CEC enclosure part numbers, Model A01
| Part name | Figure | Table |
|---|---|---|
| CEC enclosure cables (external) | Figure 3, Figure 4 | Table 5, Table 6 |
| Control panel | Figure 1 | Table 2 |
| Control panel display | Figure 1 | Table 2 |
| Ethernet adapter | Figure 3 | Table 4 |
| Fan | Figure 1 | Table 2 |
| Memory module | Figure 2 | Table 3 |
| NVDIMM | Figure 2 | Table 3 |
| NVDIMM backup power module (BPM) | Figure 2 | Table 3 |
| NVMe drive | Figure 1 | Table 2 |
| NVMe drive backplane | Figure 2 | Table 2, Table 3 |
| PCIe single-port card | Figure 3 | Table 4 |
| PCIe two-port card | Figure 3 | Table 4 |
| Power supply | Figure 3 | Table 4 |
| Processor module | Figure 2 | Table 3 |
| SAS RAID internal adapter | Figure 2 | Table 3 |
| Service processor card | Figure 3 | Table 4 |
| System backplane | Figure 2 | Table 3 |
| Time-of-day battery | Figure 2 | Table 3 |
| Trusted platform module (TPM) card | Figure 2 | Table 3 |
| Vital product data (VPD) card | Figure 2 | Table 3 |
| Location code | Part name | CCIN (see note) |
Part number |
|---|---|---|---|
| Un-A1 to A4 | Fan | 6B5F | 01GY151 |
| Un-D1 | Control panel | 6B5C | 00VK541 |
| Control panel cable | 01GY455 | ||
| Un-D2 | Control panel display | 6B5D | 00VK547 |
| Control panel display cable and holder | 01ML097 | ||
| Un-P1-T3 Un-P1-T4 |
Not used | ||
| Un-P2 | NVMe drive backplane | 2D3B | 01DH247 |
| Un-P2-C1 Un-P2-C2 |
800 GB NVMe U.2 drive | 5949 | 02YC661 |
|
Important: Read this entire note as there are exceptions to what part number to order.
The custom card identification number (CCIN) identifies the physical features and logical behavior
of a part. If two parts appear physically identical but have different CCINs, they are not
interchangeable unless stated elsewhere in the maintenance package or by the next level of support.
If two parts have different part numbers and yet have the same CCIN, they are interchangeable.
When you order a part number reported in a serviceable event or call home record, check whether the parts-ordering system has a conditional substitute for DS8000®. There are some exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number that is reported and called home might be the original IBM® Power® part number that might have firmware that is not appropriate for DS8000. Order the DS8000 FRU part number to ensure that the correct firmware is present. |
|||
| Location code | Part name | CCIN (see note 1) |
Part number |
|---|---|---|---|
| Un-P1 | System backplane (9009-22G) | 2E2C | 00E5437 |
| Un-P1-C1-E1 | Time-of-day battery | 74Y9628 | |
| Un-P1-C13 | Vital product data (VPD) card (9009-22G) (see note 2) | 565F | 02AT207 |
| Un-P1-C14 | Trusted platform module (TPM) card | 6B5A | 00VK519 |
| Un-P1-C15 to C46 (except C22, C36) |
Memory module filler | 01GY204 | |
| Un-P1-C15 to C46 (except C22, C36) |
Memory module, 16 GB IS RDIMM | 324E | 78P7317 |
| Un-P1-C15 to C46 (except C22, C36) |
Memory module, 32 GB IS RDIMM | 324F | 78P7318 |
| Un-P1-C22, Un-P1-C36 |
NVDIMM, 16 GB Replace like-for-like only |
330A | 03NJ750 |
| Un-P1-C22-T1, Un-P1-C36-T1 |
16 GB NVDIMM backup power module (BPM) cable, 340 mm | 03FP027 | |
| Un-P1-C22-T1-E1 (P2-D7) Un-P1-C36-T1-E1 (P2-D7) (single BPM located in P2-D7) |
16 GB NVDIMM backup power module (BPM) | 03FP003 | |
| Un-P1-C47 Un-P1-C48 |
System processor module FRU kit, 8-core (9009-22G) (Kit includes processor module and replacement tools. Module cannot be ordered separately.) (see note 4) |
5C3B | 02DE682 |
| Un-P1-C47 Un-P1-C48 |
System processor module heat sink kit (Kit includes heat sink, TIM, and tweezers) |
01EM317 | |
| Un-P1-C49 | NVMe U.2 pass-thru card | 03FL275 | |
| Un-P1-C49-E1 | Not used | ||
| Un-P1-C50 | Not used | ||
| Un-P2 | NVMe drive backplane | 2D3B | 01DH247 |
| P2-D7 / Un-P1-C22-T1-E1 P2-D7 / Un-P1-C36-T1-E1 |
16 GB NVDIMM backup power module (BPM) (see note 3) | 03FP003 | |
| Un-P2-D8 | Not used | ||
|
Note 1: Important: Read this entire note as there are exceptions to
what part number to order. The custom card identification number (CCIN) identifies the physical
features and logical behavior of a part. If two parts appear physically identical but have different
CCINs, they are not interchangeable unless stated elsewhere in the maintenance package or by the
next level of support. If two parts have different part numbers and yet have the same CCIN, they are
interchangeable.
When you order a part number reported in a serviceable event or call home record, check if the parts-ordering system has a conditional substitute for DS8000. There are some exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number that is reported and called home might be the original IBM® Power® part number that might have firmware that is not appropriate for DS8000. Order the DS8000 FRU part number to ensure that the correct firmware is present. Note 2: VPD card is a storage-unique part. Do not use the server
version.
Note 3: NVDIMM BPM logical locations
Un-P1-C22-T1-E1 and Un-P1-C36-T1-E1 both point to the same
BPM, located at Un-P2-D7
Note 4: Use the CCIN of the system processor or memory
module that you are replacing to determine the correct FRU to order.
|
|||
| Location code | Part name | CCIN1 | Part number |
|---|---|---|---|
| Un-E1 Un-E2 |
CEC enclosure power supply 1600 W (Replace like-for-like only) |
2B1E | 03RV107 |
| Un-P1-C1 | Service processor card | 2DEA | 02PX093 |
| Un-P1-C4 | Not used | ||
| Un-P1-C6 Un-P1-C8 Un-P1-C9 Un-P1-C12 |
PCIe single-port card | 2E1B | 03NJ564 03NJ478 |
| Un-P1-C10 | Ethernet adapter (10 Gb 2-port), FC AAH0 (server FC EC71) MUST ORDER QTY 2 SFPs (below) with this adapter |
2CF9 | 03HD074 |
| Un-P1-C10-T1 Un-P1-C10-T2 |
10 Gb SR optical SFP (server FC EB46) Order qty 2 SFPs when replacing Ethernet adapter C10. |
01FT829 | |
| Un-P1-C11 | Ethernet adapter (10/1 Gb four-port, server FC EN2X) | 2F04 | 03JP016 |
| Un-P1-C2 Un-P1-C3 |
Not used | ||
| Un-P1-T1 Un-P1-T2 |
Not used |
| Location code | Part name | Part number |
|---|---|---|
| Un-P1-C6-T1 Un-P1-C8-T1 Un-P1-C9-T1 Un-P1-C12-T1 |
PCI cable FRUs | See Figure 4 and Table 6. |
| Un-P1-C1-T1 ("HMC 1") | Ethernet cable (SW2 to upper CEC XC1 service processor) (black network) | 03NJ727 |
| Ethernet cable (SW2 to lower CEC XC2 service processor) (black network) | 03NJ727 | |
| Un-P1-C1-T2 ("HMC 2") | Ethernet cable (SW1 to upper CEC XC1 service processor) (gray network) | 03NJ727 |
| Ethernet cable (SW1 to lower CEC XC2 service processor) (gray network) | 03NJ727 | |
| Un-P1-C11-T1 | Ethernet cable (SW2 to upper CEC XC1 LPAR, black network) | 03NJ727 |
| Ethernet cable (SW2 to lower CEC XC2 LPAR, black network) | 03NJ727 | |
| Un-P1-C11-T2 | Ethernet cable (SW1 to upper CEC XC1 LPAR, gray network) | 03NJ727 |
| Ethernet cable (SW1 to lower CEC XC2 LPAR, gray network) | 03NJ727 |
| From CEC R1-XC1 | To Rack 1 I/O Enclosure | Figure 4 index | Cable FRU part number |
|---|---|---|---|
| R1-XC1-P1-C6-T1 | (1B1) R1-XI1-P1-C7-T1 | 0A | 02AT154 |
| R1-XC1-P1-C8-T1 | (1B2) R1-XI2-P1-C7-T1 | 1A | 02AT154 |
| R1-XC1-P1-C9-T1 | (1B3) R1-XI3-P1-C7-T1 | 2A | 02AT154 |
| R1-XC1-P1-C12-T1 | (1B4) R1-XI4-P1-C7-T1 | 3A | 02AT154 |
| From CEC R1-XC2 | To Rack 1 I/O enclosure | Figure 4 index | Cable FRU part number |
| R1-XC2-P1-C6-T1 | (1B1) R1-XI1-P1-C7-T2 | 0B | 02AT154 |
| R1-XC2-P1-C8-T1 | (1B2) R1-XI2-P1-C7-T2 | 1B | 02AT154 |
| R1-XC2-P1-C9-T1 | (1B3) R1-XI3-P1-C7-T2 | 2B | 02AT154 |
| R1-XC2-P1-C12-T1 | (1B4) R1-XI4-P1-C7-T2 | 3B | 02AT154 |
|
Note: FRU kit contains PCIe cable and label sheets.
|
|||