NVMe flash enclosure (HPFE Gen3)

The physical location identifier format is Rx-Fyy, where x is the rack number and yy is the enclosure number (01-08).

Table 1. Storage enclosure location codes (NVMe flash enclosure, 24 drive slots)
Part See
Drive modules Figure 1
Enclosure services manager (ESM) Figure 2
Storage enclosure midplane Figure 3
Storage enclosure power supply Figure 2
Figure 1. Storage enclosure locations, NVMe flash enclosure (front view)
Table 2. Storage enclosure location codes (front) (NVMe flash enclosure, 24 drive slots)
Location code Part name
U2107.D05.sssssss Storage enclosure
U2107.D05.sssssss-P3-Cx
(x = 1-24)
NVMe drive
Figure 2. Storage enclosure locations, NVMe flash enclosure (rear view)
Table 3. Storage enclosure location codes (rear) (NVMe flash enclosure, 24 drive slots)
Location code Part name
U2107.D05.sssssss-E1 Storage enclosure power supply
U2107.D05.sssssss-E2 Storage enclosure power supply
U2107.D05.sssssss-P1 Enclosure services manager (ESM)
U2107.D05.sssssss-P1-C1-Tx
(x = 1-2 top to bottom)
NVMe (mini-SAS HD) connector on ESM
Note: Connectors T3 and T4 are not used.
U2107.D05.sssssss-P2 Enclosure services manager (ESM)
U2107.D05.sssssss-P2-C1-Tx
(x = 1-2 top to bottom)
NVMe (mini-SAS HD) connector on ESM
Note: Connectors T3 and T4 are not used.
Figure 3. Storage enclosure fan module locations
Table 4. Storage enclosure internal location codes (NVMe flash enclosure, 24 drive slots)
Location code Part name
U2107.D05.sssssss-P3 Storage enclosure midplane
U2107.D05.sssssss-P3-Ax
(x = 1-6 left to right)
Storage enclosure fan module

Enclosure location codes that are used in MES installation instructions

Figure 4. Enclosure location codes (Model A01) (rear)
Figure 5. Enclosure location codes (Models A05, E05) (rear)