DSNR010I AN ERROR OCCURRED IN THE RURE STATUS TABLE SORT/TRANSLATE MODULE (DSNRUSOR), THE ERROR LOCATION CODE = xxxx
Explanation
There was an error in processing the RURE display
table. One of these ERROR LOCATION CODES tells what function the module
was attempting to perform:
- X'0001'
- Trace entry to the module
- X'0002'
- Sort the recoverable UR display table
- X'0003'
- Translate the recoverable UR table
- X'0004'
- Convert the store clock value for display
- X'0005'
- Trace exit from the module
System action
The system continues to restart but the RESTART... STATUS TABLE is not displayed.
Operator response
Save the console output and inform the system programmer.
System programmer response
Use the error code in the message to complete the problem description.
Problem determination
The ERROR CODE tells the problem area and should be used in the problem description. A record was added to the SYS1.LOGREC that contains the PSW and module at the time of the error. This error indicates an application program check of some type.