The resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02384E

Operation failure: incorrect file type. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. A configuration file is not the correct file type.

User Response

Contact your product technical support for assistance.


CMUN02385E

Unable to modify network port: The specified IP address is not valid. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. An incorrect IP address is specified.

User Response

Contact your product technical support for assistance.


CMUN02386E

Unable to modify network port: The specified network is not valid. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. An incorrect network is specified.

User Response

Contact your product technical support for assistance.


CMUN02389E

Unable to create volume. Not enough extents are available.

Explanation

The volume cannot be created because not enough extents are available in the extent pool. More extents must be added to the extent pool.

User Response

Add more extents to the extent pool, and then resubmit the task.


CMUN02390E

The Create volume task has failed. Extents are currently being formatted and will be available at a later time.

Explanation

The Create volume task did not complete because there are too few available extents. However, recently released extents are being reformatted. A sufficient number of extents will be available when the reformatting process completes. One terabyte of disk space can be reformatted in approximately four hours.

User Response

Wait until a sufficient amount of extents have been reformatted to create the volume, and resubmit the task.


CMUN02391E

Unable to delete CKD base volume. Unable to delete or reassign aliases.

Explanation

The management console server reports a storage unit microcode-level error. The CKD base volume cannot be deleted because its alias volumes cannot be deleted or reassigned.

User Response

Delete or reassign the alias volumes first, and then resubmit the task.


CMUN02392E

Incorrect alias volume group

Explanation

The specified alias volume group does not exist or is not a FICON/ESCON - MASK type volume group. Volume group 10 is the default valid volume group of this type.

User Response

Specify a valid volume group, and then resubmit the task.


CMUN02393E

Unable to create or modify CKD alias volume. The base and alias volumes belong to different logical subsystems.

Explanation

The base and its alias volumes must belong to the same logical subsystem.

User Response

Specify base and alias volumes that belong to the same logical subsystem, and then resubmit the task.


CMUN02394E

Unable to create or modify CKD alias volume. The maximum number of aliases is already assigned to the base volume.

Explanation

A maximum of 255 aliases can be assigned to a base volume. The specified base volume already has 255 aliases that are assigned to it.

User Response

Specify a different base volume, or reassign some of the previously assigned alias volumes, and then resubmit the task.


CMUN02395E

Unable to create or modify CKD alias volume. The base volume and alias volume are not in the same volume group.

Explanation

The base volume and alias volume must be in the same volume group. To create a new alias volume in the volume group, assign the base volume to the volume group, and then create the alias volume in the volume group. To modify an existing alias volume, you must select a base volume that is already in that volume group.

User Response

Specify a base volume and alias volume that are in the same volume group and then resubmit the task.


CMUN02396E

You must enter contact information before you can invoke the Call Home function.

Explanation

You must enter your company name, building location, ship to country information, and primary contact telephone number before you can invoke the Call Home function.

User Response

Use the command-line interface setcontactinfo command to enter contact information, and then resubmit the task.


CMUN02397E

Unable to delete volume: The volume does not exist.

Explanation

The specified volume cannot be found. Therefore, it cannot be deleted.

User Response

Specify a different volume to delete.


CMUN02400E

Unable to create logical subsystem: incorrect address group

Explanation

The specification contains an incorrect address group.

User Response

Specify a valid address group, and then resubmit the task.


CMUN02401E

Unable to create logical subsystem: microcode-level error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02406E

Internal logical configuration error: Collect a PE package.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Collect a PE package and contact your product technical support for assistance.


CMUN02407E

Array operation failure: The resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02408E

Array creation failure: Too many array sites specified.

Explanation

You must specify only one array site when creating RAID5, RAID6 or RAID10 arrays. Multiple array sites are specified.

User Response

Specify only one array site, and then resubmit the task.


CMUN02409E

Rank operation failure: The resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02410E

Extent pool operation failure: The resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02411E

Logical volume operation failure: The resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02412E

Volume group operation failure: The host agent resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02413E

SCSI host port operation failure: The host agent resource manager is unavailable on an alternate server.

Explanation

The management console server has reported a storage unit microcode-level error. This error can be caused by a temporary condition on the storage facility.

User Response

Wait 10 minutes and retry the operation. If the operation is still unsuccessful, contact your product technical support for assistance.


CMUN02414E

Unable to create SCSI host port. A colon : cannot be used when specifying a SCSI host port.

Explanation

A colon : is used in a SCSI host port specification. This character cannot be used in a SCSI host port specification.

User Response

Omit the colon, and then resubmit the task.


CMUN02415E

Unable to modify SCSI host port. A colon : cannot be used when specifying a SCSI host port.

Explanation

A colon : is used in a SCSI host port specification. This character cannot be used in a SCSI host port specification.

User Response

Omit the colon, and then resubmit the task.


CMUN02416E

Rank repair operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02417E

Rank repair operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02418E

Rank repair operation failure: At least one array must be in assigned status. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02419E

Rank repair operation failure: Service intent flag is set. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02420E

Rank repair operation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02421E

Rank repair operation failure: Unable to establish array site communication session. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02422E

Rank repair operation failure: Unable to retrieve adapter name. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02423E

Rank repair operation failure: device adapter error. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02424E

Rank repair operation failure: Multiple ranks exist or the rank is still accessible. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02425E

Rank repair operation failure: Unable to delete RAID array. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02426E

Rank repair operation failure: Unable to retrieve serial number. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02427E

Internal logical configuration error: Another configuration is in progress.

Explanation

The management console server reports a storage unit microcode-level error. Another configuration process is in progress. Your task cannot be performed at this time.

User Response

Wait, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02429E

A recovery is in progress. Logical configuration commands are blocked.

Explanation

A recovery is in progress. Logical configurations commands are rejected until recovery completes.

User Response

Wait, and then resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02430E

Incorrect configuration: The base and alias/map volumes must be in the same volume group.

Explanation

A volume group cannot contain an alias/map volume unless the base volume is also in that group.

User Response

Ensure that the base and alias/map volumes are in the same volume group, and then resubmit the task.


CMUN02431E

Incorrect configuration: A volume group cannot contain unconfigured logical volumes.

Explanation

A volume group cannot contain an unconfigured volume. One or more of the specified volumes is not in the configured state.

User Response

Specify only configured volumes, and then resubmit the task.


CMUN02432E

Incorrect configuration: volume group and volume type mismatch

Explanation

A FICON ESCON mixed volume group can contain only logical volumes of the following types.

  • count-key-data base
  • count-key-data alias
  • count-key-data map
  • 512-byte fixed-block

User Response

Specify logical volumes of the correct type, and then resubmit the task.


CMUN02433E

Incorrect configuration: 512-byte fixed-block volumes must share data.

Explanation

In a FICON ESCON mixed volume group, all logical volumes of type 512-byte fixed-block must have data sharing allowed set to true.

User Response

Ensure that all 512-byte fixed-block volumes permit data sharing, and then resubmit the task.


CMUN02434E

Incorrect configuration: volume group and volume type mismatch

Explanation

A FICON ESCON (not mixed) volume group can contain only logical volumes of the following types: count-key-data base or count-key-data alias.

User Response

Specify only count-key-data base or count-key-data alias volumes, and then resubmit the task.


CMUN02435E

Incorrect configuration: volume group and volume type mismatch

Explanation

A SCSI (not mixed) volume group must contain only logical volumes of type 512-byte fixed-block.

User Response

Specify only 512-byte fixed-block logical volumes, and then resubmit the task.


CMUN02436E

Incorrect configuration: volume group and volume type mismatch

Explanation

A SCSI mixed volume group must contain only logical volumes of the following types.

  • fixed-block map
  • count-key-data base
  • 520-byte fixed-block

User Response

Specify only volumes of types fixed-block map, count-key-data base, or 520-byte fixed-block base. Then resubmit the task.


CMUN02437E

Incorrect configuration: CKD base logical volumes must share data.

Explanation

In a SCSI mixed volume group, all count-key-data base logical volumes must have data sharing allowed set to true.

User Response

Ensure that all count-key-data base logical volumes permit data sharing, and then resubmit the task.


CMUN02438E

Incorrect configuration: volume group and volume type mismatch

Explanation

A SCSI520 MASK volume group must contain only logical volumes of type 520-byte fixed block.

User Response

Specify only 520-byte fixed block logical volumes, and then resubmit the task.


CMUN02442E

Unable to create volume.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Collect a PE package and contact your product technical support for assistance.


CMUN02443E

Unable to create volume.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Collect a PE package and contact your product technical support for assistance.


CMUN02448E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02449E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02450E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02451E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02452E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02453E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02454E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02455E

Feature install activation failure: Unable to decrypt license key.

Explanation

The license key that you provided cannot be decrypted correctly.

User Response

If you entered the key incorrectly, enter the key correctly and resubmit the task. If this does not resolve the problem, contact your product technical support for assistance.


CMUN02456E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02457E

Feature install activation failure. Contact your product technical support for assistance.

Explanation

The management console server reports a storage unit microcode-level error. Installation of a license machine code feature fails.

User Response

Contact your product technical support for assistance.


CMUN02458E

Feature key validation failure: key type does not match storage type

Explanation

The license machine code feature key validation fails. Either the key type is not valid, or the key type does not match the storage type (FB/CKD/BOTH).

User Response

Ensure that the license key matches the storage type. If this does not resolve the problem, contact your product technical support for assistance.


CMUN02459E

Unable to modify network port. The IP addresses of the two clusters cannot be identical.

Explanation

The same IP address is specified for both clusters. Unique IP addresses must be assigned.

User Response

Specify unique IP addresses, and then resubmit the task.


CMUN02460E

Unable to modify network port. Retry.

Explanation

The management console server reports a storage unit microcode-level error. The network port modification process did not fully complete.

User Response

This might be a temporary problem. Resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02461E

LIC feature build key failed. Contact your product technical support for assistance.

Explanation

The requested LIC feature activation failed because the LIC feature build encryption key failed.

User Response

Contact your product technical support for assistance.


CMUN02462E

Incorrect storage image sequence number in the LIC feature key.

Explanation

The sequence number in the LIC feature key is not valid for the storage image.

User Response

Verify that you have entered the correct LIC feature key for the storage image. If the LIC feature key that you originally entered was not correct, resubmit the task with the correct LIC feature key. If you originally entered the correct key, contact your product technical support for assistance.


CMUN02463E

Creation of LIC feature file failed. Contact your product technical support for assistance.

Explanation

The creation of the LIC feature file failed.

User Response

Contact your product technical support for assistance.


CMUN02464E

Error decrypting LIC feature string or file. Contact your product technical support for assistance.

Explanation

The LIC feature string or file cannot be decrypted.

User Response

Contact your product technical support for assistance.


CMUN02465E

Error encrypting LIC feature string or file. Contact your product technical support for assistance.

Explanation

The LIC feature string or file cannot be encrypted.

User Response

Contact your product technical support for assistance.


CMUN02466E

LIC feature string validation failed. Contact your product technical support for assistance.

Explanation

The LIC feature string cannot be validated.

User Response

Contact your product technical support for assistance.


CMUN02467E

Incorrect LIC feature type.

Explanation

You either entered a LIC feature key for a LIC feature type that is not yet supported or you entered an incorrect LIC feature key.

User Response

Verify that you entered the correct LIC feature key and that the feature type is valid. If either the LIC feature key or feature type is not valid, resubmit the task with a valid feature key or feature type. If the problem persists, contact your product technical support for assistance.


CMUN02468E

Error opening LIC feature file. Contact your product technical support for assistance.

Explanation

The LIC feature file cannot be opened.

User Response

Contact your product technical support for assistance.


CMUN02469E

Error writing to the LIC feature file. Contact your product technical support for assistance.

Explanation

The LIC feature file cannot be written.

User Response

Contact your product technical support for assistance.


CMUN02470E

LIC feature file validation failed. Contact your product technical support for assistance.

Explanation

The LIC feature file validation failed.

User Response

Contact your product technical support for assistance.


CMUN02471E

Error activating LIC feature file. Contact your product technical support for assistance.

Explanation

The LIC feature file cannot be activated.

User Response

Contact your product technical support for assistance.


CMUN02472E

Error displaying LIC feature information. Contact your product technical support for assistance.

Explanation

The LIC feature information cannot be displayed.

User Response

Contact your product technical support for assistance.


CMUN02473E

Error querying LIC feature information. Contact your product technical support for assistance.

Explanation

The LIC feature information cannot be queried.

User Response

Contact your product technical support for assistance.


CMUN02474E

Error determining product information to be used for LIC features. Contact your product technical support for assistance.

Explanation

The product information that is necessary for LIC features cannot be determined.

User Response

Contact your product technical support for assistance.


CMUN02475E

LIC feature storage type is not correct.

Explanation

You have selected an incorrect LIC feature storage type. Some LIC feature types require a specific storage type (FB, CKD, or combined) and cannot be activated with the incorrect storage type. For example, the remote mirror feature for z/OS and parallel access volumes (PAVs) require that you select the CKD storage type. You can select one of the following storage types:

  • Fixed block (FB): Select this storage type if you are connecting only to open systems hosts.
  • Count key data (CKD): Select this storage type if you are connecting only to System z hosts.
  • All (FB and CKD): Select this storage type if you are connecting both open systems and System z hosts.

User Response

Select the appropriate LIC feature storage type and resubmit the task with the appropriate LIC feature key.


CMUN02476E

Incorrect LIC feature key length.

Explanation

The LIC feature key length is not valid.

User Response

Enter the correct LIC feature key, and resubmit the task.


CMUN02477E

Licensed function activation is disabled. Contact your product technical support for assistance.

Explanation

You are attempting to activate a licensed function but the task is not currently allowed.

User Response

Contact your product technical support for assistance.


CMUN02478E

LIC feature cannot be installed due to the maximum number of logical subsystems for CKD storage. Contact your product technical support for assistance.

Explanation

You cannot install the LIC feature because it will exceed the maximum number of allowed logical subsystems for CKD-type storage.

User Response

Contact your product technical support for assistance.


CMUN02479E

The volume group modification or creation task failed. You have specified a volume that does not exist.

Explanation

You have specified a volume group configuration that contains one or more volumes that do not exist or has not yet been created. All specified volumes must exist before you can add them to the volume group.

User Response

Remove the nonexistent volumes from the volume group configuration, and resubmit the task.


CMUN02480E

LIC feature capacity error. Incorrect capacity value for the specified LIC feature type.

Explanation

The LIC feature capacity value that you have selected for the LIC feature key is not valid for this LIC feature type.

User Response

Select a valid capacity to obtain a new LIC feature key and resubmit the task.


CMUN02481E

The modify host adapter port task failed because the host adapter port is not defined.

Explanation

You have specified a host adapter port for modification that is not defined. This failure can be the result of one of the following causes.

  • A transient timing issue during the dynamic update of the logical host port adapter definition
  • A host port adapter hardware problem
  • A cable problem
  • A discrepancy between the physical host port adapter configuration and the logical host port adapter configuration

User Response

Perform each of the following steps to resolve the issue:

  • Correct any hardware errors.
  • Ensure that all cables are connected and seated correctly.
  • Verify that the physical host adapter port configuration matches the displayed logical host port adapter configuration.

If the problem still persists, contact your product technical support for assistance.


CMUN02482E

The modify host adapter port task failed because the host adapter port cannot be modified unless both processor cards show normal status.

Explanation

You are attempting to modify a host adapter port while at least one of the processor cards is unavailable. The modify host port adapter task requires that both processor cards in the storage unit are working together.

User Response

Correct any hardware errors. Ensure that both processor cards show normal status. If the problem persists, contact your product technical support for assistance.


CMUN02483E

The modify host adapter port task failed because the port failed to change to the offline or online state.

Explanation

The modify host adapter port task must take the port offline before the modification is made and take the port online after changing the port type. The utility that takes the port offline and online has failed.

User Response

Verify that the storage unit status is normal. If the problem persists, contact your product technical support for assistance.


CMUN02484E

The modify host adapter port task failed because the host adapter port type modification failed.

Explanation

You are attempting to modify the host port type to an incorrect value or to modify the host port type while the storage unit is unavailable. The utility that changes the host adapter port type has failed.

User Response

Verify that the storage unit status is normal. If the problem persists, contact your product technical support for assistance.


CMUN02488E

Internal error. Contact your product technical support for assistance.

Explanation

The management console reports a storage unit microcode-level error. The rank failed to change to an offline state.

User Response

Contact your product technical support for assistance.


CMUN02489E

Internal error. Contact your product technical support for assistance.

Explanation

The management console reports a storage unit microcode-level error. The rank failed to change to a failed state.

User Response

Contact your product technical support for assistance.


CMUN02490E

Internal error. Contact your product technical support for assistance.

Explanation

The management console reports a storage unit microcode-level error. The previously used array was not deleted.

User Response

Contact your product technical support for assistance.


CMUN02491E

The extent pool cannot be deleted. Logical volumes are still assigned to the extent pool.

Explanation

There are volumes that are currently associated with the extent pool that you are attempting to delete.

User Response

Remove the logical volumes that are assigned to the specified extent pool, and resubmit the task.


CMUN02492E

Unable to create the SCSI host port. Another SCSI host port exists with the same worldwide port name and a conflicting port ID.

Explanation

You have attempted to create a SCSI host port with a conflicting port ID and the same worldwide port name (WWPN) as an already existing host port. You cannot enable the same port ID on SCSI host ports that have identical WWPNs.

User Response

Enable a different port on the SCSI host port with the same WWPN and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02493E

Unable to modify the SCSI host port. Another SCSI host port exists with the same worldwide port name and a conflicting port ID.

Explanation

You have attempted to modify a SCSI host port with a conflicting port ID and the same worldwide port name (WWPN) as an already existing host port. You cannot enable the same port ID on SCSI host ports that have identical WWPNs.

User Response

Ensure that you enable a different port on the SCSI host port with the same WWPN and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02494E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN02495E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN02496E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN02497E

The storage unit is busy. Wait for a few seconds, and resubmit the task.

Explanation

The task cannot complete because the storage unit is busy.

User Response

Wait for a few seconds until the server or storage unit is less busy, and resubmit the task.


CMUN02498E

The storage unit is busy. Wait for a few minutes, and resubmit the task.

Explanation

The task cannot complete because the storage unit is busy.

User Response

Wait for a few minutes until the server or storage unit is less busy, and resubmit the task.


CMUN02499E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN02500E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN02501E

Internal error. Contact your product technical support for assistance.

Explanation

The management console server reports an internal error.

User Response

Contact your product technical support for assistance.


CMUN02503E

The synchronize security repository task has failed because it exceeds the maximum number of user accounts.

Explanation

When you establish a peer relationship between management consoles, you have two options for processing user accounts.

  • Overwrite the user accounts on the secondary management console with the user accounts from the primary management console.
  • Synchronize the user accounts between the management consoles. This option adds the unique user accounts on the secondary management console to the user accounts on the primary management console.

You chose the synchronize option. The maximum number of user accounts for a management console is 100. The synchronize option has failed because there are more than 100 unique user accounts on the management consoles in the peer relationship that you are attempting to establish.

User Response

Remove the peer relationship between the management consoles. Establish it again, and select either the overwrite option or the synchronize option. If you select the synchronize option, first remove a sufficient number of unique user accounts to ensure that you do not exceed the maximum of 100 unique user accounts.


CMUN02506E

Operation failed: A VM host command has set a Special Intercept Condition (SIC) on the source or target volume.

Explanation

You are attempting a FlashCopy operation and the operation has failed because a VM host has set a Special Intercept Condition (SIC) on the FlashCopy source or target volume. This SIC is set by a VM host to prevent access to a volume by certain operations. You must reset the SIC to use the command-line interface (CLI) to perform the FlashCopy operation on these volumes, or you can use VM host commands to perform the FlashCopy operation. You cannot perform a FlashCopy operation using the CLI to a source or target volume that is connected to a VM host.

User Response

Make sure you have selected the correct FlashCopy source and target volumes. If you want to remove the SIC, you must detach the volume from the VM host. Resubmit the CLI FlashCopy operation or use VM host commands to perform the FlashCopy operation. If the problem persists, contact your product technical support for assistance.


CMUN02507E

Unable to submit the logical configuration task that you have requested because a discovery task is in progress.

Explanation

The logical configuration task that you have attempted has failed because it cannot be submitted while a discovery task is in progress.

User Response

Wait until the discovery task has completed successfully and resubmit the logical configuration task.


CMUN02508E

You are attempting to enter a notification e-mail address and the task has failed because the e-mail address is not valid.

Explanation

If you enable notification, you must define at least one notification e-mail address or a contact information e-mail address. Notification e-mail addresses must conform to the following format requirements.

  • You cannot enter more than three e-mail addresses.
  • You cannot enter data after the last e-mail address.
  • An e-mail address cannot contain a space character.
  • You must separate e-mail addresses with a comma. The number of commas must be one less than the number of e-mail addresses.
  • The maximum length of an e-mail address is 256 characters.
  • The maximum combined total length of all e-mail addresses cannot exceed 771 characters.
  • Each e-mail address must contain exactly one @ character.

User Response

Enter a notification or contact information e-mail address that meets the format requirements and resubmit the task, or disable the e-mail notification.


CMUN02509E

You are attempting to enter a contact information e-mail address and the task has failed because the contact information e-mail address is not valid.

Explanation

The contact information e-mail address must conform to the following format requirements.

  • An e-mail address cannot contain a space character.
  • The maximum length of a contact information e-mail address is 128 characters.
  • An e-mail address must contain exactly one @ character.

User Response

Enter a contact information e-mail address that meets the format requirements and resubmit the task.


CMUN02513E

The licensed internal code (LIC) activation key task has failed because at least one of the servers of the storage image is not currently operational.

Explanation

Both servers of the storage image must be operational when you install the LIC activation key.

User Response

Ensure that both servers of the storage image are operational and then resubmit the task.


CMUN02514E

You must use the standard ASCII 7-bit character set to enter data.

Explanation

You have entered data using a coded character set that is not supported.

User Response

Use the standard ASCII 7-bit character set to enter data and resubmit the command.


CMUN02515E

Remote Mirror and Copy activation codes are not supported for this model.

Explanation

For this model, Remote Mirror and Copy activation codes have been replaced with Metro Mirror and Global Mirror activation codes.

User Response

Activate a Metro Mirror activation code, a Global Mirror activation code, or both.


CMUN02516E

Metro Mirror activation codes are not supported for this model.

Explanation

If you want to enable the Metro Mirror feature for this model, use a Remote Mirror and Copy activation code.

User Response

Activate a Remote Mirror and Copy activation code.


CMUN02517E

Global Mirror activation codes are not supported for this model.

Explanation

If you want to enable the Global Mirror feature for this model, use a Remote Mirror and Copy activation code.

User Response

Activate a Remote Mirror and Copy activation code.


CMUN02518E

The Apply Activation code task has failed because the capacity that is configured on the storage image exceeds the capacity of the storage scope that is specified in the activation key.

Explanation

A storage scope is fixed block (FB), count key data (CKD), or all. You cannot apply an activation code that has an activation key capacity and scope that is smaller than the capacity that is currently configured on the storage image.

User Response

Purchase an activation code that has a capacity for the storage scope that is greater than or equal to the capacity that is currently configured on the storage image, and apply the new activation code.


CMUN02519E

The remote power control task has failed because an internal error has occurred. Contact your product technical support for assistance.

Explanation

Either the current storage unit power state could not be determined, or an operation failure has occurred.

User Response

Contact your product technical support for assistance.


CMUN02520E

The remote manual power control request has failed because the remote power control mode is not set to Remote manual.

Explanation

You must set the remote power control mode to Remote manual to support a remote manual power control request.

User Response

If you want to issue a remote manual power control request, change the remote power control mode to Remote manual and resubmit the request.


CMUN02521E

The remote manual power control request has failed because the local/remote switch on the storage unit is set to Local.

Explanation

You must set the local/remote switch on the storage unit to Remote and then you must ensure that the remote power control mode is set to Remote manual to support a remote manual power control request. The local/remote switch on the storage unit is currently not set to Remote.

User Response

If you want to issue a remote manual power control request, ask a service technician to set the local/remote switch on the storage unit to Remote and ensure that the remote power control mode is set to Remote manual and resubmit the request.


CMUN02522E

The remote manual power control request has failed because either the storage unit power state or the power control mode is transitioning.

Explanation

You cannot initiate a remote manual power control task while either the storage unit power state or the power control mode is transitioning.

User Response

Wait until the storage unit transition of power state or the power control mode has completed before you initiate another remote manual power control task.


CMUN02523E

The request to change the remote power control mode has failed because an internal error has occurred. Contact your product technical support for assistance.

Explanation

Either the current storage unit power state cannot be determined, or an operation failure has occurred.

User Response

Contact your product technical support for assistance.


CMUN02524E

The request to change the remote power control mode has failed because requested mode is not valid or is not supported.

Explanation

The remote power control mode that you have requested is not supported by the current version of microcode that is installed on the storage unit.

User Response

Request a change to a supported remote power control mode.


CMUN02525E

The remote power control mode cannot be changed to System z managed because the Remote power control feature hardware for System z (feature code 1000) is not installed.

Explanation

When you order hardware feature code 1000 (for MTM 2421-961), a service technician will install the logic card that supports the remote power control mode System z managed.

User Response

Select a different remote power control mode or contact your product technical support to order feature code 1000.


CMUN02526E

The change power control mode task that you have requested has failed because either the storage unit power state or the power control mode is transitioning.

Explanation

You cannot submit a task to change the power control mode if another change power control mode task is running or if the storage unit power state is transitioning.

User Response

Wait until the storage unit transition of power state or power control mode has completed before you initiate another change power control mode task.


CMUN02527E

The apply activation code task has failed because the version of microcode on at least one of the partitions is not supported, or the firmware on at least one of the host adapters on the storage unit is not supported.

Explanation

The version of microcode on the partitions must be identical to each other and the version of firmware on all of the host adapters on the storage unit must match the version of microcode on the partitions. In addition, the microcode and firmware versions must support the activation code that you are attempting to apply.

User Response

Ensure that the version of microcode that is installed on both partitions is identical and that the version of firmware on all of the host adapters on the storage unit matches the version of microcode on the partitions. Ensure that the version of microcode on the partitions and the version of firmware on the host adapters on the storage unit support the activation code that you are attempting to apply, and resubmit the task.


CMUN02528E

The task has failed because a Resource Manager error has occurred.

Explanation

The failed task has attempted to change the array status to a status of unavailable or a status of unassigned. The Resource Manager error has prevented the change array status task from completing successfully.

User Response

Contact your product technical support for assistance.


CMUN02529E

An internal parameter or value that is used by the task is not correct.

Explanation

The task has failed because a Resource Manager error has occurred.

User Response

Contact your product technical support for assistance.


CMUN02530E

The change machine type and machine serial number task has failed.

Explanation

The task attempts to change the machine type and the machine serial number for several internal resources. At least one change internal resource task has failed.

User Response

Contact your product technical support for assistance.


CMUN02531E

The query volume serial number task has failed.

Explanation

An error has occurred while attempting to retrieve the logical volume serial number.

User Response

Contact your product technical support for assistance.


CMUN02532E

The query rank extents task has failed.

Explanation

An error has occurred while attempting to retrieve the logical volume extents.

User Response

Contact your product technical support for assistance.


CMUN02533E

The create volume task has failed because the segment pool has no assigned ranks.

Explanation

A segment pool must have at least one assigned rank before you can create a volume using the pool.

User Response

Ensure that you have specified the correct segment pool. Ensure that at least one rank is assigned to the segment pool, and resubmit the task.


CMUN02534E

The operation has failed because the activation codes that you have specified are not supported for the current model.

Explanation

The management console server has detected LIC activation codes that are not valid.

User Response

Contact your product technical support for assistance.


CMUN02535E

The change machine type and machine serial number task has failed.

Explanation

The task attempts to change the machine type and machine serial number for the volume group and SCSI host port. At least one of these change tasks has failed.

User Response

Contact your product technical support for assistance.


CMUN02536E

Operation failure: The storage image is not available.

Explanation

The storage image must be available to perform this operation.

User Response

Contact your product technical support for assistance.


CMUN02537E

Operation failure: The storage image is not available.

Explanation

The management console server reports a storage unit microcode-level error.

User Response

Contact your product technical support for assistance.


CMUN02538E

Operation failure: A LIC parameter is not correct.

Explanation

The management console server has detected an incorrect LIC parameter.

User Response

Ensure that you have specified the command parameter correctly, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02539E

The expand logical volume task was not initiated because the volume is in a Copy Services relationship.

Explanation

You cannot expand the capacity of a logical volume while it is in a Copy Services relationship.

User Response

Remove the logical volume from the Copy Services relationship, and resubmit the task.


CMUN02540E

The expand volume or expand safeguarded backup capacity task was not initiated because there are not enough extents.

Explanation

There is an insufficient number of available extents to expand the volume or the safeguarded backup capacity to the capacity that you have requested.

User Response

Ensure that there are enough available extents, and resubmit the task.


CMUN02541E

The expand logical volume task was not initiated because the logical volume capacity that you have requested is less than the current logical volume capacity.

Explanation

The logical volume capacity that you request must be equal to or greater than the current logical volume capacity.

User Response

Specify a logical volume capacity that is equal to or greater than the current logical volume capacity, and resubmit the task.


CMUN02542E

The expand volume or expand safeguarded backup capacity task was not initiated because the volume or safeguarded backup capacity that you have requested is not within the valid capacity range for the volume or safeguarded backup capacity data type.

Explanation

The volume data type is either fixed block or count-key-data. The capacity that you have requested is either less than the minimum capacity or greater than the maximum capacity for the data type.

User Response

Ensure that the volume capacity or safeguarded backup capacity that you request is within the supported capacity range for the volume or safeguarded backup capacity data type, and resubmit the task.


CMUN02543E

The logical volume cannot be expanded because it is a System i volume, is not a base volume, or its data type is neither FB or CKD model 3390.

Explanation

You cannot expand the logical volume capacity of an alias volume or a System i volume. Also, the data type must be FB or CKD model 3390.

User Response

Ensure that your selection is not an alias or a System i volume. Ensure that the data type is either FB or CKD model 3390, and resubmit the task.


CMUN02544E

The expand volume or expand safeguarded backup capacity task was not initiated because there is not enough storage unit resource available. Resubmit the task when the storage unit is less busy.

Explanation

The expand volume or expand safeguarded backup capacity task requires significant storage unit resource to complete successfully. At the time that you had submitted the expand volume or safeguarded backup capacity task, there was not enough available storage unit resource to complete the task successfully.

User Response

Wait until the storage unit is less busy, and resubmit the task.


CMUN02545E

The expand logical volume task was not initiated because at least one device adapter prerequisite condition does not exist.

Explanation

To submit the expand logical volume task, several device adapter prerequisite conditions must be met. At least one prerequisite condition does not exist.

User Response

Contact your product technical support for assistance.


CMUN02546E

The expand logical volume task was not initiated because at least one logical partition is not fully operational.

Explanation

Both logical partitions must be fully operational to expand the capacity of a logical volume.

User Response

Ensure that both logical partitions are fully operational, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02547E

The expand logical volume task was not initiated. The volume state has been set to NORMAL.

Explanation

The capacity that you requested was equal to the current capacity. At the time that you submitted the expand logical volume task, the logical volume configuration state was RECONFIGURING ERROR.

User Response

Contact your product technical support for assistance.


CMUN02548E

The expand logical volume task was not initiated because the configuration state of the logical volume that you have specified is RECONFIGURING ERROR.

Explanation

The configuration state of the logical volume that you have specified is RECONFIGURING ERROR. The expand logical volume task cannot be initiated when the configuration state of the logical volume is RECONFIGURING ERROR.

User Response

Contact your product technical support for assistance.


CMUN02549E

The expand logical volume task has failed. The task has been resubmitted, and the resubmitted task has also failed.

Explanation

If the expand logical volume task fails under certain circumstances, the task can be resubmitted. The original expand logical volume task has failed, and the resubmitted task has also failed.

User Response

Contact your product technical support for assistance.


CMUN02550E

The expand volume or expand safeguarded backup capacity task has failed. The storage unit cannot return the capacity definition to the original capacity.

Explanation

If the expand volume or expand safeguarded backup capacity task fails under certain circumstances, the storage unit attempts to revert the capacity definition to the original capacity that was defined before the task was submitted. In this circumstance, the storage unit cannot return the logical volume capacity definition to the original capacity that was defined before the task was submitted.

User Response

Contact your product technical support for assistance.


CMUN02551E

The expand logical volume task was not initiated because either the logical volume configuration state or the logical volume data state is not NORMAL.

Explanation

The expand logical volume task requires that the logical volume configuration state is NORMAL and that the logical volume data state is NORMAL.

User Response

Contact your product technical support for assistance.


CMUN02552E

The expand volume or expand safeguarded backup capacity task has failed. The storage unit cannot return the volume capacity or safeguarded backup capacity definition to the original capacity.

Explanation

If the expand volume or expand safeguarded backup capacity task fails under certain circumstances, the storage unit attempts to revert the volume capacity or safeguarded backup capacity definition to the capacity that was defined before the task was submitted. In this circumstance, the storage unit attempted and failed to return the volume capacity or safeguarded backup capacity definition to the capacity that was defined before the task was submitted.

User Response

Contact your product technical support for assistance.


CMUN02553E

The expand logical volume task has failed to initiate the volume flash initialization subtask.

Explanation

The logical volume capacity has been reset to the original capacity.

User Response

Contact your product technical support for assistance.


CMUN02554E

The expand volume or expand safeguarded backup capacity task has failed and the capacity has reverted back to the original capacity.

Explanation

If the expand volume or expand safeguarded backup capacity task fails under certain circumstances, the storage unit attempts to revert the capacity definition to the capacity that was defined before the task was submitted. In this circumstance, the storage unit successfully returns the capacity definition to the capacity that was defined before the task was submitted.

User Response

Contact your product technical support for assistance.


CMUN02555E

You cannot change the current logical volume data type to the data type that you have specified because the current logical volume capacity is not supported by the data type that you have requested.

Explanation

The current logical volume capacity is not in the range of capacities that is supported for the logical volume data type that you have specified.

User Response

Specify a data type that supports the current logical volume capacity, and resubmit the task.


CMUN02556E

The create rank task has failed because information about ranks is missing or is unavailable.

Explanation

Device adapter metadata is required to complete the create rank task. At least some of this data is missing or unavailable.

User Response

Contact your product technical support for assistance.


CMUN02557E

The create rank task has failed because required information about ranks cannot be obtained.

Explanation

The management console server reports a storage unit microcode-level error that caused a query to device adapter metadata to fail.

User Response

Contact your product technical support for assistance.


CMUN02558E

The delete rank task has failed because information about the rank is temporarily unavailable.

Explanation

For this model, Remote Mirror and Copy activation codes have been replaced with Metro Mirror and Global Mirror activation codes.

User Response

Contact your product technical support for assistance.


CMUN02559E

The delete rank task has failed while changing the configuration state.

Explanation

One of the subtasks of the delete rank task sets the configuration state of the rank to Deconfiguring. The delete rank task has failed because this subtask has failed.

User Response

Contact your product technical support for assistance.


CMUN02560E

The expand logical volume task has failed because the configuration state is RECONFIGURING and the logical volume capacity that you have requested is not identical to the previously requested capacity.

Explanation

You cannot change the requested capacity while a previous logical volume expansion task is still in progress.

User Response

Specify the identical requested capacity that you previously specified or wait until the logical volume configuration task has completed, and resubmit the task.


CMUN02561E

The requested capacity of the logical volume that you have specified is not supported by the host server operating system.

Explanation

You must specify a requested capacity that is supported by the operating system of the host server that accesses the logical volume.

User Response

Specify a requested capacity that is supported by the operating system of the host server that accesses the logical volume, and resubmit the task.


CMUN02562E

You are attempting to configure extents but the Database protection Licensed Internal Code feature is not activated.

Explanation

You must activate the Database protection Licensed Internal Code feature to configure extents. The feature is not required to clear a configuration.

User Response

Activate the Database protection Licensed Internal Code feature, and resubmit the task.


CMUN02563E

The task has failed while the database extent configuration was being saved to the storage image.

Explanation

An internal error has occurred.

User Response

Contact your product technical support for assistance.


CMUN02564E

The task has failed because either the storage type of the volume that you have specified is not Fixed Block (FB) or the block size is not 512 bytes.

Explanation

The version of the Database protection feature that you have installed only supports Fixed Block volumes with 512 byte blocks.

User Response

Specify a configuration using only Fixed Block volumes with 512 byte blocks, and resubmit the task.


CMUN02565E

The task has failed because a logical volume that you have specified is not defined to the storage image or the volume state is not Normal.

Explanation

You must first define a volume to the storage image before you can set the database protection on that volume. You can only use the Database protection feature to configure a volume when the volume state is Normal.

User Response

Ensure that all of the volumes in the configuration are defined and have a volume state of Normal, and resubmit the task.


CMUN02566E

The task has failed because at least one of the volumes in the configuration that you have specified has a volume state of Offline.

Explanation

All volumes in the configuration that you specify must have a state of Normal.

User Response

Ensure that all of the volumes in the configuration that you specify have a state of Normal, and resubmit the task.


CMUN02567E

The extent specification format in the task that you have requested is not supported.

Explanation

The value of the extent specification format is set internally and it is set to the value 1. A different value was specified in the task request. However, this value cannot be set by users.

User Response

Contact your product technical support for assistance.


CMUN02568E

The extent specification length in the task request is not supported.

Explanation

The value of the extent specification length is set internally and it is set to a value of 48. A different value was specified in the task request. However, this value cannot be set by users.

User Response

Contact your product technical support for assistance.


CMUN02569E

The task has failed because the number of extent specifications that you have requested is not supported.

Explanation

The number of extent specifications must be from 0 through 32, inclusive. Use a value of 0 to clear the configuration.

User Response

Specify from 0 through 32 extent specifications, and resubmit the task.


CMUN02570E

The task has failed because the length of the extent specification list is not consistent with the number of extent specifications that you have requested.

Explanation

The calculation for the expected length of the extent specification list is based on the number of extents that you have specified. The actual length of the extent specification list does not match the expected length.

User Response

Contact your product technical support for assistance.


CMUN02571E

The task has failed because a non-hexadecimal character has been used in an extent specification.

Explanation

The extent specification must contain only valid hexadecimal characters.

User Response

Ensure that you have entered the hexadecimal values correctly, and resubmit the task.


CMUN02572E

The task has failed because the starting block addresses in the extent specifications that you have requested are not in increasing order.

Explanation

The extent specifications for the configuration can contain multiple extents. If you choose to specify multiple extents, the extents must be specified in order. The order must be ascending by starting block address.

User Response

Ensure that the extent specifications are in the correct order, and resubmit the task.


CMUN02573E

The task has failed because an extent size that you have requested is less than 128 logical blocks.

Explanation

The minimum extent size that is supported by the Database protection feature is 128 logical blocks.

User Response

Ensure that all extent sizes that you specify are at least 128 logical blocks, and resubmit the task.


CMUN02574E

The task has failed because at least two extent specifications overlap.

Explanation

You cannot specify two extents where the start of the second extent is within the range of the first extent.

User Response

Ensure that no extent specifications overlap, and resubmit the task.


CMUN02575E

The task has failed because at least one extent specification that you have requested is outside the range of addresses that are contained on the logical volume that you have specified.

Explanation

Every extent specification range must be fully contained on the logical volume that you have specified.

User Response

Ensure that every extent specification is fully contained on the logical volume that you have specified, and resubmit the task.


CMUN02576E

The task has failed because proprietary application information that is associated with an extent specification is not correct.

Explanation

The proprietary application information is data that cannot be entered by a user. This is an internal application error.

User Response

Contact your product technical support for assistance.


CMUN02577E

The task has failed because a reserved or unsupported field that is associated with an extent specification is not set to zero.

Explanation

Reserved and unsupported fields contain data that cannot be entered by a user. This is an internal application error.

User Response

Contact your product technical support for assistance.


CMUN02578E

The task has failed because an internal protocol error has occurred.

Explanation

This error should not occur. This value cannot be set by users.

User Response

Contact your product technical support for assistance.


CMUN02579E

The task has failed because an internal protocol specifies that write operations are not validated.

Explanation

This error should not occur because the protocol must specify that write operations are validated. However, this value cannot be set by users.

User Response

Contact your product technical support for assistance.


CMUN02580E

The task has failed because an internal protocol specifies that read operations are validated.

Explanation

This error should not occur because the protocol must specify that read operations are not validated. However, this value cannot be set by users.

User Response

Contact your product technical support for assistance.


CMUN02581E

The create extent pool task has failed because the value for an internal variable is not valid.

Explanation

An internal error has occurred.

User Response

Contact your product technical support for assistance.


CMUN02582E

The modify extent pool task has failed because the value for an internal variable is not valid.

Explanation

An internal error has occurred.

User Response

Contact your product technical support for assistance.


CMUN02583E

The create extent pool task has failed because the value that you have entered for threshold percent is not an integer from 0 through 100, inclusive.

Explanation

Only integers of 0 - 100 for the threshold percent are valid.

User Response

Enter a valid value for threshold percent, and resubmit the task.


CMUN02584E

The modify extent pool task has failed because the value that you have entered for threshold percent is not an integer from 0 through 100, inclusive.

Explanation

Only integers of 0 - 100 for the threshold percent are valid.

User Response

Enter a valid value for threshold percent, and resubmit the task.


CMUN02585E

The create logical volume task has failed because the storage allocation method is not supported.

Explanation

An internal error has occurred. You might be specifying a storage allocation method that is not supported by the version of microcode that is installed on the storage image.

User Response

Ensure that the version of microcode that is installed on the storage image supports the allocation method that you specify, and resubmit the task. If the problem persists, contact your product technical support for assistance.


CMUN02586E

The create space-efficient logical volume task has failed. Either there is no virtual storage configured for the specified extent pool, or the state of the virtual storage for the specified extent pool is not Normal.

Explanation

You must configure virtual storage for an extent pool before you can create a space-efficient logical volume on that extent pool. Also, the virtual storage for the extent pool must have a state of Normal.

User Response

Ensure that you have created virtual storage for the specified extent pool. Ensure that the virtual storage for the specified extent pool has a state of Normal, and resubmit the task.


CMUN02587E

The create space-efficient logical volume task has failed. Either there is no FB space-efficient storage configured for the FB extent pool, or the state of the FB space-efficient storage for the specified extent pool is not Normal.

Explanation

You must configure space-efficient storage for an extent pool before you can create a space-efficient logical volume on that extent pool. Also, the space-efficient storage for the extent pool must have a state of Normal.

User Response

Ensure that you have created fixed block (FB) space-efficient storage for the specified extent pool. Ensure that the FB space-efficient storage for the specified extent pool has a state of Normal, and resubmit the task.


CMUN02588E

The create space-efficient logical volume task has failed. Either there is no CKD space-efficient storage configured for the CKD extent pool, or the state of the CKD space-efficient storage for the specified extent pool is not Normal.

Explanation

You must configure space-efficient storage for an extent pool before you can create a space-efficient logical volume on that extent pool. Also, the space-efficient storage for the extent pool must have a state of Normal.

User Response

Ensure that you have created CKD space-efficient storage for the specified extent pool. Ensure that the CKD