This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware
might occur when microcode and power boundaries are not in the proper conditions for this service
action.
If a serviceable event FRU repair directed you to this procedure, the microcode and power
boundaries are already set.
If there is no FRU identify indicator or location code, you were sent here by an isolation MAP
or symbolic FRU procedure. Use the information in that procedure and the figures in this procedure
to locate the proper part to exchange.
Most, but not all, FRUs have identify indicators. Use the flashing amber or solid blue FRU
identify indicators to ensure that you are working on the correct enclosure or FRU.
The "light path" identify LEDs are a hierarchy of LEDs that can identify the enclosure, FRU, and
even the FRU connector to which a cable is connected.
Attach the electrostatic discharge (ESD) wrist strap. The ESD wrist strap must be connected to
an unpainted metal surface until the service procedure is completed, and if applicable, until the
service access cover is replaced.
Attention:
Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack,
or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from
damaging your hardware.
When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is
used for static control. It does not increase or decrease your risk of receiving electric shock when
using or working on electrical equipment.
If you do not have an ESD wrist strap, just prior to removing the product from ESD
packaging and installing or replacing hardware, touch an unpainted metal surface of the system for a
minimum of 5 seconds. If at any point in this service process you move away from the system, it is
important to again discharge yourself by touching an unpainted metal surface for at least 5 seconds
before you continue with the service process.
Figure 1. Attaching the ESD wrist strap
At the front of the rack, loosen the front screws that secure the storage enclosure to the
rack.
Figure 2. Loosening the front screws
Slide the storage enclosure into the service position.
Figure 3. Sliding the enclosure into service position
Ensure that the screws inside the latches are not secured to the rack. Then, slide the storage
enclosure out of the rack until the slides click and hold the enclosure unit securely.
Ensure that the cable management arm can move freely. Ensure that the cables at the rear of the
storage enclosure do not catch or bind as you pull the enclosure unit into the service
position.
Note: The rack stabilizer brackets must be attached to the rack before any
drawer is installed or pulled out from the rack. Do not pull out more than one drawer at a time. The
rack might become unstable when more than one drawer at a time is pulled out from the rack.
Open the fan access door by lifting the D-rings on top of the storage enclosure and turning
them in a counterclockwise direction.
Figure 4. Opening the fan access door
Look for the amber fault LED to identify the failed fan.
Figure 5. Amber fault light
To remove a fan module, press in at the grip locations and lift the fan from the system.
To replace a fan module, lower the fan into the system and align the fan with the pins. Press
the fan down until it is fully seated and level with the other modules.
Figure 7. Replacing the fan module
Close the fan access door by lifting the D-rings on top of the storage enclosure, turning them
in a clockwise direction, and pushing the D-rings downward to the fan access door. Ensure that the
fan access door is closed.
Figure 8. Closing the fan access door
Unlock the blue rail safety latches by pushing them inward.
Slide the storage enclosure back into place, then push the storage enclosure unit back into the
rack until both release latches lock the enclosure into position. Ensure that the cable management
arm can move freely.
Figure 9. Sliding the enclosure back into the rack
Exit this service information center parts exchange procedure and return to the procedure that
sent you here.