VMware ESXi/ESX host attachment

If you have a VMware ESXi/ESX server, learn the requirements and procedures for attaching DS8000® storage to your host with Fibre Channel.

Notes:
Before you attach a host, refer to the following information:

In addition, review the VMware product documentation for the version of VMware that you are using. You can access the VMware documentation at VMware.

LUN limitations: The calculated LUN limitations (Table 1) includes a combination of the following VMware limitations:
  • Maximum of 64 LUNs running I/Os concurrently
  • Less than 2048 paths managed by multipathing
Table 1. Calculated LUN limitations
Number of paths
Maximum number of LUNs
configured on storage system / HBA
1 through 16 64
32 31

VMware configuration maximums can be viewed at: https://configmax.vmware.com/.