Start of change

DSNU537I csect-name object-type object-qualifier.object-name IS NOT ALLOWED IN THE LIST

Explanation

The RECOVER, COPY, or LISTDEF utility found a directory or catalog table space in a list with other table spaces or other indexes.

csect-name
The name of the control section that issued the message.
object-type
The type of object.
object-qualifier.object-name
One of the qualified object names that is not compatible with other objects in the same list.

For COPY, you can specify the following table spaces in a list with only the related index spaces and not with other table spaces or index spaces:

  • DSNDB01.SYSUTILX
  • DSNDB06.SYSTSCPY
  • DSNDB01.SYSLGRNX
  • FL 501 DSNDB06.SYSTSUTL and FL 504 DSNDB06.SYSTSOEV
  • FL 509 DSNDB01.SYSTSUTM and DSNDB01.SYSTSUTX

Start of changeFL 504 Note that the utility history tables spaces (DSNDB06.SYSTSUTL and DSNDB06.SYSTSOEV) are listed in the same bullet, because they can be copied together in the same list, along with their index spaces. End of change

Start of changeFL 509 Similarly, utility tables spaces DSNDB01.SYSTSUTM and DSNDB01.SYSTSUTX are listed in the same bullet, because they can be copied together in the same list, along with their index spaces. End of change

For RECOVER, you can specify the following table spaces in a list with only the related index spaces and not with other table spaces or index spaces:

  • DSNDB01.SYSUTILX
  • DSNDB01.DBD01
  • DSNDB01.SYSDBDXA
  • DSNDB06.SYSTSCPY
  • DSNDB01.SYSLGRNX
  • DSNDB06.SYSTSSTG and DSNDB06.SYSTSVOL
  • FL 501 DSNDB06.SYSTSUTL and FL 504 DSNDB06.SYSTSOEV
  • FL 509 DSNDB01.SYSTSUTM and DSNDB01.SYSTSUTX

The pairs of catalog table spaces listed in the same bullet can be recovered together with their indexes in the same list. Directory and catalog table spaces must be recovered in a particular order, because the recovery of some objects depends on information in other objects. Indexes can be specified with their associated directory or catalog table space in a list.

For LISTDEF, SYSUTILX objects (the SYSUTILX, SYSTSUTM, and SYSTSUTX table spaces, the SYSUTIL table, and the SYSUTILX table) cannot be specified with other, non-SYSUTILX, objects in the same LISTDEF list.

System action

The utility job terminates.

User response

Remove the directory and catalog object names from the list. Then, submit the utility again.

Severity

8 (error)

End of change