EQA9995E REQUIRED TEXT

Explanation

All EQA9995E messages signify that a severe error has occurred in the z/OS® Debugger SVC routine while processing an 0A91 instruction.

Programmer response

  1. Make sure none of the applications you are debugging issue the reserved 0A91 (SVC 145) instruction.
  2. If you have non-IBM® products installed on your system, make sure none of them issue the reserved 0A91 (SVC 145) instruction.
  3. Try running the Dynamic Debug facility IVP (Installation Verification Program). This program can be found in member EQAWIVPS of data set hlq.SEQASAMP.
  4. Have your system support person re-install the z/OS Debugger SVCs using member EQAWISVC of data set hlq.SEQASAMP and then run the IVP (see step 3). If the IVP runs normally, have your support person add hlq.SEQALPA to your system LPA list. This ensures that the z/OS Debugger SVCs are available after the next IPL.
  5. Check the z/OS Debugger web site for any applicable service updates your system might require.
  6. If the problem persists, report the error message text, return code, and reason code to your IBM representative.