DSNR010I AN ERROR OCCURRED IN THE RURE STATUS TABLE SORT/TRANSLATE MODULE (DSNRUSOR), THE ERROR LOCATION CODE = xxxx

Explanation

There was an error in processing the RURE display table. One of these ERROR LOCATION CODES tells what function the module was attempting to perform:
X'0001'
Trace entry to the module
X'0002'
Sort the recoverable UR display table
X'0003'
Translate the recoverable UR table
X'0004'
Convert the store clock value for display
X'0005'
Trace exit from the module

System action

The system continues to restart but the RESTART... STATUS TABLE is not displayed.

Operator response

Save the console output and inform the system programmer.

System programmer response

Use the error code in the message to complete the problem description.

Problem determination

The ERROR CODE tells the problem area and should be used in the problem description. A record was added to the SYS1.LOGREC that contains the PSW and module at the time of the error. This error indicates an application program check of some type.