Management console, network, and power location codes (Models A05, E05)

Table 1. Rack power and cooling location codes (Model A05, E05)
Part See
iPDU pair, locations in rack Figure 1
iPDU pair, locations in vertical orientation Figure 2
IBM Power HMC Figure 3, Figure 4
Rack control hub Figure 5
Figure 1. iPDU pair, locations in rack (rear) (Models A05, E05)
Figure 2. iPDU pair, locations in vertical orientation (rear)
iPDU pair, locations in vertical orientation (rear)
Figure 3. IBM Power HMC (front)
Table 2. IBM Power HMC locations (front)
Label Management console location
1 Drive 0
2 Drive 1
3 Fan 0
4 Fan 1
5 Fan 2
6 Fan 3
7 Fan 4
8 Control panel
Figure 4. IBM Power HMC (rear)
Table 3. IBM Power HMC locations (rear)
Label Management console location / connection
1 Ethernet (gray) - eth3
2 Ethernet (customer) - eth2
3 Ethernet (customer secondary, if used) - eth1
4 Ethernet (black) - eth0
5 USB 2.0 serial communication to rack control hub - USB port 4
6 USB 2.0 to keyboard cable couplers (Note 1) - USB port 3
7 Direct BMC port (maintenance) - IPMI (not used in DS8000)
8 VGA to monitor cable couplers - VGA
10 Power supply unit 1 (left, labeled E0)
11 Power supply unit 0 (right, labeled E1)
Figure 5. Rack control hub locations
Table 4. Rack control hub locations
Label Rack control hub location
1 thru 10 Ethernet SWn-T1 thru T10
11 Serial communication (SWn-USB COM)
12 Partner rack control hub power LED
13 Partner power cable (SWn-PTNR PWR)
14 PSU / input power cord
15 Local rack control hub power LED