Tailoring installation jobs for a second Db2 subsystem

Before installing a second Db2 subsystem on the same operating system, change the parameter values that are to be used by the installation jobs during the installation.

Procedure

To tailor the installation jobs:

Use the installation CLIST to change parameter values as described in the previous table, as described in Generating tailored Db2 13 installation, migration, or function level activation jobs.
You must change the parameter values listed in the following table. For any parameters that are not in the list, check the values and make appropriate changes.
Table 1. Parameters to change when installing the second subsystem
Installation panel Action
DSNTIPA1 For separate libraries, change LIBRARY DATA SET NAME PREFIX and DATA SET NAME PREFIX.
DSNTIPA2 You must change CATALOG ALIAS. You can change the values for the DATA CLASS, MGMT CLASS, and STOR CLASS fields.
DSNTIPA3 You can change the values for the VOL/SER, DATA CLASS, MGMT CLASS, and STOR CLASS fields.
DSNTIPI Change SUBSYSTEM NAME.
DSNTIPP Change ICF catalog to match the new ICF catalog. Change all passwords.
DSNTIPM Change SUBSYSTEM NAME and SUBSYSTEM PREFIX.
DSNTIPL Change data set names and prefixes.
DSNTIPA Change data set names and prefixes.
DSNTIPS Change data set names and prefixes.
DSNTIPR Change names and password.
DSNTIPC Check values of DSMAX, EDMSTMTC, EDMDBDC, EDM_SKELETON_POOL, MAXSORT_IN_MEMORY, SRTPOOL, and MAXRBLK; no other changes can be made.