lsups
The lsups displays a list of UPSs for the storage system.
Parameters
- -s
- (Optional) Displays the short output for the command. You cannot use the -s and -l parameters together.
- -l
- (Optional) Displays the long output for the command.
Example: Displaying UPSs of the storage system
dscli> lsups
Output
Date/Time: January 27, 2020 10:18:49 AM MST
IBM DSCLI Version: 0.0.0.0 DS: IBM.2107-75NR641
ID Frame State Input power EPLD Switch
===============================================
2 1 Online Single-phase Default Remote
Location S/N
===============================
U2831.AE6.75DMC80-E2 0089J283
Output definitions
- ID
- The enclosure number for the UPS.
- Frame
- The number of the frame that contains the UPS.
- State
- The current state of the UPS.
- Input power
- The type of electric power that is supplied to the storage system.
- EPLD
- The extended power line disturbance protection feature. This option enables a storage facility
to continue operation through a power outage that lasts either 4 seconds or 50 seconds, depending on
the following settings:
- Default
- Operation can continue through a power outage that lasts up to 4 seconds
- EPLD (50 sec)
- Operation can continue through a power outage that lasts up to 50 seconds.
- Switch
- The setting of the physical local/remote power control switch that is on the back of the frame. The switch controls whether the system is to be turned off locally or by remote means.
- Location
- A unique value that is assigned by the storage system to identify the component.
- S/N