Operating vibration and shock requirements

The vibration levels that are designed for the storage system comply with class V1 requirements included in the product classes for vibration.

The storage system is designed to operate under the vibration V1 levels that are described in Table 1. Additional information includes random vibration PSD profile breakpoints and operational shock levels. See Table 2 and Table 3.
Table 1. Vibration levels
Class grms g Peak Sine 1, 2
V1L 0.10 0.06 @ 50 and 60 Hz
Notes:
  1. All values in this table are in g2/Hz
  2. g is the peak g level of an approximate half-sine pulse.
Table 2. Random vibration PSD profile breakpoints
Class 5 Hz 17 Hz 45 Hz 48 Hz 62 Hz 65 Hz 150 Hz 200 Hz 500 Hz
V1L 2.0x10-7 2.2x10-5 2.2x10-5 2.2x10-5 2.2x10-5 2.2x10-5 2.2x10-5 2.2x10-5 2.2x10-5
Note: All values in this table are in g2/Hz.
Table 3. Operational shock levels
Class Axis g1 pw2
S1 Vertical 3.5 3.0
Notes:
  1. g is the peak g level of an approximate half-sine pulse.
  2. pw is the pulse width in milliseconds.