Use this procedure to exchange the FRUs in the order of their failure
probability.
Before you begin
All storage facility repair
activity should be started from Start here.
If you have not started from that procedure, go there now and start from the
section Analyze and repair problems. If you did start
from that section and the analysis procedures produced an SRN, then follow
the steps below.
Find the failing function codes in the f2c_flngfnctcdlst_21ktnp.html.
Use this list to help you find the part number of each FRU.
Obtain the replacement part.
Replace the FRU. If the FRU is listed in the serviceable event that
sent you here, use the serviceable event FRU
replace to continue the repair. If the FRU is not listed in the serviceable event FRU
list, use the HMC Service Focal
Point > Exchange Parts optionuse Storage
Facility Management > storage facility > Exchange Parts to select and replace
the FRU.