chsp
The chsp command modifies a storage complex for items such as notification of the Simple Network Management Protocol (SNMP) traps and email problem notification lists in a storage complex.
Notes:
- The Storage Manager server domain is a single storage complex. The storage complex object can be created or deleted only by service personnel.
- The SNMP settings apply to only some types of SNMP notifications (Example: Copy Services).
Parameters
- -snmp on | off
- (Optional) The Simple Network Management Protocol (SNMP) trap notification function sends notifications when a problem occurs on a storage complex. SNMP traps that are generated by the storage complex are sent to the IP address that is specified by the -snmpaddr parameter.
- -snmpaddr new_ip_list
- (Optional) A new SNMP trap destination list. This list consists of one or two IP addresses that
receive SNMP traps that are generated by the storage complex if SNMP is enabled. Note: Multiple IP addresses must be separated with a comma with no space before or after each comma.
- -emailnotify on | off
- (Optional) Email notifications are sent to the designated email addresses when a problem occurs
on a storage complex.
When you enable the -emailnotify and -emailrelay parameters, the email notification is sent directly to the IP address that is associated with the -emailrelayhost hostname parameter. However, if the email relay host name is not specified, the email notification is sent directly to the email relay address.
When email notify is enabled and email relay is disabled, the email notification is sent directly to the specified email address. - -emailaddr new_email_list
- (Optional) The email IP address or addresses where problem notifications are sent. You can
specify two IP addresses. Note: Multiple IP addresses must be separated with a comma with no space before or after the comma.
- -emailrelay on | off
- (Optional) When you enable the -emailrelay and
-emailnotify parameters, the email notification is sent directly to the IP
address that is associated with the -emailrelayhost
new_relay_host_name parameter. However, if the email relay host name is not
specified, the email notification is sent directly to the email relay address.
When email notify is enabled and email relay is disabled, the email notification is sent directly to the specified email address.
- -emailrelayaddr new_relay_ip_list
- (Optional) The email relay IP address list. You can specify two IP addresses.Note: Multiple IP addresses must be separated with a comma with no space before or after the comma.
- -emailrelayhost new_relay_host_name
- (Optional) The new email relay host system name.
- -desc new_sp_description
- (Optional) Your description of the storage complex. This description is limited to 256 byte or 128 double-byte characters.
- -name new_sp_name
- (Optional) The name that you designate for the storage complex. This name is limited to 32 byte or 16 double-byte characters.
- -loginprompt on | off
- (Optional) Whether the login prompt is enabled or disabled.
- -promptmessage new_prompt_message
- (Optional) The detailed prompt message. You cannot modify prompt message if the - loginprompt parameter is set to off.
- -guisuggestions show | hide
- (Optional) Whether suggested tasks are shown or hidden in the task icon at the top right of the Storage Manager GUI. The default is show.
Example: Modifying a storage complex
dscli> chsp -desc "my storage complex"Output:
Storage-complex IBM.2107-75FA120 successfully modified.