You might want to tailor several items in
the installation jobs, such as data set names or library names, to
meet the requirements of your site.
About this task
The changes that are described below are general; that is,
they apply to all the jobs processed by the CLIST. Before you begin
editing, you might want to print or back up the jobs. You can print
the JCL for these jobs by using IEBPTPCH or any other print facility
that is available at your site.
Procedure
To prepare the installation jobs for your site:
- Tailor the jobs to suit the needs of your site.
You
should edit the jobs to conform to any unique requirements that you
might have. Also, you might want to make any minor JCL changes for
items that the ISPF panels did not handle.
- If you specified volume serial numbers on
installation panel DSNTIPA3, examine the volume serial numbers that
are used in the various jobs.
The volume serial number
fields of installation panel DSNTIPA3 enable you to specify up to
five volumes for the data sets that are defined during installation
or migration. If you want to use more than five volumes, specify them
before continuing with installation or migration tasks. If
you specified volume serial numbers on installation panel DSNTIPA3,
the DSNTINST CLIST spreads the data sets across these volumes. If
you use explicit volume serials instead of SMS, adding more volumes
to provide more separation of data sets can help improve system performance
and recoverability. Many of the log data sets are large and easy to
place on separate volumes. The CLIST produces a series of messages
that estimate space for each type of data set that is created during
the installation or migration process.
- Edit the DSNH CLIST if needed.
The DSNH CLIST
allows you to precompile, compile, prelink-edit, link-edit, bind,
and run an application by issuing a single command. You might need
to edit the DSNH CLIST to change values for some of the entries. Verify
that DSNH keyword parameters for all Db2-supported
compilers that your applications use.
- Check the default data set names for the licensed programs
that you have installed.
These defaults are in the parameter
definitions at the beginning of each program. If the names and prefixes
are not correct for your site, change them.
- Check default library names.
If the names
and prefixes are not correct for your site, change them. Ensure that
the data sets exist and are cataloged for BLIB, CLIB, LLIB, and PLIB.
When the DSNH CLIST runs, it creates DBRMLIB and LOAD data sets if
they do not already exist. The DBRMLIB data set is created only if
the DBRMLIB(DEFAULT) is set. The following are the default library
names:
- BLIB(NONE)
- DBRMLIB(DEFAULT) - The DBRM library must be allocated
exclusively when the precompiler writes to it.
Recommendation: Set up a temporary library,
or one per user, rather than trying to share libraries.
- CLIB(NONE)
- LLIB(NONE)
- LOAD(RUNLIB.LOAD) - This library is allocated exclusively when
it is being written.
Recommendation: Set
up a temporary library, or one per user, rather than trying to share
libraries.
- PLIB(NONE)
- Check default processor options.
If you prefer other default options, change them. The default processor options follow:
- CICSOPT(NONE)
- LOPTION(NONE)
- COPTION(NONE)
- PASS(DEFAULT)
- Check print and work space defaults.
If the default allocation sizes are not acceptable for your site, change them. The print and work space defaults follow:
- PSECSPAC(20)
- PSPACE(20)
- WORKUNIT(DEFAULT)
- WSECSPAC(20)
- WSPACE(20)
- Examine the data set names for other products.
Many
data set names for other products appear in the jobs. These names
are shown in the table on panel DSNTIPU. Change them if they are different
at your site.