Controlling CICS connections

Certain CICS® attachment facility commands can be entered from a CICS terminal to control and monitor connections between CICS and Db2.

About this task

Begin general-use programming interface information.

DSNC DISCONNECT
Terminates threads using a specific Db2 plan.
DSNC DISPLAY
Displays thread information or statistics.
DSNC MODIFY
Modifies the maximum number of threads for a transaction or group.
DSNC STOP
Disconnects CICS from Db2.
DSNC STRT
Starts the CICS attachment facility.

CICS command responses are sent to the terminal from which the corresponding command was entered, unless the DSNC DISPLAY command specifies an alternative destination.End general-use programming interface information.