lsups

The lsups displays a list of UPSs for the storage system.

Read syntax diagramSkip visual syntax diagram lsups  -s  -l

Parameters

-s
(Optional) Displays the short output for the command. You cannot use the -s and -l parameters together.
-l
(Optional) Displays the long output for the command.

Example: Displaying UPSs of the storage system

dscli> lsups
Output
Date/Time: January 27, 2020 10:18:49 AM MST
IBM DSCLI Version: 0.0.0.0 DS: IBM.2107-75NR641 

ID  Frame  State   Input power  EPLD     Switch
===============================================
2   1      Online  Single-phase Default  Remote   

Location               S/N
===============================
U2831.AE6.75DMC80-E2   0089J283

Output definitions

ID
The enclosure number for the UPS.
Frame
The number of the frame that contains the UPS.
State
The current state of the UPS.
Input power
The type of electric power that is supplied to the storage system.
EPLD
The extended power line disturbance protection feature. This option enables a storage facility to continue operation through a power outage that lasts either 4 seconds or 50 seconds, depending on the following settings:
Default
Operation can continue through a power outage that lasts up to 4 seconds
EPLD (50 sec)
Operation can continue through a power outage that lasts up to 50 seconds.
Switch
The setting of the physical local/remote power control switch that is on the back of the frame. The switch controls whether the system is to be turned off locally or by remote means.
Location
A unique value that is assigned by the storage system to identify the component.
S/N