Selectively turns on or off switches for groups of monitor
data to be collected by the database manager. Returns the current
state of these switches for the application issuing the call.
Scope
This API can return information for
the database partition server on the instance, or all database partitions
on the instance.
Authorization
One of the following authorities:
- SYSADM
- SYSCTRL
- SYSMAINT
- SYSMON
Required connection
Instance. If there is
no instance attachment, a default instance attachment is created.
To display the settings for a remote instance (or a different
local instance), it is necessary to first attach to that instance.
API include file
db2ApiDf.h
API and data structure syntax
SQL_API_RC SQL_API_FN
db2MonitorSwitches (
db2Uint32 versionNumber,
void * pParmStruct,
struct sqlca * pSqlca);
typedef SQL_STRUCTURE db2MonitorSwitchesData
{
struct sqlm_recording_group *piGroupStates;
void *poBuffer;
db2Uint32 iBufferSize;
db2Uint32 iReturnData;
db2Uint32 iVersion;
db2int32 iNodeNumber;
db2Uint32 *poOutputFormat;
} db2MonitorSwitchesData;
SQL_API_RC SQL_API_FN
db2gMonitorSwitches (
db2Uint32 versionNumber,
void * pParmStruct,
struct sqlca * pSqlca);
typedef SQL_STRUCTURE db2gMonitorSwitchesData
{
struct sqlm_recording_group *piGroupStates;
void *poBuffer;
db2Uint32 iBufferSize;
db2Uint32 iReturnData;
db2Uint32 iVersion;
db2int32 iNodeNumber;
db2Uint32 *poOutputFormat;
} db2gMonitorSwitchesData;
db2MonitorSwitches API parameters
- versionNumber
- Input. Specifies the version and release level of the structure
passed as the second parameter pParmStruct. To
use the structure as described previously, specify db2Version810. If you want to use a different version of this structure, check
the db2ApiDf.h header file in the include directory
for the complete list of supported versions. Ensure that you use the
version of the db2MonitorSwitchesStruct structure
that corresponds to the version number that you specify.
- pParmStruct
- Input. A pointer to the db2MonitorSwitchesStruct structure.
- pSqlca
- Output. A pointer to the sqlca structure.
db2MonitorSwitchesData data structure parameters
- piGroupStates
- Input. A pointer to the sqlm-recording-group structure (defined
in sqlmon.h) containing a list of switches.
- poBuffer
- A pointer to a buffer where the switch state data will be written.
- iBufferSize
- Input. Specifies the size of the output buffer.
- iReturnData
- Input. A flag specifying whether or not the current switch states
should be written to the data buffer pointed to by poBuffer.
- iVersion
- Input. Version ID of the database monitor data to collect. The
database monitor only returns data that was available for the requested
version. Set this parameter to one of the following symbolic constants:
- SQLM_DBMON_VERSION1
- SQLM_DBMON_VERSION2
- SQLM_DBMON_VERSION5
- SQLM_DBMON_VERSION5_2
- SQLM_DBMON_VERSION6
- SQLM_DBMON_VERSION7
- SQLM_DBMON_VERSION8
- SQLM_DBMON_VERSION9
- SQLM_DBMON_VERSION9_5
Note: If SQLM_DBMON_VERSION1 is specified
as the version, the APIs cannot be run remotely.
Note: Constants SQLM_DBMON_VERSION5_2, and earlier, are deprecated and may
be removed in a future release of DB2®.
- iNodeNumber
- Input. The database partition server where the request is to be
sent. Based on this value, the request will be processed for the current
database partition server, all database partition servers or a user
specified database partition server. Valid values are:
- SQLM_CURRENT_NODE
- SQLM_ALL_NODES
- node value
Note: For stand-alone instances SQLM_CURRENT_NODE must be used.
- poOutputFormat
- The format of the stream returned by the server. It will be one
of the following values:
- SQLM_STREAM_STATIC_FORMAT
- Indicates that the switch states are returned in static, pre-Version
7 switch structures.
- SQLM_STREAM_DYNAMIC_FORMAT
- Indicates that the switches are returned in a self-describing
format, similar to the format returned for db2GetSnapshot.
Usage notes
To obtain the status of the
switches at the database manager level, call db2GetSnapshot, specifying SQLMA_DB2 for OBJ_TYPE (get snapshot for database manager).
The timestamp switch is unavailable if iVersion is less than SQLM_DBMON_VERSION8.