HAMLE

This topic describes the symbolic FRU for a host adapter microcode logic error (HA MLE).

About this task

This symbolic procedure shows the location of a host adapter that encountered a microcode logic error. The HA location is in logical format cpssfcbbc, where bb is the logical bay number (00 - 07) and c is the card number in the bay (2 -5). This information is to be used when reporting the MLE as discussed in the isolation procedure in the FRU list.
Table 1. Logical Bay Locations
Logical Bay Physical Bay Location
00 R1-XI1 U1700.1B1.sssssss
01 R1-XI2 U1700.1B2.sssssss
02 R1-XI3 U1700.1B3.sssssss
03 R1-XI4 U1700.1B4.sssssss
04 R2-XI1 U1700.2B1.sssssss
05 R2-XI2 U1700.2B2.sssssss
06 R2-XI3 U1700.2B3.sssssss
07 R2-XI4 U1700.2B4.sssssss
Table 2. Logical Card Locations
Logical Card Location
2 Un-P1-C3
3 Un-P1-C4
4 Un-P1-C5
5 Un-P1-C6