Exchange the CEC enclosure system processor module
Before you begin
CAUTION:
This assembly contains mechanical moving parts. Use care when
you service this assembly. (C025)

Attention:
- This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware might occur when microcode and power boundaries are not in the proper conditions for this service action.
- If a serviceable event FRU repair directed you to this procedure, the microcode and power boundaries are already set.
- If a serviceable event FRU repair did not direct you to this procedure, see MAP1230 Replace a FRU without using a serviceable event.
Notes:
- All the cables and FRUs to be removed must be uniquely identified so they can be reinstalled correctly.
Preparing the CEC enclosure to remove and replace the system processor module
Procedure
- Use a replacement part with a valid DS8000® part number to ensure it has the proper firmware, VPD, and/or configuration to ensure it is compatible with the DS8000 service procedures. Attempting to use a generic server FRU might fail and require next level of support to recover.
-
All parts being removed must be marked or identified so they can be installed into their
original locations.
Note: Failure to mark or identify parts can extend the service duration and may require next level of support assistance.
-
Use the front and rear blue identify LEDs to determine the CEC enclosure to be repaired. Both
blue LEDs should be lit.
- CEC control panel blue identify LED
as shown in Figure 1. - CEC enclosure rear blue identify LED
as shown in Figure 2.
Note: If both the front and rear CEC enclosure identify LEDs are not lit, use the location code listed in the serviceable event FRU list. See MAP1245 Finding FRUs by using location codes.Figure 1. Control panel LEDs 
Figure 2. CEC enclosure rear LEDs 
- CEC control panel blue identify LED
-
Verify that the CEC enclosure is in the power-off state. See Figure 3
- At the rear of the CEC enclosure, view all CEC enclosure power supply DC LEDs.
-
Are all DC (output) LEDs flashing?
- Yes, continue with the next step.
- No, do not continue with this FRU replacement. Go to MAP4841 CEC enclosure fails to power off during service processor repair (Models A0x).
Figure 3. Location of the power supplies and LEDs (Model A01)
-
Disconnect the power cords
from the CEC with the DC
(output) LEDs flashing. See Figure 4.
Notes:- Ensure the power cords are correctly labeled.
- The power supply LEDs might continue to flash for up to 20 seconds while internal power is discharged.
- The power cord is fastened to the system using the hook-and-loop fastener
. Unstrap the fastener to allow
the enclosure to be placed in the service position.
Figure 4. Removing the power cords (Model A01) 
-
Observe the CEC enclosure control panel green power button LED
. See Figure 5.
- If it is off, go to the next step.
- If it is flashing, the CEC enclosure is still in the power-off state. DO NOT CONTINUE. Ensure that you have unplugged the power cables.
Figure 5. Control panel LEDs 
-
Attach the electrostatic discharge (ESD) wrist strap. The ESD wrist strap must be connected to
an unpainted metal surface until the service procedure is completed, and if applicable, until the
service access cover is replaced.
Attention:
- Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack, or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging your hardware.
- When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is used for static control. It does not increase or decrease your risk of receiving electric shock when using or working on electrical equipment.
- If you do not have an ESD wrist strap, just prior to removing the product from ESD packaging and installing or replacing hardware, touch an unpainted metal surface of the system for a minimum of 5 seconds. If at any point in this service process you move away from the system, it is important to again discharge yourself by touching an unpainted metal surface for at least 5 seconds before you continue with the service process.
Figure 6. Location of ESD plugs 
-
Disconnect all remaining cables from the rear of the CEC enclosure. See Table 1 and Figure 7.
Table 1. CEC enclosure cable connections Connection Description P1-C1-T1 (HMC 1) FSP Ethernet P1-C1-T2 (HMC 2) FSP Ethernet P1-C6-T1 PCIe to I/O enclosures P1-C8-T1 PCIe to I/O enclosures P1-C9-T1 PCIe to I/O enclosures P1-C10-T1, P1-C10-T2 Customer network (optional feature, if used) P1-C11-T1, P1-C11-T2 LPAR Ethernet P1-C12-T1 PCIe to I/O enclosures Figure 7. CEC enclosure location codes (rear view) (Model A01)
-
Place the CEC enclosure into the service position.
-
Open the side latches
and pull the latches to slide the system unit fully into the service position, until the slides
click and hold the system unit securely.
- Ensure that the screws inside the latches are not secured to the rack. See Figure 8.
Figure 8. Releasing the side latches 
-
Open the side latches
-
Remove the service access cover.
- Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface.
-
Release the service access cover latch by pushing the release latch
in the direction shown.
-
Slide the cover
off
the system unit. When the front of the service access cover clears the upper frame ledge, lift the
cover up and off the system unit.
Attention: For proper cooling and airflow, replace the cover before turning on the system.
Figure 9. Removing the service access cover 
-
To activate the identify LED for the faulty part, press and hold push-button
on the trusted platform module
card as shown in Figure 10. Verify that the LED
is lit, which indicates that
sufficient power exists for the identify LED. If the LED
is not lit, use the location
code to find the physical location by using the service label.
Figure 10. Activating the identify LED 
Removing the CEC enclosure system processor module
To remove a system processor module, complete the steps in this procedure.
Before you begin
Procedure
- Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface.
-
Open the packaging of the new system processor module, and place the cover upside down next to
the tray, as shown in Figure 11. The cover is used for
the system processor module that you are replacing.
Figure 11. Opening the system processor module packaging 
-
Remove the heat sink from the system processor module.
CAUTION:(L007) A hot surface nearby.

-
Loosen the heat sink actuation screw by turning the supplied hex key counterclockwise
. Loosen the screw until it moves
freely. See Figure 12.
-
Grip the heat sink
on opposing sides and remove the heat sink by lifting it upward. Set the heat sink aside with the
module side facing upward.
Note: If you plan to remove dust or debris from the heat sink, this operation must be performed in another room that is greater than 7.6 m (24.9 ft) away from the work area.Figure 12. Removing the heat sink 
-
Loosen the heat sink actuation screw by turning the supplied hex key counterclockwise
-
Using the supplied tweezers, remove the TIM from the top of the system processor module and
place it in a clean, dry area as shown in Figure 13.
Note: Be careful not to damage the TIM as it is very light and fragile.
Figure 13. Removing the TIM from the system processor module 
-
Prepare the system processor module for removal:
-
Ensure that the removal tool
is in the open position as shown
in Figure 14. The middle ring
must be pushed down and blue
tabs
must be turned
inward.
Figure 14. Ensuring the removal tool is in the open position 
-
Align the tool over the system processor module. Ensure that the beveled edge on the tool
aligns with the beveled edge of the system processor module
as shown in Figure 15.
-
Lower the tool over the system processor module. Ensure that the two guide pins
insert into the alignment holes
on each side of the tool
as shown in Figure 15.
Figure 15. Lowering the removal tool onto the system processor module 
-
With the removal tool sitting on top of the system processor module, push down on the ring
slightly so that the blue
tabs
snap outward and the
jaws engage with the system processor module as shown in Figure 16. Make sure that both of the tool jaws are locked onto the system processor module by
pushing down on the tool.
Important: Do not press the blue release ring until directed to do so later.Figure 16. Locking the system processor module into the tool 
-
Ensure that the removal tool
-
Hold the outside of the tool and lift the tool and system processor module from the socket.
Lift the tool upward slowly to ensure that the jaws are fully engaged with the system processor
module. Ensure that the system processor module does not disengage and fall back into the socket of
the system processor module. If the system processor module falls back into the socket of system
processor module, the pins may be damaged. Place the system processor module at an angle on the top
cover of the packaging as shown in Figure 17. Setting the
tool and system processor module at an angle on the top cover of the system processor module
packaging makes it easier to place the system processor module in the packaging.
Figure 17. Placing the tool on the system processor module tray 
-
Release the system processor module by pushing the ring
downwards. Hold the ring
down while pushing the blue tabs
inward as shown in Figure 18. Ensure that the ring catches the openings on the
blue tabs, and that the blue tabs are locked in a fixed position. To prevent the system processor
module from falling, pull up on the round lever before you place the tool on the top cover of the
system processor module packaging.
Figure 18. Releasing the system processor module from the tool 
Replacing the CEC enclosure system processor module
To replace a system processor module in the system, complete the steps in this procedure.
Procedure
- Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface.
-
Prepare the system processor module for installation:
-
Ensure that the removal tool is in the open position as shown in Figure 14. The middle ring must be pushed down and blue tabs
must be turned inward.
Figure 19. Ensuring the removal tool is in the open position 
-
Lower the tool over the system processor module as shown in Figure 20. Ensure that the beveled edge on the tool
aligns with the beveled edge of the system processor module. Ensure that the two guide pins
are inserted into the alignment
holes
on each side of the
tool.
Figure 20. Lowering the removal tool onto the system processor module 
-
With the removal tool sitting on top of the system processor module, push down on the ring
slightly so that the blue
tabs
snap outward and the
jaws engage with the system processor module
as shown in Figure 21. Make sure that both of the tool jaws are locked onto the
system processor module by pushing down on the tool.
Important: Do not press the blue release tabs until directed to do so later.Figure 21. Locking the system processor module into the tool 
-
Ensure that the removal tool is in the open position as shown in Figure 14. The middle ring must be pushed down and blue tabs
must be turned inward.
-
Install the system processor module:
-
If dust or debris is present on the system processor socket, use the supplied air pump to clean
the socket. Blow small bursts of air from the center toward the sides of the socket, as shown in
Figure 22.
Figure 22. Removing dust and debris from the system processor socket 
- Hold the sides of the tool with system processor module and carefully lift the tool out of the system processor module tray.
-
Lower the tool and system processor module onto the socket. Align the beveled corner of the
tool with the beveled corner on the socket. Align the guide pins
with the alignment holes
on each side of the tool. Use
care to lower the tool evenly without tilting the tool. See Figure 23.
Note: Do not attempt to slide the tool and the system processor module in any direction while the system processor module is touching the socket. If the tool and the system processor module are not aligned with the guide pins, lift the tool and the system processor module and reposition them.Figure 23. Installing the system processor module 
-
Open the latches that hold the system processor module in the supplied removal tool
as shown in Figure 24. Push down on the ring
while pressing in on the tabs
.
Figure 24. Removing the system processor module tool 
- Lift the tool off the system processor module.
-
If dust or debris is present on the system processor socket, use the supplied air pump to clean
the socket. Blow small bursts of air from the center toward the sides of the socket, as shown in
Figure 22.
-
Inspect the thermal interface material (TIM) for visible signs of damage, as shown in Figure 25.
Figure 25. Inspecting the thermal interface material 
- Choose one of the following repair options:
-
Use this step to install a new TIM and reuse the existing heat sink.
- Open the TIM packaging and carefully remove the TIM, holding it by the edges of the carrier strip and holding it away from the shipping container.
-
Remove the protective film from the clear carrier strip by using the supplied tweezers.
Note: The TIM must remain flat. Small wrinkles are acceptable, but folds are not acceptable.
-
Using the tweezers, remove the TIM from the carrier strip and center it onto the system
processor module. The TIM has no preferred up-side. The TIM can be placed on the system processor
module and centered as shown in Figure 26.
Figure 26. Installing a new TIM onto the system processor module
-
Place the heat sink on the TIM as shown in Figure 27.
Figure 27. Installing the heat sink on the TIM
-
To reuse the existing undamaged TIM and heat sink:
-
Using the tweezers, move the old processor's TIM from the clean, dry surface and center it onto
the new system processor module. The TIM has no preferred up-side. The TIM can be placed on the
system processor module and centered as shown in Figure 28.
Figure 28. Moving the TIM onto the system processor module
-
Place the heat sink on the TIM as shown in Figure 29.
Figure 29. Installing the heat sink on the TIM 
-
Using the tweezers, move the old processor's TIM from the clean, dry surface and center it onto
the new system processor module. The TIM has no preferred up-side. The TIM can be placed on the
system processor module and centered as shown in Figure 28.
-
Secure the TIM and heat sink to the socket of the system processor module.
-
Ensure that the heat sink load arms are engaged as shown by
in Figure 30.
-
Tighten the center load screw clockwise by using the supplied hex key as shown by
in Figure 30 until a firm stop is reached. If the heat sink moves
noticeably, the load arms are not engaged. Unscrew the center load screw and repeat this step
again.
Figure 30. Tightening the center load screw on the heat sink 
-
Ensure that the heat sink load arms are engaged as shown by
-
Lightly grip the system processor module that you replaced by the edges and lift it off of the
packaging cover. Align the beveled corner of the module
to the corner of the packaging
with triangle
and place
it in the packaging, as shown in Figure 31. Close the
packaging cover.
Figure 31. Placing the system processor module into the packaging 
Preparing the CEC enclosure for operation after removing and replacing the system processor module
About this task
To prepare the system for operation, complete the following steps:
Procedure
- Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface.
-
Replace the service access cover. See Figure 32.
-
Slide the cover
onto
the system unit.
-
Close the latch release
by pushing it in the direction
shown.
Figure 32. Installing the service access cover 
-
Slide the cover
-
Place the CEC enclosure into the operating position.
-
Unlock the blue rail safety latches
as shown in Figure 33 by pushing them inward.
-
Push the system unit
all the way into the rack until both release latches lock the system into the operation
position.
- Secure the enclosure to the rack with screws, if screws were loosened when preparing the enclosure for service.
Figure 33. Placing the CEC enclosure into the operating position 
-
Unlock the blue rail safety latches
- Attach the electrostatic discharge (ESD) wrist strap.
-
Reconnect all cables, except for power cords. See Table 2 and Figure 34.
If optical Ethernet connections are used, use proper cleaning procedures.Important: The optical cable plugs (LC connectors) and ports (SFPs) must be cleaned before connecting them. Use cleaning tool 54Y4392 or IBM-approved alternative. After cleaning SFPs with the tool, use air bulb 45D2645 or IBM-approved alternative. For detailed procedures, refer to current DS8000 Info Alerts or contact your next level of support.
Table 2. CEC enclosure cable connections Connection Description P1-C1-T1 (HMC 1) FSP Ethernet P1-C1-T2 (HMC 2) FSP Ethernet P1-C6-T1 01PCIe to I/O enclosures P1-C8-T1 PCIe to I/O enclosures P1-C9-T1 PCIe to I/O enclosures P1-C10-T1, P1-C10-T2 Customer network (optional feature, if used) P1-C11-T1, P1-C11-T2 LPAR Ethernet P1-C12-T1 PCIe to I/O enclosures Figure 34. CEC enclosure location codes (rear view) (Model A01)
-
Reconnect the power cords
to the CEC enclosure. See Figure 35.
-
Fasten the power cords to the enclosure using the hook-and-loop fasteners
.
Figure 35. Connecting the power cords 
-
Verify that the CEC enclosure has power available. See Figure 36.
- At the rear of the CEC enclosure, view the CEC enclosure power supply DC LEDs.
-
Are all DC (output) LEDs flashing?
- Yes, continue with the next step.
- No, ensure the power cords are properly connected. If no connection problem is found, contact your next level of support.
Figure 36. Location of the power supplies and LEDs (Model A01)
-
Wait up to 5 minutes for the CEC enclosure control panel power button LED
to flash. See Figure 37.
Note: Waiting ensures that the CEC enclosure is in the power-off state.Is the power button LED flashing?
- Yes, go to the next step.
- No, ensure the CEC enclosure power supplies are fully seated. The possible failing FRUs are the CEC enclosure system backplane and control panel. You can also call the next level of support.
Figure 37. Control panel LEDs 
- Close the rear door of the rack.
- Exit this service information center parts exchange procedure and return to the procedure that sent you here.